These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


962 related items for PubMed ID: 23040577

  • 1. Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve.
    Urena M, Mok M, Serra V, Dumont E, Nombela-Franco L, DeLarochellière R, Doyle D, Igual A, Larose E, Amat-Santos I, Côté M, Cuéllar H, Pibarot P, de Jaegere P, Philippon F, Garcia del Blanco B, Rodés-Cabau J.
    J Am Coll Cardiol; 2012 Oct 30; 60(18):1743-52. PubMed ID: 23040577
    [Abstract] [Full Text] [Related]

  • 2. Impact of new-onset persistent left bundle branch block on late clinical outcomes in patients undergoing transcatheter aortic valve implantation with a balloon-expandable valve.
    Urena M, Webb JG, Cheema A, Serra V, Toggweiler S, Barbanti M, Cheung A, Ye J, Dumont E, DeLarochellière R, Doyle D, Al Lawati HA, Peterson M, Chisholm R, Igual A, Ribeiro HB, Nombela-Franco L, Philippon F, Garcia Del Blanco B, Rodés-Cabau J.
    JACC Cardiovasc Interv; 2014 Feb 30; 7(2):128-136. PubMed ID: 24440024
    [Abstract] [Full Text] [Related]

  • 3. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: initial single centre experience.
    Czerwińska K, Hryniewiecki T, Oręziak A, Dąbrowski M, Michałowska I, Witkowski A, Demkow M, Stępińska J, Orłowska Baranowska E, Rużyłło W.
    Kardiol Pol; 2012 Feb 30; 70(2):121-8. PubMed ID: 22427074
    [Abstract] [Full Text] [Related]

  • 4.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 5. Electrocardiographic changes and clinical outcomes after transapical aortic valve implantation.
    Gutiérrez M, Rodés-Cabau J, Bagur R, Doyle D, DeLarochellière R, Bergeron S, Lemieux J, Villeneuve J, Côté M, Bertrand OF, Poirier P, Clavel MA, Pibarot P, Dumont E.
    Am Heart J; 2009 Aug 30; 158(2):302-8. PubMed ID: 19619709
    [Abstract] [Full Text] [Related]

  • 6.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 7. Comparison of incidence and predictors of left bundle branch block after transcatheter aortic valve implantation using the CoreValve versus the Edwards valve.
    Franzoni I, Latib A, Maisano F, Costopoulos C, Testa L, Figini F, Giannini F, Basavarajaiah S, Mussardo M, Slavich M, Taramasso M, Cioni M, Longoni M, Ferrarello S, Radinovic A, Sala S, Ajello S, Sticchi A, Giglio M, Agricola E, Chieffo A, Montorfano M, Alfieri O, Colombo A.
    Am J Cardiol; 2013 Aug 15; 112(4):554-9. PubMed ID: 23726173
    [Abstract] [Full Text] [Related]

  • 8. Clinical implications of new-onset left bundle branch block after transcatheter aortic valve replacement: analysis of the PARTNER experience.
    Nazif TM, Williams MR, Hahn RT, Kapadia S, Babaliaros V, Rodés-Cabau J, Szeto WY, Jilaihawi H, Fearon WF, Dvir D, Dewey TM, Makkar RR, Xu K, Dizon JM, Smith CR, Leon MB, Kodali SK.
    Eur Heart J; 2014 Jun 21; 35(24):1599-607. PubMed ID: 24179072
    [Abstract] [Full Text] [Related]

  • 9. Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings.
    Bagur R, Rodés-Cabau J, Gurvitch R, Dumont É, Velianou JL, Manazzoni J, Toggweiler S, Cheung A, Ye J, Natarajan MK, Bainey KR, DeLarochellière R, Doyle D, Pibarot P, Voisine P, Côté M, Philippon F, Webb JG.
    JACC Cardiovasc Interv; 2012 May 21; 5(5):540-551. PubMed ID: 22625193
    [Abstract] [Full Text] [Related]

  • 10. Impact of a new conduction defect after transcatheter aortic valve implantation on left ventricular function.
    Hoffmann R, Herpertz R, Lotfipour S, Aktug Ö, Brehmer K, Lehmacher W, Autschbach R, Marx N, Lotfi S.
    JACC Cardiovasc Interv; 2012 Dec 21; 5(12):1257-63. PubMed ID: 23257374
    [Abstract] [Full Text] [Related]

  • 11. Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis.
    Nuis RJ, Van Mieghem NM, Schultz CJ, Tzikas A, Van der Boon RM, Maugenest AM, Cheng J, Piazza N, van Domburg RT, Serruys PW, de Jaegere PP.
    Eur Heart J; 2011 Aug 21; 32(16):2067-74. PubMed ID: 21622979
    [Abstract] [Full Text] [Related]

