These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
237 related items for PubMed ID: 23897107
41. Inversion of lithium heparin gel tubes after centrifugation is a significant source of bias in clinical chemistry testing. Lippi G, Salvagno GL, Danese E, Lima-Oliveira G, Brocco G, Guidi GC. Clin Chim Acta; 2014 Sep 25; 436():183-7. PubMed ID: 24915600 [Abstract] [Full Text] [Related]
42. Seasonal pseudohyperkalaemia: no longer an issue? Turner HE, Peake RW, Allison JJ. Ann Clin Biochem; 2012 Jan 25; 49(Pt 1):94-6. PubMed ID: 22067093 [Abstract] [Full Text] [Related]
43. Pneumatic tube system transport and false hyperkalemia related to leukocytosis: a retrospective analysis. Grzych G, Roland E, Lezier D, Beauvais D, Maboudou P, Lippi G. Ann Biol Clin (Paris); 2019 Jun 01; 77(3):281-286. PubMed ID: 31115339 [Abstract] [Full Text] [Related]
44. Using BD Vacutainer CD4 Stabilization Tubes for Absolute Cluster of Differentiation Type 4 Cell Count Measurement on BD FacsCount and Partec Cyflow Cytometers: A Method Comparison Study from Zimbabwe. Vogt F, Van den Bergh R, Bernasconi A, Moyo B, Havazvidi L, Bastard M, Flevaud L, Taziwa F, Makondo E, Mtapuri-Zinyowera S. PLoS One; 2015 Jun 01; 10(8):e0136537. PubMed ID: 26295802 [Abstract] [Full Text] [Related]
45. Investigation of outpatients referred to a chemical pathologist with potential pseudohyperkalaemia. Kapoor AK, Ravi A, Twomey PJ. J Clin Pathol; 2009 Oct 01; 62(10):920-3. PubMed ID: 19783721 [Abstract] [Full Text] [Related]
46. Pseudohyperkalaemia with acute leukaemia: association with pneumatic tube transport of blood specimens. Ku AS, Chen RH, Law RL. Hong Kong Med J; 2014 Apr 01; 20(2):158-60. PubMed ID: 24714171 [Abstract] [Full Text] [Related]
47. Blood withdrawn through a cannula valve connector does not result in clinically significant haemolysis. Paoloni R, Taghizadeh M, Kouzios D, Janu M. Emerg Med Australas; 2010 Aug 01; 22(4):310-5. PubMed ID: 20629698 [Abstract] [Full Text] [Related]
48. Leaky cell syndrome: a rare cause of pseudohyperkalaemia. Lukens MV, de Mare A, Kerbert-Dreteler MJ, van den Bergh FA. Ann Clin Biochem; 2012 Jan 01; 49(Pt 1):97-100. PubMed ID: 22042978 [Abstract] [Full Text] [Related]
49. A Multicenter Evaluation of a Nongel Mechanical Separator Plasma Blood Collection Tube for Testing of Selected Therapeutic Drugs. Morosyuk S, Berube J, Christenson R, Wu AHB, Uettwiller-Geiger D, Palicka V, Prusa R, Zima T, Shaw K, Plokhoy E, Ahuja AJ, Stankovic AK. J Appl Lab Med; 2020 Jul 01; 5(4):671-685. PubMed ID: 32603441 [Abstract] [Full Text] [Related]
50. Reducing blood sample hemolysis in the emergency department using S-Monovette® in aspiration mode. Omar E, Allen JC, Jamil AKBM, Iskandar MFKB, Norbu K, Tsang C, Yin J, Ganti S, Siew Kim O, Hock MOE. Pract Lab Med; 2023 May 01; 35():e00315. PubMed ID: 37325011 [Abstract] [Full Text] [Related]
51. Effects of collecting blood into plastic heparinised vacutainer tubes and storage conditions on blood gas analysis values in horses. Noël PG, Couëtil L, Constable PD. Equine Vet J Suppl; 2010 Nov 01; (38):91-7. PubMed ID: 21058988 [Abstract] [Full Text] [Related]
52. The use of S-Monovette is effective to reduce the burden of hemolysis in a large urban emergency department. Lippi G, Bonelli P, Bonfanti L, Cervellin G. Biochem Med (Zagreb); 2015 Nov 01; 25(1):69-72. PubMed ID: 25672469 [Abstract] [Full Text] [Related]
53. Seasonal factitious increase in serum potassium: still a problem and should be recognised. Davis KR, Crook MA. Clin Biochem; 2014 Dec 01; 47(18):283-6. PubMed ID: 25192691 [Abstract] [Full Text] [Related]
54. The quality of diagnostic testing may be impaired during shipment of lithium-heparin gel tubes. Da Rin G, Lippi G. Clin Chem Lab Med; 2014 Nov 01; 52(11):1633-7. PubMed ID: 24960155 [Abstract] [Full Text] [Related]
55. Pneumatic transport is critical for leukaemic patients with major leukocytosis: what precautions to measure lactate dehydrogenase, potassium and aspartate aminotransferase? Guiheneuf R, Vuillaume I, Mangalaboyi J, Launay D, Berthon C, Maury JC, Maboudou P, Rousseaux J. Ann Clin Biochem; 2010 Jan 01; 47(Pt 1):94-6. PubMed ID: 19940199 [Abstract] [Full Text] [Related]
56. Effect of blood collection tubes on total triiodothyronine and other laboratory assays. Bowen RA, Chan Y, Cohen J, Rehak NN, Hortin GL, Csako G, Remaley AT. Clin Chem; 2005 Feb 01; 51(2):424-33. PubMed ID: 15576427 [Abstract] [Full Text] [Related]
57. Seasonal pseudohyperkalaemia. Sinclair D, Briston P, Young R, Pepin N. J Clin Pathol; 2003 May 01; 56(5):385-8. PubMed ID: 12719461 [Abstract] [Full Text] [Related]
58. Evaluation of the BD Vacutainer Plus Urine C&S Preservative Tubes compared with nonpreservative urine samples stored at 4°C and room temperature. Eisinger SW, Schwartz M, Dam L, Riedel S. Am J Clin Pathol; 2013 Sep 01; 140(3):306-13. PubMed ID: 23955448 [Abstract] [Full Text] [Related]
59. Underfilling of vacuum blood collection tubes leads to increased lactate dehydrogenase activity in serum and heparin plasma samples. Neuwinger N, Meyer Zum Büschenfelde D, Tauber R, Kappert K. Clin Chem Lab Med; 2020 Jan 28; 58(2):213-221. PubMed ID: 31665108 [Abstract] [Full Text] [Related]
60. Pseudohyperkalaemia associated with leukaemic cell lysis during pneumatic tube transport of blood samples. Dickinson H, Webb NJ, Chaloner C, Wynn RF, Bonney DK. Pediatr Nephrol; 2012 Jun 28; 27(6):1029-31. PubMed ID: 22366875 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]