These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
625 related items for PubMed ID: 23400984
1. A feasibility study using the VivaSight Single Lumen™ to intubate the trachea through the Fastrach laryngeal mask airway: a preliminary report of 50 cases. Gaitini LA, Yanovski B, Mustafa S, Hagberg CA, Mora PC, Vaida SJ. Anesth Analg; 2013 Mar; 116(3):604-8. PubMed ID: 23400984 [Abstract] [Full Text] [Related]
2. [Roles of Cookgas and Fastrach intubating laryngeal mask airway for anticipated difficult tracheal intubation]. Yang D, Deng XM, Tong SY, Tang GZ, Wei LX, Sui JH, Wang L. Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2013 Apr; 35(2):207-12. PubMed ID: 23643011 [Abstract] [Full Text] [Related]
3. [Comparison of Cookgas and Fastrach intubating laryngeal mask airway with fiberoptic bronchoscope in anticipated difficult airway management]. Yang D, Deng XM, Tong SY, Tang GZ, Zhang YM, Wei LX, Sui JH, Sun YL, Liu JH, Wang L, Liu XW. Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2013 Oct; 35(5):477-82. PubMed ID: 24183034 [Abstract] [Full Text] [Related]
4. I-gel Versus LMA-Fastrach Supraglottic Airway for Flexible Bronchoscope-Guided Tracheal Intubation Using a Parker (GlideRite) Endotracheal Tube: A Randomized Controlled Trial. Moore A, Gregoire-Bertrand F, Massicotte N, Gauthier A, Lallo A, Ruel M, Todorov A, Girard F. Anesth Analg; 2015 Aug; 121(2):430-6. PubMed ID: 26076387 [Abstract] [Full Text] [Related]
9. Comparison of the VBM laryngeal tube and laryngeal mask airway for ventilation during manual in-line neck stabilisation. Noor Zairul M, Khairul Faizi A. Singapore Med J; 2006 Oct; 47(10):892-6. PubMed ID: 16990966 [Abstract] [Full Text] [Related]
12. The LMA CTrach, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients. Liu EH, Goy RW, Chen FG. Br J Anaesth; 2006 Mar; 96(3):396-400. PubMed ID: 16415313 [Abstract] [Full Text] [Related]
13. Comparison of blind tracheal intubation through the intubating laryngeal mask airway (LMA Fastrach™) and the Air-Q™. Karim YM, Swanson DE. Anaesthesia; 2011 Mar; 66(3):185-90. PubMed ID: 21320087 [Abstract] [Full Text] [Related]
14. Tracheal intubation with a camera embedded in the tube tip (Vivasight(™) ). Huitink JM, Koopman EM, Bouwman RA, Craenen A, Verwoert M, Krage R, Visser IE, Erwteman M, van Groeningen D, Tijink R, Schauer A. Anaesthesia; 2013 Jan; 68(1):74-8. PubMed ID: 23121322 [Abstract] [Full Text] [Related]
15. Flexible optical intubation via the Ambu Aura-i vs blind intubation via the single-use LMA Fastrach: a prospective randomized clinical trial. Artime CA, Altamirano A, Normand KC, Ferrario L, Aijazi H, Cattano D, Hagberg CA. J Clin Anesth; 2016 Sep; 33():41-6. PubMed ID: 27555131 [Abstract] [Full Text] [Related]
16. A comparison of blind intubation with the intubating laryngeal mask FASTRACH™ and the intubating laryngeal mask Ambu Aura-i™ a prospective randomised clinical trial. Schiewe R, Stoeck M, Gruenewald M, Hoecker J, Bein B. BMC Anesthesiol; 2019 Mar 30; 19(1):44. PubMed ID: 30927922 [Abstract] [Full Text] [Related]
17. Intraocular pressure and haemodynamic responses to insertion of the i-gel, laryngeal mask airway or endotracheal tube. Ismail SA, Bisher NA, Kandil HW, Mowafi HA, Atawia HA. Eur J Anaesthesiol; 2011 Jun 30; 28(6):443-8. PubMed ID: 21455075 [Abstract] [Full Text] [Related]