These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
377 related items for PubMed ID: 23164593
1. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS). Kosonen P, Vikman S, Jensen LO, Lassen JF, Harnek J, Olivecrona GK, Erglis A, Fossum E, Niemelä M, Kervinen K, Ylitalo A, Pietilä M, Aaroe J, Kellerth T, Saunamäki K, Thayssen P, Hellsten L, Thuesen L, Niemelä K. Int J Cardiol; 2013 Sep 30; 168(2):1010-6. PubMed ID: 23164593 [Abstract] [Full Text] [Related]
2. Intravascular ultrasound assessment of minimum lumen area and intimal hyperplasia in in-stent restenosis after drug-eluting or bare-metal stent implantation. The Nordic Intravascular Ultrasound Study (NIVUS). Jensen LO, Vikman S, Antonsen L, Kosonen P, Niemelä M, Christiansen EH, Kervinen K, Erglis A, Harnek J, Kumsars I, Thuesen L, Niemelä K. Cardiovasc Revasc Med; 2017 Dec 30; 18(8):577-582. PubMed ID: 29066343 [Abstract] [Full Text] [Related]
4. Late and very late coronary stent thrombosis: Intravascular ultrasound findings and associations with antiplatelet therapy. Pesarini G, Dandale R, Rigamonti A, Pighi M, Zivelonghi C, Mugnolo A, Ferrero V, Vassanelli C, Ribichini F. Catheter Cardiovasc Interv; 2013 Dec 01; 82(7):1056-65. PubMed ID: 23592553 [Abstract] [Full Text] [Related]
5. IVUS Findings in Late and Very Late Stent Thrombosis. A Comparison Between Bare-metal and Drug-eluting Stents. Fuentes L, Gómez-Lara J, Salvatella N, Gonzalo N, Hernández-Hernández F, Fernández-Nofrerias E, Sánchez-Recalde Á, Alfonso F, Romaguera R, Ferreiro JL, Roura G, Teruel L, Gracida M, Marcano AL, Gómez-Hospital JA, Cequier Á. Rev Esp Cardiol (Engl Ed); 2018 May 01; 71(5):335-343. PubMed ID: 28870640 [Abstract] [Full Text] [Related]
6. Risk of late-acquired incomplete stent apposition after drug-eluting stent versus bare-metal stent. A meta-analysis from 12 randomized trials. Sanchez-Recalde A, Moreno R, Barreales L, Rivero F, Galeote G, Jimenez-Valero S, Calvo L, López de Sá E, López-Sendón JL. J Invasive Cardiol; 2008 Aug 01; 20(8):417-22. PubMed ID: 18688067 [Abstract] [Full Text] [Related]
11. Mechanisms and Patterns of Intravascular Ultrasound In-Stent Restenosis Among Bare Metal Stents and First- and Second-Generation Drug-Eluting Stents. Goto K, Zhao Z, Matsumura M, Dohi T, Kobayashi N, Kirtane AJ, Rabbani LE, Collins MB, Parikh MA, Kodali SK, Leon MB, Moses JW, Mintz GS, Maehara A. Am J Cardiol; 2015 Nov 01; 116(9):1351-7. PubMed ID: 26341188 [Abstract] [Full Text] [Related]
13. A more than 2-year follow-up of incomplete apposition after drug-eluting stent implantation. Qian JY, Zhang F, Fan B, Ge L, Wang QB, Ge JB. Chin Med J (Engl); 2008 Mar 20; 121(6):498-502. PubMed ID: 18364132 [Abstract] [Full Text] [Related]
14. Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events: intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials. Hoffmann R, Morice MC, Moses JW, Fitzgerald PJ, Mauri L, Breithardt G, Schofer J, Serruys PW, Stoll HP, Leon MB. Heart; 2008 Mar 20; 94(3):322-8. PubMed ID: 17761505 [Abstract] [Full Text] [Related]
15. Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials. Doi H, Maehara A, Mintz GS, Yu A, Wang H, Mandinov L, Popma JJ, Ellis SG, Grube E, Dawkins KD, Weissman NJ, Turco MA, Ormiston JA, Stone GW. JACC Cardiovasc Interv; 2009 Dec 20; 2(12):1269-75. PubMed ID: 20129555 [Abstract] [Full Text] [Related]
16. Stent malapposition after sirolimus-eluting and bare-metal stent implantation in patients with ST-segment elevation myocardial infarction: acute and 9-month intravascular ultrasound results of the MISSION! intervention study. van der Hoeven BL, Liem SS, Dijkstra J, Bergheanu SC, Putter H, Antoni ML, Atsma DE, Bootsma M, Zeppenfeld K, Jukema JW, Schalij MJ. JACC Cardiovasc Interv; 2008 Apr 20; 1(2):192-201. PubMed ID: 19463300 [Abstract] [Full Text] [Related]
17. Outcomes with various drug-eluting or bare metal stents in patients with ST-segment-elevation myocardial infarction: a mixed treatment comparison analysis of trial level data from 34 068 patient-years of follow-up from randomized trials. Bangalore S, Amoroso N, Fusaro M, Kumar S, Feit F. Circ Cardiovasc Interv; 2013 Aug 20; 6(4):378-90. PubMed ID: 23922145 [Abstract] [Full Text] [Related]
18. Long-term outcomes following coronary drug-eluting- and bare-metal-stent implantation. Auer J, Leitner A, Berent R, Lamm G, Lassnig E, Krennmair G. Atherosclerosis; 2010 Jun 20; 210(2):503-9. PubMed ID: 20060973 [Abstract] [Full Text] [Related]
19. Comparison of newer-generation drug-eluting with bare-metal stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFORTABLE-AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) trials. Sabaté M, Räber L, Heg D, Brugaletta S, Kelbaek H, Cequier A, Ostojic M, Iñiguez A, Tüller D, Serra A, Baumbach A, von Birgelen C, Hernandez-Antolin R, Roffi M, Mainar V, Valgimigli M, Serruys PW, Jüni P, Windecker S. JACC Cardiovasc Interv; 2014 Jan 20; 7(1):55-63. PubMed ID: 24332419 [Abstract] [Full Text] [Related]
20. Late adverse events after implantation of sirolimus-eluting stent and bare-metal stent: long-term (5-7 years) follow-up of the Coronary Revascularization Demonstrating Outcome study-Kyoto registry Cohort-2. Natsuaki M, Morimoto T, Furukawa Y, Nakagawa Y, Kadota K, Yamaji K, Ando K, Shizuta S, Shiomi H, Tada T, Tazaki J, Kato Y, Hayano M, Abe M, Tamura T, Shirotani M, Miki S, Matsuda M, Takahashi M, Ishii K, Tanaka M, Aoyama T, Doi O, Hattori R, Kato M, Suwa S, Takizawa A, Takatsu Y, Shinoda E, Eizawa H, Takeda T, Lee JD, Inoko M, Ogawa H, Hamasaki S, Horie M, Nohara R, Kambara H, Fujiwara H, Mitsudo K, Nobuyoshi M, Kita T, Kimura T, CREDO-Kyoto PCI/CABG registry cohort-2 investigators. Circ Cardiovasc Interv; 2014 Apr 20; 7(2):168-79. PubMed ID: 24550439 [Abstract] [Full Text] [Related] Page: [Next] [New Search]