2. Stress distribution in the mini-screw and alveolar bone during orthodontic treatment: a finite element study analysis. Kuroda S, Nishii Y, Okano S, Sueishi K. J Orthod; 2014 Dec; 41(4):275-84. PubMed ID: 24812100 [Abstract] [Full Text] [Related]
4. Finite element analysis of miniscrew implants used for orthodontic anchorage. Liu TC, Chang CH, Wong TY, Liu JK. Am J Orthod Dentofacial Orthop; 2012 Apr; 141(4):468-76. PubMed ID: 22464529 [Abstract] [Full Text] [Related]
5. Three-dimensional modeling and finite element analysis in treatment planning for orthodontic tooth movement. Ammar HH, Ngan P, Crout RJ, Mucino VH, Mukdadi OM. Am J Orthod Dentofacial Orthop; 2011 Jan; 139(1):e59-71. PubMed ID: 21195258 [Abstract] [Full Text] [Related]
6. Bone stress when miniplates are used for orthodontic anchorage: finite element analysis. Huang YW, Chang CH, Wong TY, Liu JK. Am J Orthod Dentofacial Orthop; 2012 Oct; 142(4):466-72. PubMed ID: 22999669 [Abstract] [Full Text] [Related]
13. Optimized orthodontic palatal miniscrew implant insertion angulation: a finite element analysis. Poorsattar Bejeh Mir A, Ravadgar M, Poorsattar Bejeh Mir M. Int J Oral Maxillofac Implants; 2015 Oct; 30(1):e1-9. PubMed ID: 25265124 [Abstract] [Full Text] [Related]
14. Influence of tapered and external hexagon connections on bone stresses around tilted dental implants: three-dimensional finite element method with statistical analysis. de Faria Almeida DA, Pellizzer EP, Verri FR, Santiago JF, de Carvalho PS. J Periodontol; 2014 Feb; 85(2):261-9. PubMed ID: 23688104 [Abstract] [Full Text] [Related]
17. Evaluation of Platform Switching on Crestal Bone Stress in Tapered and Cylindrical Implants: A Finite Element Analysis. Rasouli-Ghahroudi AA, Geramy A, Yaghobee S, Khorsand A, Yousefifakhr H, Rokn A, Soolari A. J Int Acad Periodontol; 2015 Jan; 17(1):2-13. PubMed ID: 26233968 [Abstract] [Full Text] [Related]
18. Effects of thread depth, taper shape, and taper length on the mechanical properties of mini-implants. Chang JZ, Chen YJ, Tung YY, Chiang YY, Lai EH, Chen WP, Lin CP. Am J Orthod Dentofacial Orthop; 2012 Mar; 141(3):279-288. PubMed ID: 22381488 [Abstract] [Full Text] [Related]
19. Finite Element Analysis of Bone Stress for Miniscrew Implant Proximal to Root Under Occlusal Force and Implant Loading. Shan LH, Guo N, Zhou GJ, Qie H, Li CX, Lu L. J Craniofac Surg; 2015 Oct; 26(7):2072-6. PubMed ID: 26207429 [Abstract] [Full Text] [Related]
20. Finite element analysis of stress-breaking attachments on maxillary implant-retained overdentures. Tanino F, Hayakawa I, Hirano S, Minakuchi S. Int J Prosthodont; 2007 Oct; 20(2):193-8. PubMed ID: 17455444 [Abstract] [Full Text] [Related] Page: [Next] [New Search]