  • 12. Incidence and predictors of left bundle branch block after transcatheter aortic valve implantation.
    Aktug Ö, Dohmen G, Brehmer K, Koos R, Altiok E, Deserno V, Herpertz R, Autschbach R, Marx N, Hoffmann R.
    Int J Cardiol; 2012 Sep 20; 160(1):26-30. PubMed ID: 21458085
    [Abstract] [Full Text] [Related]

  • 13. Clinical impact of persistent left bundle-branch block after transcatheter aortic valve implantation with CoreValve Revalving System.
    Testa L, Latib A, De Marco F, De Carlo M, Agnifili M, Latini RA, Petronio AS, Ettori F, Poli A, De Servi S, Ramondo A, Napodano M, Klugmann S, Ussia GP, Tamburino C, Brambilla N, Colombo A, Bedogni F.
    Circulation; 2013 Mar 26; 127(12):1300-7. PubMed ID: 23443735
    [Abstract] [Full Text] [Related]

  • 14. Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve implantation.
    Fraccaro C, Buja G, Tarantini G, Gasparetto V, Leoni L, Razzolini R, Corrado D, Bonato R, Basso C, Thiene G, Gerosa G, Isabella G, Iliceto S, Napodano M.
    Am J Cardiol; 2011 Mar 01; 107(5):747-54. PubMed ID: 21247519
    [Abstract] [Full Text] [Related]

  • 15. Trends in the occurrence of new conduction abnormalities after transcatheter aortic valve implantation.
    van der Boon RM, Houthuizen P, Urena M, Poels TT, van Mieghem NM, Brueren GR, Altintas S, Nuis RJ, Serruys PW, van Garsse LA, van Domburg RT, Cabau JR, de Jaegere PP, Prinzen FW.
    Catheter Cardiovasc Interv; 2015 Apr 01; 85(5):E144-52. PubMed ID: 25504891
    [Abstract] [Full Text] [Related]

  • 16. Severe conduction defects requiring permanent pacemaker implantation in patients with a new-onset left bundle branch block after transcatheter aortic valve implantation.
    Nijenhuis VJ, Van Dijk VF, Chaldoupi SM, Balt JC, Ten Berg JM.
    Europace; 2017 Jun 01; 19(6):1015-1021. PubMed ID: 28340150
    [Abstract] [Full Text] [Related]

  • 17. Late Electrocardiographic Changes in Patients With New-Onset Left Bundle Branch Block Following Transcatheter Aortic Valve Implantation.
    Faroux L, Muntané-Carol G, Urena M, Nombela-Franco L, Amat-Santos I, Kleiman N, Munoz-Garcia A, Atienza F, Serra V, Deyell MW, Veiga-Fernandez G, Masson JB, Canadas-Godoy V, Himbert D, Fischer Q, Castrodeza J, Elizaga J, Pascual JF, Webb JG, de la Torre JM, Asmarats L, Pelletier-Beaumont E, Alméndarez M, Couture T, Philippon F, Rodes-Cabau J.
    Am J Cardiol; 2020 Mar 01; 125(5):795-802. PubMed ID: 31889524
    [Abstract] [Full Text] [Related]

  • 18. Patients without prolonged QRS after TAVI with CoreValve device do not experience high-degree atrio-ventricular block.
    Mouillet G, Lellouche N, Lim P, Meguro K, Yamamoto M, Deux JF, Monin JL, Bergoënd E, Dubois-Randé JL, Teiger E.
    Catheter Cardiovasc Interv; 2013 Apr 01; 81(5):882-7. PubMed ID: 22972678
    [Abstract] [Full Text] [Related]

  • 19. Long-term clinical outcome of persistent left bundle branch block after transfemoral aortic valve implantation.
    Keßler M, Gonska B, Seeger J, Rottbauer W, Wöhrle J.
    Catheter Cardiovasc Interv; 2019 Feb 15; 93(3):538-544. PubMed ID: 30298700
    [Abstract] [Full Text] [Related]

  • 20. Pacemaker dependency after transcatheter aortic valve implantation with the self-expanding Medtronic CoreValve System.
    van der Boon RM, Van Mieghem NM, Theuns DA, Nuis RJ, Nauta ST, Serruys PW, Jordaens L, van Domburg RT, de Jaegere PP.
    Int J Cardiol; 2013 Sep 30; 168(2):1269-73. PubMed ID: 23295037
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 49.