These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


222 related items for PubMed ID: 22868797

  • 21. Thromboelastographic evaluation of coagulative profiles in pig-to-monkey kidney xenotransplantation.
    Spiezia L, Boldrin M, Radu C, Bulato C, Bertini D, Bon M, Campello E, Vadori M, Galli C, Gavasso S, Nottle MB, Cowan PJ, Cozzi E, Simioni P.
    Xenotransplantation; 2013; 20(2):89-99. PubMed ID: 23406330
    [Abstract] [Full Text] [Related]

  • 22. Comparison of whole blood fibrin-based clot tests in thrombelastography and thromboelastometry.
    Solomon C, Sørensen B, Hochleitner G, Kashuk J, Ranucci M, Schöchl H.
    Anesth Analg; 2012 Apr; 114(4):721-30. PubMed ID: 22314689
    [Abstract] [Full Text] [Related]

  • 23.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 24. Whole blood rotation thromboelastometry (ROTEM®) profiles in subjects with non-neoplastic portal vein thrombosis.
    Rossetto V, Spiezia L, Senzolo M, Rodriguez-Castro KI, Maggiolo S, Simioni P.
    Thromb Res; 2013 Aug; 132(2):e131-4. PubMed ID: 23810655
    [Abstract] [Full Text] [Related]

  • 25.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 26.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 27. Utility of interim ROTEM(®) values of clot strength, A5 and A10, in predicting final assessment of coagulation status in severely injured battle patients.
    Woolley T, Midwinter M, Spencer P, Watts S, Doran C, Kirkman E.
    Injury; 2013 May; 44(5):593-9. PubMed ID: 22487164
    [Abstract] [Full Text] [Related]

  • 28. Intrarater and interrater variability of point of care coagulation testing using the ROTEM delta.
    Mauch J, Spielmann N, Hartnack S, Madjdpour C, Kutter AP, Bettschart-Wolfensberger R, Weiss M, Haas T.
    Blood Coagul Fibrinolysis; 2011 Dec; 22(8):662-6. PubMed ID: 21822125
    [Abstract] [Full Text] [Related]

  • 29. Coagulation assessment by rotation thrombelastometry in normal pregnancy.
    Huissoud C, Carrabin N, Benchaib M, Fontaine O, Levrat A, Massignon D, Touzet S, Rudigoz RC, Berland M.
    Thromb Haemost; 2009 Apr; 101(4):755-61. PubMed ID: 19350122
    [Abstract] [Full Text] [Related]

  • 30. [Manageability and potential for haemostasis monitoring by near-patient modified thromboelastometer (Rotem) in intensive care unit].
    Savry C, Quinio P, Lefèvre F, Schmitt F.
    Ann Fr Anesth Reanim; 2005 Jun; 24(6):607-16. PubMed ID: 15922540
    [Abstract] [Full Text] [Related]

  • 31. Monitoring fibrinolysis in whole blood by viscoelastic instruments: a comparison of ROTEM and ReoRox.
    Nilsson CU, Tynngård N, Reinstrup P, Engström M.
    Scand J Clin Lab Invest; 2013 Sep; 73(6):457-65. PubMed ID: 23767889
    [Abstract] [Full Text] [Related]

  • 32. Are the point-of-care diagnostics MULTIPLATE and ROTEM valid in the setting of high concentrations of heparin and its reversal with protamine?
    Gertler R, Wiesner G, Tassani-Prell P, Braun SL, Martin K.
    J Cardiothorac Vasc Anesth; 2011 Dec; 25(6):981-6. PubMed ID: 21315618
    [Abstract] [Full Text] [Related]

  • 33. Coagulation function of stored whole blood is preserved for 14 days in austere conditions: A ROTEM feasibility study during a Norwegian antipiracy mission and comparison to equal ratio reconstituted blood.
    Strandenes G, Austlid I, Apelseth TO, Hervig TA, Sommerfelt-Pettersen J, Herzig MC, Cap AP, Pidcoke HF, Kristoffersen EK.
    J Trauma Acute Care Surg; 2015 Jun; 78(6 Suppl 1):S31-8. PubMed ID: 26002261
    [Abstract] [Full Text] [Related]

  • 34. Smartphone monitoring of pneumatic tube system-induced sample hemolysis.
    Mullins GR, Harrison JH, Bruns DE.
    Clin Chim Acta; 2016 Nov 01; 462():1-5. PubMed ID: 27553857
    [Abstract] [Full Text] [Related]

  • 35. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?
    Phelan MP, Reineks EZ, Hustey FM, Berriochoa JP, Podolsky SR, Meldon S, Schold JD, Chamberlin J, Procop GW.
    West J Emerg Med; 2016 Sep 01; 17(5):557-60. PubMed ID: 27625719
    [Abstract] [Full Text] [Related]

  • 36. Validation of rotational thromboelastometry during cardiopulmonary bypass: A prospective, observational in-vivo study.
    Gronchi F, Perret A, Ferrari E, Marcucci CM, Flèche J, Crosset M, Schoettker P, Marcucci C.
    Eur J Anaesthesiol; 2014 Feb 01; 31(2):68-75. PubMed ID: 23867776
    [Abstract] [Full Text] [Related]

  • 37.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 38. Are TEG(®) results in healthy blood donors affected by the transport of blood samples in a pneumatic tube system?
    Espinosa A, Ruckert A, Navarro J, Videm V, Sletta BV.
    Int J Lab Hematol; 2016 Aug 01; 38(4):e73-6. PubMed ID: 27174730
    [No Abstract] [Full Text] [Related]

  • 39. Effects of a pneumatic tube system on routine and novel hematology and coagulation parameters in healthy volunteers.
    Kratz A, Salem RO, Van Cott EM.
    Arch Pathol Lab Med; 2007 Feb 01; 131(2):293-6. PubMed ID: 17284116
    [Abstract] [Full Text] [Related]

  • 40. The pneumatic tube system does not affect complete blood count results; a validation study at a tertiary care hospital.
    Al-Riyami AZ, Al-Khabori M, Al-Hadhrami RM, Al-Azwani IS, Davis HM, Al-Farsi KS, Alkindi SS, Daar SF.
    Int J Lab Hematol; 2014 Oct 01; 36(5):514-20. PubMed ID: 24373139
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 12.