These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
144 related items for PubMed ID: 23535183
1. Gastroduodenal artery recanalization after transcatheter fibered coil embolization for prevention of hepaticoenteric flow: incidence and predisposing technical factors in 142 patients. Enriquez J, Javadi S, Murthy R, Ensor J, Mahvash A, Abdelsalam ME, Madoff DC, Wallace MJ, Avritscher R. Acta Radiol; 2013 Sep; 54(7):790-4. PubMed ID: 23535183 [Abstract] [Full Text] [Related]
2. Embolization of the gastroduodenal artery before selective internal radiotherapy: a prospectively randomized trial comparing platinum-fibered microcoils with the Amplatzer Vascular Plug II. Pech M, Kraetsch A, Wieners G, Redlich U, Gaffke G, Ricke J, Dudeck O. Cardiovasc Intervent Radiol; 2009 May; 32(3):455-61. PubMed ID: 19137369 [Abstract] [Full Text] [Related]
3. Superiority of proximal embolization of the gastroduodenal artery with the Amplatzer vascular plug 4 before yttrium-90 radioembolization: a retrospective comparison with coils in 134 patients. Bulla K, Hubich S, Pech M, Löwenthal D, Ricke J, Dudeck O. Cardiovasc Intervent Radiol; 2014 Apr; 37(2):396-404. PubMed ID: 23842683 [Abstract] [Full Text] [Related]
4. Yttrium-90 Radioembolization with Resin Microspheres without Routine Embolization of the Gastroduodenal Artery. Ward TJ, Louie JD, Sze DY. J Vasc Interv Radiol; 2017 Feb; 28(2):246-253. PubMed ID: 27884683 [Abstract] [Full Text] [Related]
5. Protective embolization of the gastroduodenal artery with a one-HydroCoil technique in radioembolization procedures. López-Benítez R, Hallscheidt P, Kratochwil C, Ernst C, Kara L, Rusch O, Vock P, Kettenbach J. Cardiovasc Intervent Radiol; 2013 Feb; 36(1):105-10. PubMed ID: 22414984 [Abstract] [Full Text] [Related]
6. Embolization of the gastroduodenal artery before selective internal radiotherapy: a prospectively randomized trial comparing standard pushable coils with fibered interlock detachable coils. Dudeck O, Bulla K, Wieners G, Ruehl R, Ulrich G, Amthauer H, Ricke J, Pech M. Cardiovasc Intervent Radiol; 2011 Feb; 34(1):74-80. PubMed ID: 20390272 [Abstract] [Full Text] [Related]
7. Prospective comparison of hydrogel-coated microcoils versus fibered platinum microcoils in the prophylactic embolization of the gastroduodenal artery before yttrium-90 radioembolization. Maleux G, Deroose C, Fieuws S, Van Cutsem E, Heye S, Bosmans H, Verslype C. J Vasc Interv Radiol; 2013 Jun; 24(6):797-803; quiz 804. PubMed ID: 23582440 [Abstract] [Full Text] [Related]
8. Radioembolization: Is Prophylactic Embolization of Hepaticoenteric Arteries Necessary? A Systematic Review. Borggreve AS, Landman AJEMC, Vissers CMJ, De Jong CD, Lam MGEH, Monninkhof EM, Prince JF. Cardiovasc Intervent Radiol; 2016 May; 39(5):696-704. PubMed ID: 26935724 [Abstract] [Full Text] [Related]
9. Embolisation of the gastroduodenal artery is not necessary in the presence of reversed flow before yttrium-90 radioembolisation. Daghir AA, Gungor H, Haydar AA, Wasan HS, Tait NP. Cardiovasc Intervent Radiol; 2012 Aug; 35(4):839-44. PubMed ID: 21691917 [Abstract] [Full Text] [Related]
10. Development of new hepaticoenteric collateral pathways after hepatic arterial skeletonization in preparation for yttrium-90 radioembolization. Abdelmaksoud MH, Hwang GL, Louie JD, Kothary N, Hofmann LV, Kuo WT, Hovsepian DM, Sze DY. J Vasc Interv Radiol; 2010 Sep; 21(9):1385-95. PubMed ID: 20688531 [Abstract] [Full Text] [Related]
11. Selective internal radiation therapy of hepatic tumours: is coiling of the gastroduodenal artery always beneficial? Schelhorn J, Theysohn J, Ertle J, Schlaak JF, Mueller S, Bockisch A, Lauenstein T. Clin Radiol; 2014 May; 69(5):e216-22. PubMed ID: 24581959 [Abstract] [Full Text] [Related]
12. Anatomic variants of arteries often coil-occluded prior to hepatic radioembolization. Powerski MJ, Erxleben C, Scheurig-Münkler C, Geisel D, Hamm B, Gebauer B. Acta Radiol; 2015 Feb; 56(2):159-65. PubMed ID: 24477267 [Abstract] [Full Text] [Related]
13. Assessing Intra-arterial Complications of Planning and Treatment Angiograms for Y-90 Radioembolization. Ahmed O, Patel MV, Masrani A, Chong B, Osman M, Tasse J, Soni J, Turba UC, Arslan B. Cardiovasc Intervent Radiol; 2017 May; 40(5):704-711. PubMed ID: 28078375 [Abstract] [Full Text] [Related]
14. Therapeutic embolization of the gastroduodenal artery in hepatic artery infusion chemotherapy. Kuribayashi S, Phillips DA, Harrington DP, Bettmann MA, Garnic JD, Come SE, Levin DC. AJR Am J Roentgenol; 1981 Dec; 137(6):1169-72. PubMed ID: 6459012 [Abstract] [Full Text] [Related]
15. Prospective randomized trial comparing pushable coil and detachable coil during percutaneous implantation of port-catheter system for hepatic artery infusion chemotherapy. Park SI, Lee SJ, Lee M, Lee MS, Kim GM, Kim MD, Won JY, Lee DY. Abdom Imaging; 2015 Mar; 40(3):595-600. PubMed ID: 25214068 [Abstract] [Full Text] [Related]
16. Hepatic artery infusion catheter implantation without embolization of the gastroduodenal artery in cases of retrograde blood flow. Wang YJ, Lao IH, Tzeng WS, Chang YK, Wu RH, Chang SC, Chen MC, Fang JL. J Vasc Interv Radiol; 2010 Aug; 21(8):1297-300. PubMed ID: 20598568 [Abstract] [Full Text] [Related]
17. Value of transcatheter arterial embolization with coils and n-butyl cyanoacrylate for long-term hepatic arterial infusion chemotherapy. Yamagami T, Kato T, Iida S, Tanaka O, Nishimura T. Radiology; 2004 Mar; 230(3):792-802. PubMed ID: 14739309 [Abstract] [Full Text] [Related]
19. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: implications for planning 90Y radioembolization? Burgmans MC, Too CW, Kao YH, Goh AS, Chow PK, Tan BS, Tay KH, Lo RH. Eur J Radiol; 2012 Dec; 81(12):3979-84. PubMed ID: 22954411 [Abstract] [Full Text] [Related]