These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial. Ali ZA, Maehara A, Généreux P, Shlofmitz RA, Fabbiocchi F, Nazif TM, Guagliumi G, Meraj PM, Alfonso F, Samady H, Akasaka T, Carlson EB, Leesar MA, Matsumura M, Ozan MO, Mintz GS, Ben-Yehuda O, Stone GW, ILUMIEN III: OPTIMIZE PCI Investigators. Lancet; 2016 Nov 26; 388(10060):2618-2628. PubMed ID: 27806900 [Abstract] [Full Text] [Related]
24. Quantitative multi-modality imaging analysis of a fully bioresorbable stent: a head-to-head comparison between QCA, IVUS and OCT. Gutiérrez-Chico JL, Serruys PW, Girasis C, Garg S, Onuma Y, Brugaletta S, García-García H, van Es GA, Regar E. Int J Cardiovasc Imaging; 2012 Mar 26; 28(3):467-78. PubMed ID: 21359517 [Abstract] [Full Text] [Related]
25. Combined use of optical coherence tomography and intravascular ultrasound imaging in patients undergoing coronary interventions for stent thrombosis. Alfonso F, Dutary J, Paulo M, Gonzalo N, Pérez-Vizcayno MJ, Jiménez-Quevedo P, Escaned J, Bañuelos C, Hernández R, Macaya C. Heart; 2012 Aug 26; 98(16):1213-20. PubMed ID: 22826559 [Abstract] [Full Text] [Related]
27. Comparison Between Optical Frequency Domain Imaging and Intravascular Ultrasound for Percutaneous Coronary Intervention Guidance in Biolimus A9-Eluting Stent Implantation: A Randomized MISTIC-1 Non-Inferiority Trial. Muramatsu T, Ozaki Y, Nanasato M, Ishikawa M, Nagasaka R, Ohota M, Hashimoto Y, Yoshiki Y, Takatsu H, Ito K, Kamiya H, Yoshida Y, Murohara T, Izawa H, MISTIC-1 Investigators. Circ Cardiovasc Interv; 2020 Nov 26; 13(11):e009314. PubMed ID: 33106049 [Abstract] [Full Text] [Related]
28. Multi-modality imaging for stent edge assessment. Ann SH, Lim KH, De Jin C, Shin ES. Heart Vessels; 2015 Mar 26; 30(2):162-8. PubMed ID: 24481539 [Abstract] [Full Text] [Related]
29. First-in-man evaluation of intravascular optical frequency domain imaging (OFDI) of Terumo: a comparison with intravascular ultrasound and quantitative coronary angiography. Okamura T, Onuma Y, Garcia-Garcia HM, van Geuns RJ, Wykrzykowska JJ, Schultz C, van der Giessen WJ, Ligthart J, Regar E, Serruys PW. EuroIntervention; 2011 Apr 26; 6(9):1037-45. PubMed ID: 21518674 [Abstract] [Full Text] [Related]
30. Serial assessment of vessel interactions after drug-eluting stent implantation in unprotected distal left main coronary artery disease using frequency-domain optical coherence tomography. Fujino Y, Attizzani GF, Bezerra HG, Wang W, Tahara S, Yamamoto H, Chamie D, Kanaya T, Mehanna E, Takagi K, Nakamura S, Costa MA. JACC Cardiovasc Interv; 2013 Oct 26; 6(10):1035-45. PubMed ID: 24156964 [Abstract] [Full Text] [Related]
32. In vivo comparison of arterial lumen dimensions assessed by co-registered three-dimensional (3D) quantitative coronary angiography, intravascular ultrasound and optical coherence tomography. Tu S, Xu L, Ligthart J, Xu B, Witberg K, Sun Z, Koning G, Reiber JH, Regar E. Int J Cardiovasc Imaging; 2012 Aug 26; 28(6):1315-27. PubMed ID: 22261998 [Abstract] [Full Text] [Related]
33. A comparison of tissue prolapse with optical coherence tomography and intravascular ultrasound after drug-eluting stent implantation. Sohn J, Hur SH, Kim IC, Cho YK, Park HS, Yoon HJ, Nam CW, Kim YN, Kim KB. Int J Cardiovasc Imaging; 2015 Jan 26; 31(1):21-9. PubMed ID: 25273918 [Abstract] [Full Text] [Related]
34. Intra-stent tissue evaluation within bare metal and drug-eluting stents > 3 years since implantation in patients with mild to moderate neointimal proliferation using optical coherence tomography and virtual histology intravascular ultrasound. Kitabata H, Loh JP, Pendyala LK, Omar A, Ota H, Minha S, Magalhaes MA, Torguson R, Chen F, Satler LF, Pichard AD, Waksman R. Cardiovasc Revasc Med; 2014 Apr 26; 15(3):149-55. PubMed ID: 24767313 [Abstract] [Full Text] [Related]
35. A Practical Approach to Assessing Stent Results with IVUS or OCT. Hachinohe D, Mitomo S, Candilio L, Latib A. Methodist Debakey Cardiovasc J; 2018 Apr 26; 14(1):32-41. PubMed ID: 29623170 [Abstract] [Full Text] [Related]
36. Quantitative ex vivo and in vivo comparison of lumen dimensions measured by optical coherence tomography and intravascular ultrasound in human coronary arteries. Gonzalo N, Serruys PW, García-García HM, van Soest G, Okamura T, Ligthart J, Knaapen M, Verheye S, Bruining N, Regar E. Rev Esp Cardiol; 2009 Jun 26; 62(6):615-24. PubMed ID: 19480757 [Abstract] [Full Text] [Related]
37. Usefulness of Frequency Domain Optical Coherence Tomography Compared with Intravascular Ultrasound as a Guidance for Percutaneous Coronary Intervention. Kim IC, Yoon HJ, Shin ES, Kim MS, Park J, Cho YK, Park HS, Kim H, Nam CW, Han SW, Kim YN, Kim KB, Hur SH. J Interv Cardiol; 2016 Apr 26; 29(2):216-24. PubMed ID: 26927366 [Abstract] [Full Text] [Related]
38. Optical coherence tomography assessment of incidence, morphological characteristics, and spontaneous healing course of edge dissections following percutaneous coronary intervention with stent implantation in patients with non-ST segment elevation myocardial infarction. Antonsen L, Thayssen P, Hansen HS, Junker A, Veien KT, Hansen KN, Hougaard M, Jensen LO. Int J Cardiol; 2016 Nov 15; 223():466-474. PubMed ID: 27544607 [Abstract] [Full Text] [Related]
39. Fusion of 3D QCA and IVUS/OCT. Tu S, Holm NR, Koning G, Huang Z, Reiber JH. Int J Cardiovasc Imaging; 2011 Feb 15; 27(2):197-207. PubMed ID: 21264684 [Abstract] [Full Text] [Related]
40. Optical coherence tomography versus intravascular ultrasound to evaluate stent implantation in patients with calcific coronary artery disease. Gudmundsdottir I, Adamson P, Gray C, Spratt JC, Behan MW, Henriksen P, Newby DE, Mills N, Uren NG, Cruden NL. Open Heart; 2015 Feb 15; 2(1):e000225. PubMed ID: 26719807 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]