These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


259 related items for PubMed ID: 22931575

  • 1. [Comparative adaptation of crowns of selective laser melting and wax-lost-casting method].
    Li GQ, Shen QY, Gao JH, Wu XY, Chen L, Dai WA.
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2012 Jul; 47(7):427-30. PubMed ID: 22931575
    [Abstract] [Full Text] [Related]

  • 2. Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology.
    Huang Z, Zhang L, Zhu J, Zhang X.
    J Prosthet Dent; 2015 Jun; 113(6):623-7. PubMed ID: 25794918
    [Abstract] [Full Text] [Related]

  • 3. Effect of production method on surface roughness, marginal and internal fit, and retention of cobalt-chromium single crowns.
    Lövgren N, Roxner R, Klemendz S, Larsson C.
    J Prosthet Dent; 2017 Jul; 118(1):95-101. PubMed ID: 28024818
    [Abstract] [Full Text] [Related]

  • 4. Effects of repeated firing on the marginal accuracy of Co-Cr copings fabricated by selective laser melting.
    Zeng L, Zhang Y, Liu Z, Wei B.
    J Prosthet Dent; 2015 Feb; 113(2):135-9. PubMed ID: 25444279
    [Abstract] [Full Text] [Related]

  • 5. The marginal fit of selective laser melting-fabricated metal crowns: an in vitro study.
    Xu D, Xiang N, Wei B.
    J Prosthet Dent; 2014 Dec; 112(6):1437-40. PubMed ID: 25001421
    [Abstract] [Full Text] [Related]

  • 6. Selective laser sintering versus conventional lost-wax casting for single metal copings: A systematic review and meta-analysis.
    Yang J, Li H, Xu L, Wang Y.
    J Prosthet Dent; 2022 Nov; 128(5):897-904. PubMed ID: 33789799
    [Abstract] [Full Text] [Related]

  • 7. Internal fit of single crowns produced by CAD-CAM and lost-wax metal casting technique assessed by the triple-scan protocol.
    Dahl BE, Rønold HJ, Dahl JE.
    J Prosthet Dent; 2017 Mar; 117(3):400-404. PubMed ID: 27692584
    [Abstract] [Full Text] [Related]

  • 8. Marginal fit of metal-ceramic crowns fabricated by using a casting and two selective laser melting processes before and after ceramic firing.
    Hong MH, Min BK, Lee DH, Kwon TY.
    J Prosthet Dent; 2019 Nov; 122(5):475-481. PubMed ID: 30982615
    [Abstract] [Full Text] [Related]

  • 9. Comparison of internal fit between implant abutments and cast metal crowns vs laser-sintered crowns.
    Kiliçarslan MA, Özkan P, Uludag B, Mumcu E.
    J Contemp Dent Pract; 2014 Jul 01; 15(4):428-32. PubMed ID: 25576108
    [Abstract] [Full Text] [Related]

  • 10. Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns.
    Ucar Y, Akova T, Akyil MS, Brantley WA.
    J Prosthet Dent; 2009 Oct 01; 102(4):253-9. PubMed ID: 19782828
    [Abstract] [Full Text] [Related]

  • 11. Evaluation of marginal/internal fit of chrome-cobalt crowns: Direct laser metal sintering versus computer-aided design and computer-aided manufacturing.
    Gunsoy S, Ulusoy M.
    Niger J Clin Pract; 2016 Oct 01; 19(5):636-44. PubMed ID: 27538553
    [Abstract] [Full Text] [Related]

  • 12. An in vitro comparison of vertical marginal gaps of CAD/CAM titanium and conventional cast restorations.
    Tan PL, Gratton DG, Diaz-Arnold AM, Holmes DC.
    J Prosthodont; 2008 Jul 01; 17(5):378-83. PubMed ID: 18355167
    [Abstract] [Full Text] [Related]

  • 13. A microcomputed tomography evaluation of the marginal fit of cobalt-chromium alloy copings fabricated by new manufacturing techniques and alloy systems.
    Kim EH, Lee DH, Kwon SM, Kwon TY.
    J Prosthet Dent; 2017 Mar 01; 117(3):393-399. PubMed ID: 27677219
    [Abstract] [Full Text] [Related]

  • 14. Accuracy of CAD-CAM milling versus conventional lost-wax casting for single metal copings: A systematic review and meta-analysis.
    Yang J, Li H.
    J Prosthet Dent; 2024 Jul 01; 132(1):51-58. PubMed ID: 35788274
    [Abstract] [Full Text] [Related]

  • 15. Internal adaptation of cobalt-chromium posts fabricated by selective laser melting technology.
    Liu W, Qing H, Pei X, Wang J.
    J Prosthet Dent; 2019 Mar 01; 121(3):455-460. PubMed ID: 30126687
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 18. Clinical marginal and internal adaptation of CAD/CAM milling, laser sintering, and cast metal ceramic crowns.
    Tamac E, Toksavul S, Toman M.
    J Prosthet Dent; 2014 Oct 01; 112(4):909-13. PubMed ID: 24819532
    [Abstract] [Full Text] [Related]

  • 19. Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology.
    Quante K, Ludwig K, Kern M.
    Dent Mater; 2008 Oct 01; 24(10):1311-5. PubMed ID: 18384869
    [Abstract] [Full Text] [Related]

  • 20.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 13.