These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
402 related items for PubMed ID: 23945890
1. Comparison of prophylactic effects of polyurethane cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes on ventilator-associated pneumonia. Mahmoodpoor A, Peyrovi-far A, Hamishehkar H, Bakhtyiari Z, Mirinezhad MM, Hamidi M, Golzari SE. Acta Med Iran; 2013 Aug 07; 51(7):461-6. PubMed ID: 23945890 [Abstract] [Full Text] [Related]
2. Influence of an endotracheal tube with polyurethane cuff and subglottic secretion drainage on pneumonia. Lorente L, Lecuona M, Jiménez A, Mora ML, Sierra A. Am J Respir Crit Care Med; 2007 Dec 01; 176(11):1079-83. PubMed ID: 17872488 [Abstract] [Full Text] [Related]
3. The value of polyurethane-cuffed endotracheal tubes to reduce microaspiration and intubation-related pneumonia: a systematic review of laboratory and clinical studies. Blot SI, Rello J, Koulenti D. Crit Care; 2016 Jun 24; 20(1):203. PubMed ID: 27342802 [Abstract] [Full Text] [Related]
4. Performance of the PneuX System: A Bench Study Comparison With 4 Other Endotracheal Tube Cuffs. Chenelle CT, Itagaki T, Fisher DF, Berra L, Kacmarek RM. Respir Care; 2017 Jan 24; 62(1):102-112. PubMed ID: 27879379 [Abstract] [Full Text] [Related]
5. Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: a pilot study. Poelaert J, Depuydt P, De Wolf A, Van de Velde S, Herck I, Blot S. J Thorac Cardiovasc Surg; 2008 Apr 24; 135(4):771-6. PubMed ID: 18374755 [Abstract] [Full Text] [Related]
6. Benchtop study of leakages across the Portex, TaperGuard, and Microcuff endotracheal tubes under simulated clinical conditions. Lau AC, Lam SM, Yan WW. Hong Kong Med J; 2014 Feb 24; 20(1):7-15. PubMed ID: 23878202 [Abstract] [Full Text] [Related]
7. The impact of hospital-wide use of a tapered-cuff endotracheal tube on the incidence of ventilator-associated pneumonia. Bowton DL, Hite RD, Martin RS, Sherertz R. Respir Care; 2013 Oct 24; 58(10):1582-7. PubMed ID: 23431308 [Abstract] [Full Text] [Related]
11. Tapered-cuff Endotracheal Tube Does Not Prevent Early Postoperative Pneumonia Compared with Spherical-cuff Endotracheal Tube after Major Vascular Surgery: A Randomized Controlled Trial. Monsel A, Lu Q, Le Corre M, Brisson H, Arbelot C, Vezinet C, Fléron MH, Ibanez-Estève C, Zerimech F, Balduyck M, Dexheimer F, Wang C, Langeron O, Rouby JJ, Bodin L, Deransy R, Garçon P, Douiri H, Khalifa I, Pons A, Gu WJ, Koskas F, Gaudric J, TETRIS Study Group. Anesthesiology; 2016 May 24; 124(5):1041-52. PubMed ID: 26872366 [Abstract] [Full Text] [Related]
12. Polyurethane does not protect better than polyvinyl cuffed tracheal tubes from microaspirations. Bulpa P, Evrard P, Bouhon S, Schryvers F, Jamart J, Michaux I, Dive A, Vander Borght T, Krug B. Minerva Anestesiol; 2013 May 24; 79(5):498-503. PubMed ID: 23511349 [Abstract] [Full Text] [Related]
13. Randomized Pilot Trial of Two Modified Endotracheal Tubes To Prevent Ventilator-associated Pneumonia. Deem S, Yanez D, Sissons-Ross L, Broeckel JA, Daniel S, Treggiari M. Ann Am Thorac Soc; 2016 Jan 24; 13(1):72-80. PubMed ID: 26523433 [Abstract] [Full Text] [Related]
14. Impact of tracheal cuff shape on microaspiration of gastric contents in intubated critically ill patients: study protocol for a randomized controlled trial. Jaillette E, Brunin G, Girault C, Zerimech F, Chiche A, Broucqsault-Dedrie C, Fayolle C, Minacori F, Alves I, Barrailler S, Robriquet L, Tamion F, Delaporte E, Thellier D, Delcourte C, Duhamel A, Nseir S. Trials; 2015 Sep 25; 16():429. PubMed ID: 26407612 [Abstract] [Full Text] [Related]