These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Influence of a machined collar on crestal bone changes around titanium implants: a histometric study in the canine mandible. Hermann JS, Jones AA, Bakaeen LG, Buser D, Schoolfield JD, Cochran DL. J Periodontol; 2011 Sep; 82(9):1329-38. PubMed ID: 21486176 [Abstract] [Full Text] [Related]
8. Influence of Four Different Abutment Materials and the Adhesive Joint of Two-Piece Abutments on Cervical Implant Bone and Soft Tissue. Mehl C, Gassling V, Schultz-Langerhans S, Açil Y, Bähr T, Wiltfang J, Kern M. Int J Oral Maxillofac Implants; 2016 Sep; 31(6):1264-1272. PubMed ID: 27861650 [Abstract] [Full Text] [Related]
9. The mucosal attachment at different abutments. An experimental study in dogs. Abrahamsson I, Berglundh T, Glantz PO, Lindhe J. J Clin Periodontol; 1998 Sep; 25(9):721-7. PubMed ID: 9763327 [Abstract] [Full Text] [Related]
11. Early loading of nonsubmerged titanium implants with a chemically modified sand-blasted and acid-etched surface: 6-month results of a prospective case series study in the posterior mandible focusing on peri-implant crestal bone changes and implant stability quotient (ISQ) values. Bornstein MM, Hart CN, Halbritter SA, Morton D, Buser D. Clin Implant Dent Relat Res; 2009 Dec; 11(4):338-47. PubMed ID: 19438966 [Abstract] [Full Text] [Related]
15. Evaluation of a new titanium-zirconium dental implant: a biomechanical and histological comparative study in the mini pig. Gottlow J, Dard M, Kjellson F, Obrecht M, Sennerby L. Clin Implant Dent Relat Res; 2012 Aug; 14(4):538-45. PubMed ID: 20586785 [Abstract] [Full Text] [Related]
16. Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible. Hermann JS, Schoolfield JD, Schenk RK, Buser D, Cochran DL. J Periodontol; 2001 Oct; 72(10):1372-83. PubMed ID: 11699479 [Abstract] [Full Text] [Related]
17. Influence of Implant transmucosal design on early peri-implant tissue responses in beagle dogs. Huh JB, Rheu GB, Kim YS, Jeong CM, Lee JY, Shin SW. Clin Oral Implants Res; 2014 Aug; 25(8):962-8. PubMed ID: 23647221 [Abstract] [Full Text] [Related]
18. Histological and immunohistochemical analysis of initial and early subepithelial connective tissue attachment at chemically modified and conventional SLA titanium implants. A pilot study in dogs. Schwarz F, Herten M, Sager M, Wieland M, Dard M, Becker J. Clin Oral Investig; 2007 Sep; 11(3):245-55. PubMed ID: 17361452 [Abstract] [Full Text] [Related]
19. Loaded custom-made zirconia and titanium implants show similar osseointegration: an animal experiment. Kohal RJ, Weng D, Bächle M, Strub JR. J Periodontol; 2004 Sep; 75(9):1262-8. PubMed ID: 15515343 [Abstract] [Full Text] [Related]
20. Peri-implant soft tissue integration of immediately loaded implants in the posterior macaque mandible: a histomorphometric study. Siar CH, Toh CG, Romanos G, Swaminathan D, Ong AH, Yaacob H, Nentwig GH. J Periodontol; 2003 May; 74(5):571-8. PubMed ID: 12816287 [Abstract] [Full Text] [Related] Page: [Next] [New Search]