These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
320 related items for PubMed ID: 22625191
1. Structural integrity of balloon-expandable stents after transcatheter aortic valve replacement: assessment by multidetector computed tomography. Willson AB, Webb JG, Gurvitch R, Wood DA, Toggweiler S, Binder R, Freeman M, Madden M, Hague C, Leipsic J. JACC Cardiovasc Interv; 2012 May; 5(5):525-532. PubMed ID: 22625191 [Abstract] [Full Text] [Related]
2. Impact of post-implant SAPIEN XT geometry and position on conduction disturbances, hemodynamic performance, and paravalvular regurgitation. Binder RK, Webb JG, Toggweiler S, Freeman M, Barbanti M, Willson AB, Alhassan D, Hague CJ, Wood DA, Leipsic J. JACC Cardiovasc Interv; 2013 May; 6(5):462-8. PubMed ID: 23702010 [Abstract] [Full Text] [Related]
3. A Strategy of Underexpansion and Ad Hoc Post-Dilation of Balloon-Expandable Transcatheter Aortic Valves in Patients at Risk of Annular Injury: Favorable Mid-Term Outcomes. Tan JS, Leipsic J, Perlman G, Stub D, Dvir D, Hansson NC, Norgaard BL, Blanke P, Cheung A, Ye J, Thompson CR, Moss RR, Lauck S, Wood D, Webb J. JACC Cardiovasc Interv; 2015 Nov; 8(13):1727-32. PubMed ID: 26476612 [Abstract] [Full Text] [Related]
4. Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the Sapien 3: a comparison with the Sapien XT. Yang TH, Webb JG, Blanke P, Dvir D, Hansson NC, Nørgaard BL, Thompson CR, Thomas M, Wendler O, Vahanian A, Himbert D, Kodali SK, Hahn RT, Thourani VH, Schymik G, Precious B, Berger A, Wood DA, Pibarot P, Rodés-Cabau J, Jaber WA, Leon MB, Walther T, Leipsic J. JACC Cardiovasc Interv; 2015 Mar; 8(3):462-471. PubMed ID: 25790764 [Abstract] [Full Text] [Related]
5. Assessment of the geometric interaction between the Lotus transcatheter aortic valve prosthesis and the native ventricular aortic interface by 320-multidetector computed tomography. Gooley RP, Cameron JD, Meredith IT. JACC Cardiovasc Interv; 2015 Apr 27; 8(5):740-9. PubMed ID: 25946448 [Abstract] [Full Text] [Related]
6. Medium-term CT evaluation of stent geometry, integrity, and valve function of the Edwards SAPIEN transcatheter heart valve in the pulmonary position. Muller B, Ghawi H, Heitschmidt MG, Fogg L, Hibbeln J, Hijazi ZM, Kenny D. Catheter Cardiovasc Interv; 2016 Feb 15; 87(3):E97-103. PubMed ID: 26152363 [Abstract] [Full Text] [Related]
7. Comparison of SAPIEN 3 and SAPIEN XT transcatheter heart valve stent-frame expansion: evaluation using multi-slice computed tomography. Kazuno Y, Maeno Y, Kawamori H, Takahashi N, Abramowitz Y, Babak H, Kashif M, Chakravarty T, Nakamura M, Cheng W, Friedman J, Berman D, Makkar RR, Jilaihawi H. Eur Heart J Cardiovasc Imaging; 2016 Sep 15; 17(9):1054-62. PubMed ID: 27002141 [Abstract] [Full Text] [Related]
8. Transcatheter aortic valve replacement with the SAPIEN 3: a new balloon-expandable transcatheter heart valve. Binder RK, Rodés-Cabau J, Wood DA, Mok M, Leipsic J, De Larochellière R, Toggweiler S, Dumont E, Freeman M, Willson AB, Webb JG. JACC Cardiovasc Interv; 2013 Mar 15; 6(3):293-300. PubMed ID: 23517842 [Abstract] [Full Text] [Related]
9. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves. Stähli BE, Nguyen-Kim TD, Gebhard C, Erhart L, Frauenfelder T, Tanner FC, Falk V, Landmesser U, Nietlispach F, Lüscher TF, Maier W, Binder RK. J Heart Valve Dis; 2015 Jan 15; 24(1):10-21. PubMed ID: 26182615 [Abstract] [Full Text] [Related]
10. Three-dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on postprocedural paravalvular aortic regurgitation. Hansson NC, Thuesen L, Hjortdal VE, Leipsic J, Andersen HR, Poulsen SH, Webb JG, Christiansen EH, Rasmussen LE, Krusell LR, Terp K, Klaaborg KE, Tang M, Lassen JF, Bøtker HE, Nørgaard BL. Catheter Cardiovasc Interv; 2013 Nov 15; 82(6):977-86. PubMed ID: 23703899 [Abstract] [Full Text] [Related]
