190 related items for PubMed ID: 23519743

  • 1. Assessment of damping capacity as an index of root proximity in self-drilling orthodontic mini-implants.
    Motoyoshi M, Uchida Y, Matsuoka M, Inaba M, Iwai H, Karasawa Y, Shimizu N.
    Clin Oral Investig; 2014 Jan; 18(1):321-6. PubMed ID: 23519743
    [Abstract] [Full Text] [Related]

  • 2. Are assessments of damping capacity and placement torque useful in estimating root proximity of orthodontic anchor screws?
    Motoyoshi M, Uchida Y, Inaba M, Ejima K, Honda K, Shimizu N.
    Am J Orthod Dentofacial Orthop; 2016 Jul; 150(1):124-9. PubMed ID: 27364214
    [Abstract] [Full Text] [Related]

  • 3. Root proximity and inclination of orthodontic mini-implants after placement: cone-beam computed tomography evaluation.
    Shinohara A, Motoyoshi M, Uchida Y, Shimizu N.
    Am J Orthod Dentofacial Orthop; 2013 Jul; 144(1):50-6. PubMed ID: 23810045
    [Abstract] [Full Text] [Related]

  • 4. Comparative study of the primary stability of self-drilling and self-tapping orthodontic miniscrews.
    Son S, Motoyoshi M, Uchida Y, Shimizu N.
    Am J Orthod Dentofacial Orthop; 2014 Apr; 145(4):480-5. PubMed ID: 24703286
    [Abstract] [Full Text] [Related]

  • 5. Cone-beam computed tomography evaluation of mini-implants after placement: Is root proximity a major risk factor for failure?
    Kim SH, Kang SM, Choi YS, Kook YA, Chung KR, Huang JC.
    Am J Orthod Dentofacial Orthop; 2010 Sep; 138(3):264-76. PubMed ID: 20816295
    [Abstract] [Full Text] [Related]

  • 6. Evaluation of clinical parameters for the stability of 2 types of miniscrews.
    Watanabe K, Lee S, Lee D, Zheng F, Kyung HM, Kim DG, Deguchi T.
    Am J Orthod Dentofacial Orthop; 2022 Mar; 161(3):437-444. PubMed ID: 34799196
    [Abstract] [Full Text] [Related]

  • 7. Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: a systematic review.
    Meursinge Reynders R, Ladu L, Ronchi L, Di Girolamo N, de Lange J, Roberts N, Plüddemann A.
    Syst Rev; 2016 Mar 31; 5():50. PubMed ID: 27036120
    [Abstract] [Full Text] [Related]

  • 8. Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants.
    Motoyoshi M, Yoshida T, Ono A, Shimizu N.
    Int J Oral Maxillofac Implants; 2007 Mar 31; 22(5):779-84. PubMed ID: 17974113
    [Abstract] [Full Text] [Related]

  • 9. Accurate pre-surgical determination for self-drilling miniscrew implant placement using surgical guides and cone-beam computed tomography.
    Miyazawa K, Kawaguchi M, Tabuchi M, Goto S.
    Eur J Orthod; 2010 Dec 31; 32(6):735-40. PubMed ID: 20413451
    [Abstract] [Full Text] [Related]

  • 10. Safe placement techniques for self-drilling orthodontic mini-implants.
    Tachibana R, Motoyoshi M, Shinohara A, Shigeeda T, Shimizu N.
    Int J Oral Maxillofac Surg; 2012 Nov 31; 41(11):1439-44. PubMed ID: 22763139
    [Abstract] [Full Text] [Related]

  • 11. Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants.
    Çehreli S, Arman-Özçırpıcı A.
    Am J Orthod Dentofacial Orthop; 2012 Feb 31; 141(2):187-95. PubMed ID: 22284286
    [Abstract] [Full Text] [Related]

  • 12. Insertion Torques of Self-Drilling Mini-Implants in Simulated Mandibular Bone: Assessment of Potential for Implant Fracture.
    Hosein YK, Smith A, Dunning CE, Tassi A.
    Int J Oral Maxillofac Implants; 2016 Feb 31; 31(3):e57-64. PubMed ID: 27183083
    [Abstract] [Full Text] [Related]

  • 13. Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis-an animal study.
    Matys J, Flieger R, Tenore G, Grzech-Leśniak K, Romeo U, Dominiak M.
    Lasers Med Sci; 2018 Apr 31; 33(3):489-495. PubMed ID: 29127605
    [Abstract] [Full Text] [Related]

  • 14. Effects of tooth root contact on the stability of orthodontic anchor screws in the maxilla: Comparison between self-drilling and self-tapping methods.
    Iwai H, Motoyoshi M, Uchida Y, Matsuoka M, Shimizu N.
    Am J Orthod Dentofacial Orthop; 2015 Apr 31; 147(4):483-91. PubMed ID: 25836008
    [Abstract] [Full Text] [Related]

  • 15. Root proximity and stability of orthodontic anchor screws.
    Shigeeda T.
    J Oral Sci; 2014 Mar 31; 56(1):59-65. PubMed ID: 24739709
    [Abstract] [Full Text] [Related]

  • 16. Comparative analysis of two navigation techniques based on augmented reality technology for the orthodontic mini-implants placement.
    Riad Deglow E, Zubizarreta-Macho Á, González Menéndez H, Lorrio Castro J, Galparsoro Catalán A, Tzironi G, Lobo Galindo AB, Alonso Ezpeleta LÓ, Hernández Montero S.
    BMC Oral Health; 2023 Aug 05; 23(1):542. PubMed ID: 37543581
    [Abstract] [Full Text] [Related]

  • 17. Evaluation of orthodontic mini-implant placement: a CBCT study.
    Kalra S, Tripathi T, Rai P, Kanase A.
    Prog Orthod; 2014 Nov 18; 15(1):61. PubMed ID: 25406652
    [Abstract] [Full Text] [Related]

  • 18. Fracture resistance of orthodontic mini-implants: a biomechanical in vitro study.
    Wilmes B, Panayotidis A, Drescher D.
    Eur J Orthod; 2011 Aug 18; 33(4):396-401. PubMed ID: 21310766
    [Abstract] [Full Text] [Related]

  • 19. Recommended placement torque when tightening an orthodontic mini-implant.
    Motoyoshi M, Hirabayashi M, Uemura M, Shimizu N.
    Clin Oral Implants Res; 2006 Feb 18; 17(1):109-14. PubMed ID: 16441792
    [Abstract] [Full Text] [Related]

  • 20. Comparison of primary stability of used and unused self-tapping and self-drilling orthodontic mini-implants.
    Baser B, Ozel MB.
    Adv Clin Exp Med; 2024 May 18; 33(5):483-489. PubMed ID: 37676101
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 10.