These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
128 related items for PubMed ID: 22868616
1. Catastrophic fracture of a stable metal acetabular component. Papaliodis DN, Uhl RL, Fuchs MD. Orthopedics; 2012 Aug 01; 35(8):e1260-3. PubMed ID: 22868616 [Abstract] [Full Text] [Related]
2. Massive wear and metallosis of an Acetabular Cup System presenting as pseudodislocation. Sathappan SS, Wee J, Ginat D, Meere P. Orthopedics; 2009 Jun 01; 32(6):449. PubMed ID: 19634809 [Abstract] [Full Text] [Related]
3. [Early primary total hip arthroplasty for acetabular fractures in elderly patients]. Simko P, Braunsteiner T, Vajcziková S. Acta Chir Orthop Traumatol Cech; 2006 Aug 01; 73(4):275-82. PubMed ID: 17026887 [Abstract] [Full Text] [Related]
4. Complete acetabular cup revision versus isolated liner exchange for polyethylene wear and osteolysis without loosening in cementless total hip arthroplasty. Koh KH, Moon YW, Lim SJ, Lee HI, Shim JW, Park YS. Arch Orthop Trauma Surg; 2011 Nov 01; 131(11):1591-600. PubMed ID: 21687959 [Abstract] [Full Text] [Related]
7. Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6-10 years follow-up. Zwartelé RE, Olsthoorn PG, Pöll RG, Brand R, Doets HC. Arch Orthop Trauma Surg; 2008 Dec 01; 128(12):1379-86. PubMed ID: 18758793 [Abstract] [Full Text] [Related]
8. [Causes and managements of acetabular fracture during primary total hip arthroplasty]. Song L, Zhang T, Yu J, Ren K. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Aug 01; 25(8):968-71. PubMed ID: 21923027 [Abstract] [Full Text] [Related]
13. [Reconstruction of the acetabulum during replacement of the aseptically loosened polyethylene cup]. Koudela K, Malotín T. Acta Chir Orthop Traumatol Cech; 2001 Aug 01; 68(3):162-7. PubMed ID: 11706538 [Abstract] [Full Text] [Related]
14. Unexpected finding of a fractured metal prosthetic femoral head in a nonmodular implant during revision total hip arthroplasty. Giori NJ. J Arthroplasty; 2010 Jun 01; 25(4):659.e13-5. PubMed ID: 20022458 [Abstract] [Full Text] [Related]
15. Open reduction internal fixation and primary total hip arthroplasty of selected acetabular fractures. Boraiah S, Ragsdale M, Achor T, Zelicof S, Asprinio DE. J Orthop Trauma; 2009 Apr 01; 23(4):243-8. PubMed ID: 19318866 [Abstract] [Full Text] [Related]
16. Unsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis. Nieuwenhuis JJ, Malefijt Jde W, Hendriks JC, Gosens T, Bonnet M. Acta Orthop Belg; 2005 Jun 01; 71(3):294-302. PubMed ID: 16035702 [Abstract] [Full Text] [Related]