11. Underexpansion and ad hoc post-dilation in selected patients undergoing balloon-expandable transcatheter aortic valve replacement. Barbanti M, Leipsic J, Binder R, Dvir D, Tan J, Freeman M, Norgaard B, Hansson N, Cheung A, Ye J, Yang TH, Maryniak K, Raju R, Thompson A, Blanke P, Lauck S, Wood D, Webb J. J Am Coll Cardiol; 2014 Mar 18; 63(10):976-81. PubMed ID: 24211502 [Abstract] [Full Text] [Related]
12. Valve-in-Valve Procedures in Failing Biological Xenografts Using a Novel Balloon-Expandable Device: Experience in Aortic, Mitral, and Tricuspid Positions. Schaefer A, Conradi L, Seiffert M, Lubos E, Blankenberg S, Reichenspurner H, Schaefer U, Treede H. Thorac Cardiovasc Surg; 2016 Aug 18; 64(5):366-73. PubMed ID: 26277078 [Abstract] [Full Text] [Related]
13. Balloon-expandable prostheses for transcatheter aortic valve replacement. Ribeiro HB, Urena M, Allende R, Amat-Santos IJ, Rodés-Cabau J. Prog Cardiovasc Dis; 2014 Aug 18; 56(6):583-95. PubMed ID: 24838134 [Abstract] [Full Text] [Related]
14. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement. Freeman M, Webb JG, Willson AB, Wheeler M, Blanke P, Moss RR, Thompson CR, Munt B, Norgaard BL, Yang TH, Min JK, Poulsen S, Hansson NC, Binder RK, Toggweiler S, Hague C, Wood DA, Pibarot P, Leipsic J. J Cardiovasc Comput Tomogr; 2013 Aug 18; 7(4):248-55. PubMed ID: 24148778 [Abstract] [Full Text] [Related]
15. Applicability of next generation balloon-expandable transcatheter heart valves in aortic annuli exceeding formally approved dimensions. Schaefer A, Linder M, Treede H, Deuschl F, Schofer N, Seiffert M, Schneeberger Y, Blankenberg S, Reichenspurner H, Schaefer U, Conradi L. Clin Res Cardiol; 2016 Jul 18; 105(7):585-91. PubMed ID: 26680213 [Abstract] [Full Text] [Related]
16. Dual source computed tomography based analysis of stent performance, its association with valvular calcification and residual aortic regurgitation after implantation of a balloon-expandable transcatheter heart valve. Gerstmeyer J, Kütting M, Fujita B, Schuhbäck A, Arnold M, Börgermann J, Achenbach S, Steinseifer U, Gummert J, Ensminger S. Interact Cardiovasc Thorac Surg; 2017 Apr 01; 24(4):506-513. PubMed ID: 28108576 [Abstract] [Full Text] [Related]
17. Incidence, predictive factors and haemodynamic consequences of acute stent recoil following transcatheter aortic valve implantation with a balloon-expandable valve. Nombela-Franco L, Ribeiro HB, Urena M, Pasian S, Allende R, Doyle D, Delarochellière R, Delarochellière H, Laflamme L, Laflamme J, Jerez-Valero M, Côté M, Pibarot P, Larose E, Dumont E, Rodés-Cabau J. EuroIntervention; 2014 Apr 01; 9(12):1398-406. PubMed ID: 24064535 [Abstract] [Full Text] [Related]
18. First-in-man transfemoral transcatheter aortic valve replacement with the 29 mm Edwards SAPIEN XT valve. Freeman M, Rodés-Cabau J, Urena M, DeLarochelliere R, Dumont E, Masson JB, Willson AB, Binder RK, Toggweiler S, Leipsic J, Wood DA, Webb JG. Catheter Cardiovasc Interv; 2013 Oct 01; 82(4):664-70. PubMed ID: 22744829 [Abstract] [Full Text] [Related]
19. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. Willson AB, Webb JG, Labounty TM, Achenbach S, Moss R, Wheeler M, Thompson C, Min JK, Gurvitch R, Norgaard BL, Hague CJ, Toggweiler S, Binder R, Freeman M, Poulter R, Poulsen S, Wood DA, Leipsic J. J Am Coll Cardiol; 2012 Apr 03; 59(14):1287-94. PubMed ID: 22365423 [Abstract] [Full Text] [Related]
20. Transcatheter valve-in-valve implantation for failed balloon-expandable transcatheter aortic valves. Toggweiler S, Wood DA, Rodés-Cabau J, Kapadia S, Willson AB, Ye J, Cheung A, Leipsic J, Binder RK, Gurvitch R, Freeman M, Thompson CR, Svensson LG, Dumont E, Tuzcu EM, Webb JG. JACC Cardiovasc Interv; 2012 May 03; 5(5):571-577. PubMed ID: 22625197 [Abstract] [Full Text] [Related] Page: [Next] [New Search]