These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
827 related items for PubMed ID: 22839515
1. [Cryoballoon ablation for pulmonary vein isolation to treat atrial fibrillation: first experience in Russian Federation]. Lebedev DS, Mikhaĭlov EN, Orshanskaia VS, Kolunin GV, Kharats VE, Pavlov AV, Kuznetsov VA, Shliakhto EV. Kardiologiia; 2012; 52(4):38-48. PubMed ID: 22839515 [Abstract] [Full Text] [Related]
2. Evaluation of safety and the success rate of cryoballoon ablation of the pulmonary vein ostia in patients with atrial fibrillation--a preliminary report. Koźluk E, Gaj S, Piatkowska A, Kiliszek M, Lodziński P, Dabrowski P, Zukowska M, Stefańczyk P, Kleinrok A, Opolski G. Kardiol Pol; 2010 Feb; 68(2):175-80. PubMed ID: 20301026 [Abstract] [Full Text] [Related]
3. Regular atrial tachycardias developing after cryoballoon pulmonary vein isolation: incidence, characteristics, and predictors. Mikhaylov EN, Bhagwandien R, Janse PA, Theuns DA, Szili-Torok T. Europace; 2013 Dec; 15(12):1710-7. PubMed ID: 23689485 [Abstract] [Full Text] [Related]
4. Efficacy of pulmonary vein isolation by cryoballoon ablation in patients with paroxysmal atrial fibrillation. Klein G, Oswald H, Gardiwal A, Lüsebrink U, Lissel C, Yu H, Drexler H. Heart Rhythm; 2008 Jun; 5(6):802-6. PubMed ID: 18534363 [Abstract] [Full Text] [Related]
5. One-year follow-up after second-generation cryoballoon ablation for atrial fibrillation in a large cohort of patients: a single-centre experience. Irfan G, de Asmundis C, Mugnai G, Poelaert J, Verborgh C, Umbrain V, Beckers S, Hacioglu E, Hunuk B, Velagic V, Stroker E, Brugada P, Chierchia GB. Europace; 2016 Jul; 18(7):987-93. PubMed ID: 26705562 [Abstract] [Full Text] [Related]
6. Arrhythmia-free survival and pulmonary vein reconnection patterns after second-generation cryoballoon and contact-force radiofrequency pulmonary vein isolation. Buist TJ, Adiyaman A, Smit JJJ, Ramdat Misier AR, Elvan A. Clin Res Cardiol; 2018 Jun; 107(6):498-506. PubMed ID: 29411114 [Abstract] [Full Text] [Related]
7. Cryoballoon versus radiofrequency for pulmonary vein re-isolation after a failed initial ablation procedure in patients with paroxysmal atrial fibrillation. Pokushalov E, Romanov A, Artyomenko S, Baranova V, Losik D, Bairamova S, Karaskov A, Mittal S, Steinberg JS. J Cardiovasc Electrophysiol; 2013 Mar; 24(3):274-9. PubMed ID: 23210695 [Abstract] [Full Text] [Related]
8. Selective ablation or isolation of all pulmonary veins in atrial fibrillation -- when and for whom? Walczak F, Szumowski L, Urbanek P, Szufladowicz E, Derejko P, Kułakowski P, Baranowski R, Bodalski R, Kepski R, Zagrodzka M, Onish K, Bestry I, Konka M, Kuśnierczyk B, Maryniak A. Kardiol Pol; 2006 Jan; 64(1):26-35; discussion 36-7. PubMed ID: 16444625 [Abstract] [Full Text] [Related]
9. Radiofrequency catheter ablation for redo procedures after pulmonary vein isolation with the cryoballoon technique : Long-term outcome. Kettering K, Gramley F. Herzschrittmacherther Elektrophysiol; 2017 Jun; 28(2):225-231. PubMed ID: 28243805 [Abstract] [Full Text] [Related]
10. Efficacy of cryoballoon ablation in patients with paroxysmal atrial fibrillation without time to pulmonary vein isolation assessment. Stabile G, Tondo C, Curnis A, Lunati M, Manfrin M, Molon G, Sciarra L, Mantica M, Iacopino S, Arena G, Landolina M, Arestia A, Verlato R. Int J Cardiol; 2018 Dec 01; 272():118-122. PubMed ID: 30037629 [Abstract] [Full Text] [Related]
11. Recurrence of paroxysmal atrial fibrillation after cryoisolation of the pulmonary veins. Is a "redo" procedure using the cryoballoon useful? Schade A, Langbein A, Spehl S, Barth S, Deneke T, Groschup G, Koller ML, Schumacher B. J Interv Card Electrophysiol; 2013 Apr 01; 36(3):287-95; discussion 295. PubMed ID: 23132349 [Abstract] [Full Text] [Related]
12. Value of high-resolution mapping in optimizing cryoballoon ablation of atrial fibrillation. Conte G, Soejima K, de Asmundis C, Chierchia GB, Badini M, Miwa Y, Caputo ML, Özkartal T, Maffessanti F, Sieira J, Degreef Y, Stroker E, Regoli F, Moccetti T, Brugada P, Auricchio A. Int J Cardiol; 2018 Nov 01; 270():136-142. PubMed ID: 29929934 [Abstract] [Full Text] [Related]
13. Five-year efficacy of pulmonary vein antrum isolation as a primary ablation strategy for atrial fibrillation: a single-centre cohort study. Teunissen C, Kassenberg W, van der Heijden JF, Hassink RJ, van Driel VJ, Zuithoff NP, Doevendans PA, Loh P. Europace; 2016 Sep 01; 18(9):1335-42. PubMed ID: 26838694 [Abstract] [Full Text] [Related]
14. Impact of Pulmonary Vein Anatomy on Long-term Outcome of Cryoballoon Ablation for Atrial Fibrillation. Huang SW, Jin Q, Zhang N, Ling TY, Pan WQ, Lin CJ, Luo QZ, Han YX, Wu LQ. Curr Med Sci; 2018 Apr 01; 38(2):259-267. PubMed ID: 30074184 [Abstract] [Full Text] [Related]
15. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial. Packer DL, Kowal RC, Wheelan KR, Irwin JM, Champagne J, Guerra PG, Dubuc M, Reddy V, Nelson L, Holcomb RG, Lehmann JW, Ruskin JN, STOP AF Cryoablation Investigators. J Am Coll Cardiol; 2013 Apr 23; 61(16):1713-23. PubMed ID: 23500312 [Abstract] [Full Text] [Related]
16. Catheter ablation using the third-generation cryoballoon provides an enhanced ability to assess time to pulmonary vein isolation facilitating the ablation strategy: Short- and long-term results of a multicenter study. Aryana A, Kowalski M, O'Neill PG, Koo CH, Lim HW, Khan A, Hokanson RB, Bowers MR, Kenigsberg DN, Ellenbogen KA, Cryo-DOSING Investigators. Heart Rhythm; 2016 Dec 23; 13(12):2306-2313. PubMed ID: 27503480 [Abstract] [Full Text] [Related]
17. Early identification and treatment of PV re-connections: role of observation time and impact on clinical results of atrial fibrillation ablation. Wang XH, Liu X, Sun YM, Gu JN, Shi HF, Zhou L, Hu W. Europace; 2007 Jul 23; 9(7):481-6. PubMed ID: 17522081 [Abstract] [Full Text] [Related]