509 related items for PubMed ID: 23784878
1. System for verifiable CT radiation dose optimization based on image quality. part I. Optimization model. Larson DB, Wang LL, Podberesky DJ, Goske MJ. Radiology; 2013 Oct; 269(1):167-76. PubMed ID: 23784878 [Abstract] [Full Text] [Related]
2. System for verifiable CT radiation dose optimization based on image quality. part II. process control system. Larson DB, Malarik RJ, Hall SM, Podberesky DJ. Radiology; 2013 Oct; 269(1):177-85. PubMed ID: 23784877 [Abstract] [Full Text] [Related]
5. Introduction of an effective method for the optimization of CT protocols using iterative reconstruction algorithms: comparison with patient data. Kordolaimi SD, Saradeas I, Ploussi A, Pantos I, Argentos S, Efstathopoulos EP. AJR Am J Roentgenol; 2014 Oct; 203(4):W434-9. PubMed ID: 25247973 [Abstract] [Full Text] [Related]
9. Does a combination of dose modulation with fast gantry rotation time limit CT image quality? Israel GM, Herlihy S, Rubinowitz AN, Cornfeld D, Brink J. AJR Am J Roentgenol; 2008 Jul; 191(1):140-4. PubMed ID: 18562737 [Abstract] [Full Text] [Related]
11. Pediatric CT dose reduction for suspected appendicitis: a practice quality improvement project using artificial Gaussian noise--part 1, computer simulations. Callahan MJ, Kleinman PL, Strauss KJ, Bandos A, Taylor GA, Tsai A, Kleinman PK. AJR Am J Roentgenol; 2015 Jan; 204(1):W86-94. PubMed ID: 25539280 [Abstract] [Full Text] [Related]
12. Relating noise to image quality indicators in CT examinations with tube current modulation. Solomon JB, Li X, Samei E. AJR Am J Roentgenol; 2013 Mar; 200(3):592-600. PubMed ID: 23436849 [Abstract] [Full Text] [Related]
13. Characterization of a computed tomography iterative reconstruction algorithm by image quality evaluations with an anthropomorphic phantom. Rampado O, Bossi L, Garabello D, Davini O, Ropolo R. Eur J Radiol; 2012 Nov; 81(11):3172-7. PubMed ID: 22817847 [Abstract] [Full Text] [Related]
14. Relationships of clinical protocols and reconstruction kernels with image quality and radiation dose in a 128-slice CT scanner: study with an anthropomorphic and water phantom. Paul J, Krauss B, Banckwitz R, Maentele W, Bauer RW, Vogl TJ. Eur J Radiol; 2012 May; 81(5):e699-703. PubMed ID: 21316888 [Abstract] [Full Text] [Related]