These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Comparison between manual and automated analysis for the quantification of carotid wall by using sonography. A validation study with CT. Saba L, Montisci R, Molinari F, Tallapally N, Zeng G, Mallarini G, Suri JS. Eur J Radiol; 2012 May; 81(5):911-8. PubMed ID: 21429684 [Abstract] [Full Text] [Related]
5. CARES 3.0: a two stage system combining feature-based recognition and edge-based segmentation for CIMT measurement on a multi-institutional ultrasound database of 300 images. Molinari F, Meiburger KM, Acharya UR, Zeng G, Rodrigues PS, Saba L, Nicolaides A, Suri JS. Annu Int Conf IEEE Eng Med Biol Soc; 2011 May; 2011():5149-52. PubMed ID: 22255498 [Abstract] [Full Text] [Related]
6. Validation of the Carotid Intima-Media Thickness Variability: Can Manual Segmentations Be Trusted as Ground Truth? Meiburger KM, Molinari F, Wong J, Aguilar L, Gallo D, Steinman DA, Morbiducci U. Ultrasound Med Biol; 2016 Jul; 42(7):1598-611. PubMed ID: 27072077 [Abstract] [Full Text] [Related]
9. Completely automated robust edge snapper for carotid ultrasound IMT measurement on a multi-institutional database of 300 images. Molinari F, Rajendra Acharya U, Zeng G, Meiburger KM, Suri JS. Med Biol Eng Comput; 2011 Aug; 49(8):935-45. PubMed ID: 21509593 [Abstract] [Full Text] [Related]
11. Carotid artery recognition system: a comparison of three automated paradigms for ultrasound images. Molinari F, Meiburger KM, Zeng G, Acharya UR, Liboni W, Nicolaides A, Suri JS. Med Phys; 2012 Jan; 39(1):378-91. PubMed ID: 22225307 [Abstract] [Full Text] [Related]
13. Three-dimensional ultrasound of carotid atherosclerosis: semiautomated segmentation using a level set-based method. Ukwatta E, Awad J, Ward AD, Buchanan D, Samarabandu J, Parraga G, Fenster A. Med Phys; 2011 May; 38(5):2479-93. PubMed ID: 21776783 [Abstract] [Full Text] [Related]
14. An automated, interactive analysis system for ultrasound sequences of the common carotid artery. Teynor A, Caviezel S, Dratva J, Künzli N, Schmidt-Trucksäss A. Ultrasound Med Biol; 2012 Aug; 38(8):1440-50. PubMed ID: 22749339 [Abstract] [Full Text] [Related]
15. Constrained snake vs. conventional snake for carotid ultrasound automated IMT measurements on multi-center data sets. Molinari F, Meiburger KM, Saba L, Acharya UR, Ledda M, Nicolaides A, Suri JS. Ultrasonics; 2012 Sep; 52(7):949-61. PubMed ID: 22482369 [Abstract] [Full Text] [Related]
16. Carotid automated ultrasound double line extraction system (CADLES) via Edge-Flow. Meiburger KM, Molinari F, Zeng G, Saba L, Suri JS. Annu Int Conf IEEE Eng Med Biol Soc; 2011 Sep; 2011():575-8. PubMed ID: 22254375 [Abstract] [Full Text] [Related]