These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
344 related items for PubMed ID: 24105679
1. Usefulness of the SPACE pulse sequence at 1.5T MR cholangiography: comparison of image quality and image acquisition time with conventional 3D-TSE sequence. Nakaura T, Kidoh M, Maruyama N, Kawahara T, Namimoto T, Sakai Y, Harada K, Yamashita Y. J Magn Reson Imaging; 2013 Nov; 38(5):1014-9. PubMed ID: 24105679 [Abstract] [Full Text] [Related]
3. Comparison of Optimized 3D-SPACE and 3D-TSE Sequences at 1.5T MRCP in the Diagnosis of Choledocholithiasis. Sudholt P, Zaehringer C, Urigo C, Tyndall A, Bongartz G, Hohmann J. Rofo; 2015 Jun; 187(6):467-71. PubMed ID: 25877993 [Abstract] [Full Text] [Related]
12. Comparison of SPACE and 3D TSE MRCP at 1.5T focusing on difference in echo spacing. Morita S, Ueno E, Masukawa A, Suzuki K, Machida H, Fujimura M, Kojima S, Hirata M, Ohnishi T, Kitajima K, Kaji Y. Magn Reson Med Sci; 2009 Nov; 8(3):101-5. PubMed ID: 19783873 [Abstract] [Full Text] [Related]
13. MRI of the lumbar spine: comparison of 3D isotropic turbo spin-echo SPACE sequence versus conventional 2D sequences at 3.0 T. Lee S, Jee WH, Jung JY, Lee SY, Ryu KS, Ha KY. Acta Radiol; 2015 Feb; 56(2):174-81. PubMed ID: 24553584 [Abstract] [Full Text] [Related]
14. Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: does it improve image quality and acquisition time as compared with 3D TSE? Yoshida M, Nakaura T, Inoue T, Tanoue S, Takada S, Utsunomiya D, Tsumagari S, Harada K, Yamashita Y. Eur Radiol; 2018 Jun; 28(6):2436-2443. PubMed ID: 29335869 [Abstract] [Full Text] [Related]
17. 3D-MRI of the ankle with optimized 3D-SPACE. Notohamiprodjo M, Kuschel B, Horng A, Paul D, Baer P, Li G, Garcia del Olmo JM, Reiser MF, Glaser C. Invest Radiol; 2012 Apr; 47(4):231-9. PubMed ID: 22373531 [Abstract] [Full Text] [Related]
18. Biliary anatomy on 3D MRCP: Comparison of volume-rendering and maximum-intensity-projection algorithms. Morita S, Saito N, Suzuki K, Mitsuhashi N. J Magn Reson Imaging; 2009 Mar; 29(3):601-6. PubMed ID: 19243055 [Abstract] [Full Text] [Related]
19. Three-Dimensional Breath-Hold MRCP Using SPACE Pulse Sequence at 3 T: Comparison With Conventional Navigator-Triggered Technique. Chen Z, Sun B, Duan Q, Xue Y, Zheng E, He Y, Li G. AJR Am J Roentgenol; 2019 Dec; 213(6):1247-1252. PubMed ID: 31386572 [Abstract] [Full Text] [Related]