These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
308 related items for PubMed ID: 23897051
1. Prospective, Self-controlled, Comparative Study of Transposterior Arch Lateral Mass Screw Fixation and Lateral Mass Screw Fixation of the Atlas in the Treatment of Atlantoaxial Instability. He B, Yan L, Xu Z, Chang Z, Liu T, Hao D. J Spinal Disord Tech; 2015 Aug; 28(7):E427-32. PubMed ID: 23897051 [Abstract] [Full Text] [Related]
2. A prospective, double-blind, randomized controlled trial of treatment of atlantoaxial instability with C1 posterior arches >4 mm by comparing C1 pedicle with lateral mass screws fixation. Yan L, He B, Liu T, Yang L, Hao D. BMC Musculoskelet Disord; 2016 Apr 14; 17():164. PubMed ID: 27075577 [Abstract] [Full Text] [Related]
3. Clinical application of the "pedicle exposure technique" for atlantoaxial instability patients with a narrow c1 posterior arch. Tan M, Dong L, Wang W, Tang X, Yi P, Yang F, Hao Q, Zhang G. J Spinal Disord Tech; 2015 Feb 14; 28(1):25-30. PubMed ID: 24686332 [Abstract] [Full Text] [Related]
4. Clinical and radiological comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation. Lee SH, Kim ES, Sung JK, Park YM, Eoh W. J Clin Neurosci; 2010 Jul 14; 17(7):886-92. PubMed ID: 20399666 [Abstract] [Full Text] [Related]
5. C1 Titanium Cables Combined with C2 Pedicle Screw-Rod Fixation for Atlantoaxial Instability Not Suitable for Placement of C1 Screws. Zhang JH, Zhang ZJ, Zhu Y, Shi JD, Li B, Lu YS. World Neurosurg; 2018 Dec 14; 120():e453-e456. PubMed ID: 30149165 [Abstract] [Full Text] [Related]
6. One-step reduction and fixation applying transposterior arch lateral mass screw of C1 combined with pedicle screw of C2 and rod system for pediatric acute atlantoaxial rotatory subluxation with injury of transverse ligament. Guo X, Xie N, Lu X, Guo Q, Deng Y, Ni B. Spine (Phila Pa 1976); 2015 Mar 01; 40(5):E272-8. PubMed ID: 25901982 [Abstract] [Full Text] [Related]
7. Transposterior Arch Lateral Mass Screw for C1 Fixation: Application of a 3.5-mm-Diameter Screw in the Vertebral Artery Groove with a Height of ≤3.5 mm. Li C, Sun N, Li L, Duan J, Zhang Y. World Neurosurg; 2019 Jul 01; 127():e480-e487. PubMed ID: 30922900 [Abstract] [Full Text] [Related]
8. C2 pedicle screw and plate combined with C1 titanium cable fixation for the treatment of atlantoaxial instability not suitable for placement of C1 screw. Xiao ZM, Zhan XL, Gong DF, Chen QF, Luo GB, Jiang H. J Spinal Disord Tech; 2008 Oct 01; 21(7):514-7. PubMed ID: 18836364 [Abstract] [Full Text] [Related]
9. Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass. Tan M, Wang H, Wang Y, Zhang G, Yi P, Li Z, Wei H, Yang F. Spine (Phila Pa 1976); 2003 May 01; 28(9):888-95. PubMed ID: 12942004 [Abstract] [Full Text] [Related]
10. Comparison of Outcomes Between C1-C2 Screw-Hook Fixation and C1-C2 Screw-Rod Fixation for Treating Reducible Atlantoaxial Dislocation. Ni B, Zhao W, Guo Q, Zhang M, Chen J, Guo X, Lu X, Xie N. Spine (Phila Pa 1976); 2017 Oct 15; 42(20):1587-1593. PubMed ID: 28296813 [Abstract] [Full Text] [Related]
11. [Atlanto-axial pedicle screw fixation through posterior approach for treatment of atlanto-axial joint instability]. Zuo CG, Liu XJ, Wang XH, Wang JS. Zhongguo Gu Shang; 2013 Jan 15; 26(1):33-7. PubMed ID: 23617139 [Abstract] [Full Text] [Related]
12. C1 lateral mass fixation: a comparison of constructs. Mummaneni PV, Lu DC, Dhall SS, Mummaneni VP, Chou D. Neurosurgery; 2010 Mar 15; 66(3 Suppl):153-60. PubMed ID: 20173519 [Abstract] [Full Text] [Related]
13. C1 posterior arch crossing screw fixation for atlantoaxial joint instability. Jin GX, Wang H, Li L, Cui SQ, Duan JZ. Spine (Phila Pa 1976); 2013 Oct 15; 38(22):E1397-404. PubMed ID: 23873239 [Abstract] [Full Text] [Related]