These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
237 related items for PubMed ID: 23897107
61. Could S-Monovette Serum Gel Tubes be Used for Clinical Chemistry Analysis Instead of Serum Separator Tube II Advance? Cat A, Ucar KT, Nurlu N. Clin Lab; 2022 Apr 01; 68(4):. PubMed ID: 35443592 [Abstract] [Full Text] [Related]
62. A comparison of glucose concentration in paired specimens collected in serum separator and fluoride/potassium oxalate blood collection tubes under survey 'field' conditions. Fernandez L, Jee P, Klein MJ, Fischer P, Perkins SL, Brooks SP. Clin Biochem; 2013 Mar 01; 46(4-5):285-8. PubMed ID: 23219741 [Abstract] [Full Text] [Related]
63. Implementation of biological variation-based analytical performance specifications in the laboratory: Stringent evaluation of Improvacutor blood collection tubes. Chung HJ, Song YK, Hong SK, Hwang SH, Seo HS, Whang DH, Nam MH, Lee DH. PLoS One; 2017 Mar 01; 12(12):e0189882. PubMed ID: 29261759 [Abstract] [Full Text] [Related]
65. [Must we always treat hyperkalaemia?]. Basile C, Manobianca G, Bruno A, Tamma F. G Ital Nefrol; 2013 Jul 01; 30(1):. PubMed ID: 23832444 [Abstract] [Full Text] [Related]
66. Barricor blood collection tubes are equivalent to PST for a variety of chemistry and immunoassay analytes except for lactate dehydrogenase. Raizman JE, Goudreau BL, Füzéry AK, Cembrowski GS. Clin Chim Acta; 2019 Sep 01; 496():18-24. PubMed ID: 31201816 [Abstract] [Full Text] [Related]
67. Evaluation of Pain and Specimen Quality by Use of a Novel 25-Gauge Blood Collection Set With Ultra-Thin Wall Cannula and 5-Bevel Tip Design. Mouser A, Uettwiller-Geiger D, Plokhoy E, Berube J, Ahuja AJ, Stankovic AK. J Appl Lab Med; 2017 Sep 01; 2(2):201-210. PubMed ID: 32630975 [Abstract] [Full Text] [Related]
68. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes. Böckel-Frohnhöfer N, Hübner U, Hummel B, Geisel J. Scand J Clin Lab Invest; 2014 Oct 01; 74(7):599-602. PubMed ID: 24909156 [Abstract] [Full Text] [Related]
69. Retrospective analysis of intra-patient laboratory variation demonstrates that the BD Vacutainer® Barricor™ blood collection tube reduces troponin variation. Cembrowski G, Qiu Y, Sherazi A, Shea JL. Clin Biochem; 2023 Apr 01; 114():24-29. PubMed ID: 36706798 [Abstract] [Full Text] [Related]
70. Improved quality of samples and laboratory turnaround time using 3.5 mL low vacuum BD Vacutainer® Barricor tubes in the emergency department. Badiou S, Vuillot O, Bargnoux AS, Kuster N, Lefebvre S, Sebbane M, Cristol JP, Dupuy AM. Pract Lab Med; 2019 Aug 01; 16():e00128. PubMed ID: 31289734 [Abstract] [Full Text] [Related]
71. Measurement of organochlorine levels in postprandial serum or in blood collected in serum separator tubes. Longnecker MP, Bernstein L, Bird CL, Yancey AK, Peterson JC. Cancer Epidemiol Biomarkers Prev; 1996 Sep 01; 5(9):753-5. PubMed ID: 8877068 [Abstract] [Full Text] [Related]
72. Reduction of gross hemolysis in catheter-drawn blood using Greiner Holdex tube holder. Lippi G, Avanzini P, Aloe R, Cervellin G. Biochem Med (Zagreb); 2013 Sep 01; 23(3):303-7. PubMed ID: 24266299 [Abstract] [Full Text] [Related]
73. Potassium but not lactate dehydrogenase elevation due to in vitro hemolysis is higher in capillary than in venous blood samples. Oostendorp M, van Solinge WW, Kemperman H. Arch Pathol Lab Med; 2012 Oct 01; 136(10):1262-5. PubMed ID: 23020733 [Abstract] [Full Text] [Related]
74. Switching from serum to plasma: Implementation of BD Vacutainer® Barricor™ Plasma Blood Collection Tubes improves sample quality and laboratory turnaround time. Ramakers C, Meyer B, Yang W, Plokhoy E, Xiong Y, Church S, Kaushik N. Pract Lab Med; 2020 Jan 01; 18():e00149. PubMed ID: 31909146 [Abstract] [Full Text] [Related]
75. Pseudometabolic acidosis caused by underfill of Vacutainer tubes. Herr RD, Swanson T. Ann Emerg Med; 1992 Feb 01; 21(2):177-80. PubMed ID: 1739211 [Abstract] [Full Text] [Related]
76. Stabilization of Plasma Glucose: The Use of Newer Technology and Pragmatic Laboratory Practice. Coward SM, O'Neill FC, McAdam L, Reilly L, McKeeman GC. J Appl Lab Med; 2019 May 01; 3(6):1028-1034. PubMed ID: 31639694 [Abstract] [Full Text] [Related]
77. Is Prevention of Hemolysis Possible in Blood Samples Collected from IV catheters in the Emergency Department? Cakir MO, Yildiz Z, Orcun A, Hurmeydan O, Yilmaz E. Clin Lab; 2021 Jul 01; 67(7):. PubMed ID: 34258964 [Abstract] [Full Text] [Related]
78. Introduction of BD Vacutainer® Barricor™ tubes in clinical biobanking and application of amino acid and cytokine quality indicators to Barricor plasma. Knutti N, Neugebauer S, Scherr F, Mathay C, Marchese M, Henry E, Palm J, Betsou F, Kiehntopf M. Clin Chem Lab Med; 2022 Apr 26; 60(5):689-700. PubMed ID: 35073617 [Abstract] [Full Text] [Related]
79. Effects of sample handling on total carbon dioxide concentrations in canine and feline serum and blood. James KM, Polzin DJ, Osborne CA, Olson JK. Am J Vet Res; 1997 Apr 26; 58(4):343-7. PubMed ID: 9099375 [Abstract] [Full Text] [Related]
80. Biochemical, immunochemical and serology analytes validation of the lithium heparin BD Barricor blood collection tube on a highly automated Roche COBAS8000 instrument. Ferrari D, Strollo M, Vidali M, Motta A, Pontillo M, Locatelli M. Acta Biomed; 2020 Mar 19; 91(1):47-55. PubMed ID: 32191654 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]