3. Operating theatre ventilation systems and microbial air contamination in total joint replacement surgery: results of the GISIO-ISChIA study. Agodi A, Auxilia F, Barchitta M, Cristina ML, D'Alessandro D, Mura I, Nobile M, Pasquarella C, Italian Study Group of Hospital Hygiene. J Hosp Infect; 2015 Jul; 90(3):213-9. PubMed ID: 25997801 [Abstract] [Full Text] [Related]
4. Heating, ventilation and air conditioning (HVAC) system, microbial air contamination and surgical site infection in hip and knee arthroplasties: the GISIO-SItI Ischia study. Pasquarella C, Barchitta M, D'Alessandro D, Cristina ML, Mura I, Nobile M, Auxilia F, Agodi A, Collaborators. Ann Ig; 2018 Jul; 30(5 Supple 2):22-35. PubMed ID: 30374509 [Abstract] [Full Text] [Related]
6. Laminar airflow decreases microbial air contamination compared with turbulent ventilated operating theatres during live total joint arthroplasty: a nationwide survey. Knudsen RJ, Knudsen SMN, Nymark T, Anstensrud T, Jensen ET, La Mia Malekzadeh MJ, Overgaard S. J Hosp Infect; 2021 Jul; 113():65-70. PubMed ID: 33932555 [Abstract] [Full Text] [Related]
7. Evaluation of Air Contamination in Orthopaedic Operating Theatres in Hospitals in Southern Italy: The IMPACT Project. Montagna MT, Rutigliano S, Trerotoli P, Napoli C, Apollonio F, D'Amico A, De Giglio O, Diella G, Lopuzzo M, Marzella A, Mascipinto S, Pousis C, Albertini R, Pasquarella C, D'Alessandro D, Serio G, Caggiano G. Int J Environ Res Public Health; 2019 Sep 25; 16(19):. PubMed ID: 31557819 [Abstract] [Full Text] [Related]
8. Electronic particle counting for evaluating the quality of air in operating theatres: a potential basis for standards? Seal DV, Clark RP. J Appl Bacteriol; 1990 Mar 25; 68(3):225-30. PubMed ID: 2341326 [Abstract] [Full Text] [Related]
9. [Air quality and microbiologic contamination in operating theatres]. Andersen BM, Røed RT, Solheim N, Levy F, Bratteberg A, Kristoffersen K, Moløkken I. Tidsskr Nor Laegeforen; 1998 Aug 30; 118(20):3148-51. PubMed ID: 9760859 [Abstract] [Full Text] [Related]
10. Real-time measurements of airborne biologic particles using fluorescent particle counter to evaluate microbial contamination: results of a comparative study in an operating theater. Dai C, Zhang Y, Ma X, Yin M, Zheng H, Gu X, Xie S, Jia H, Zhang L, Zhang W. Am J Infect Control; 2015 Jan 30; 43(1):78-81. PubMed ID: 25564128 [Abstract] [Full Text] [Related]
11. Microbial air monitoring in operating theatres: experience at the University Hospital of Parma. Pasquarella C, Vitali P, Saccani E, Manotti P, Boccuni C, Ugolotti M, Signorelli C, Mariotti F, Sansebastiano GE, Albertini R. J Hosp Infect; 2012 May 30; 81(1):50-7. PubMed ID: 22463976 [Abstract] [Full Text] [Related]
12. The Influence of Surgical Staff Behavior on Air Quality in a Conventionally Ventilated Operating Theatre during a Simulated Arthroplasty: A Case Study at the University Hospital of Parma. Pasquarella C, Balocco C, Colucci ME, Saccani E, Paroni S, Albertini L, Vitali P, Albertini R. Int J Environ Res Public Health; 2020 Jan 10; 17(2):. PubMed ID: 31936699 [Abstract] [Full Text] [Related]
13. Environmental controls in operating theatres. Dharan S, Pittet D. J Hosp Infect; 2002 Jun 10; 51(2):79-84. PubMed ID: 12090793 [Abstract] [Full Text] [Related]
14. Air sampling methods to evaluate microbial contamination in operating theatres: results of a comparative study in an orthopaedics department. Napoli C, Tafuri S, Montenegro L, Cassano M, Notarnicola A, Lattarulo S, Montagna MT, Moretti B. J Hosp Infect; 2012 Feb 10; 80(2):128-32. PubMed ID: 22138124 [Abstract] [Full Text] [Related]
15. [Biological risk in the operating room: microbiological monitoring of the environment and analysis of the associated variables]. Liguori G, Spagnoli G, Agozzino E, Marinelli A, Signoriello G, Lucariello A, Albano L, Di Onofrio V, Cammarota B, Capozza G, Lombardi R, Marinelli P. Ann Ig; 2005 Feb 10; 17(5):385-400. PubMed ID: 16353676 [Abstract] [Full Text] [Related]
16. Nine years of microbiological air monitoring in the operating theatres of a university hospital in Southern Italy. Squeri R, Genovese C, Trimarchi G, Antonuccio GM, Alessi V, Squeri A, La Fauci V. Ann Ig; 2019 Feb 10; 31(2 Supple 1):1-12. PubMed ID: 30994159 [Abstract] [Full Text] [Related]
17. [Microbial air monitoring in operating theatre: active and passive samplings]. Pasquarella C, Masia MD, Nnanga N, Sansebastiano GE, Savino A, Signorelli C, Veronesi L. Ann Ig; 2004 Feb 10; 16(1-2):375-86. PubMed ID: 15554542 [Abstract] [Full Text] [Related]
18. Risk factors for particulate and microbial contamination of air in operating theatres. Scaltriti S, Cencetti S, Rovesti S, Marchesi I, Bargellini A, Borella P. J Hosp Infect; 2007 Aug 10; 66(4):320-6. PubMed ID: 17655973 [Abstract] [Full Text] [Related]
19. Auditing the microbiological quality of the air in operating theatres. Whyte W, Thomas AM. Bone Joint J; 2024 Sep 01; 106-B(9):887-891. PubMed ID: 39216846 [Abstract] [Full Text] [Related]
20. Predicting bacterial populations based on airborne particulates: a study performed in nonlaminar flow operating rooms during joint arthroplasty surgery. Stocks GW, Self SD, Thompson B, Adame XA, O'Connor DP. Am J Infect Control; 2010 Apr 01; 38(3):199-204. PubMed ID: 19913327 [Abstract] [Full Text] [Related] Page: [Next] [New Search]