These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
374 related items for PubMed ID: 24401399
1. A novel sensitive doxorubicin impedimetric immunosensor based on a specific monoclonal antibody-gold nanoaprticle-sol-gel modified electrode. Rezaei B, Askarpour N, Ensafi AA. Talanta; 2014 Feb; 119():164-9. PubMed ID: 24401399 [Abstract] [Full Text] [Related]
2. Stainless steel modified with an aminosilane layer and gold nanoparticles as a novel disposable substrate for impedimetric immunosensors. Rezaei B, Havakeshian E, Ensafi AA. Biosens Bioelectron; 2013 Oct 15; 48():61-6. PubMed ID: 23648687 [Abstract] [Full Text] [Related]
3. Electrochemical impedimetric immunosensor for insulin like growth factor-1 using specific monoclonal antibody-nanogold modified electrode. Rezaei B, Majidi N, Rahmani H, Khayamian T. Biosens Bioelectron; 2011 Jan 15; 26(5):2130-4. PubMed ID: 20933383 [Abstract] [Full Text] [Related]
4. Multiwall carbon nanotube-ionic liquid electrode modified with gold nanoparticles as a base for preparation of a novel impedimetric immunosensor for low level detection of human serum albumin in biological fluids. Arkan E, Saber R, Karimi Z, Mostafaie A, Shamsipur M. J Pharm Biomed Anal; 2014 Apr 15; 92():74-81. PubMed ID: 24503195 [Abstract] [Full Text] [Related]
5. A novel antibody-antigen based impedimetric immunosensor for low level detection of HER2 in serum samples of breast cancer patients via modification of a gold nanoparticles decorated multiwall carbon nanotube-ionic liquid electrode. Arkan E, Saber R, Karimi Z, Shamsipur M. Anal Chim Acta; 2015 May 18; 874():66-74. PubMed ID: 25910448 [Abstract] [Full Text] [Related]
6. AFM, CLSM and EIS characterization of the immobilization of antibodies on indium-tin oxide electrode and their capture of Legionella pneumophila. Souiri M, Blel N, Sboui D, Mhamdi L, Epalle T, Mzoughi R, Riffard S, Othmane A. Talanta; 2014 Jan 18; 118():224-30. PubMed ID: 24274292 [Abstract] [Full Text] [Related]
7. Immobilization of specific monoclonal antibody on Au nanoparticles for hGH detection by electrochemical impedance spectroscopy. Rezaei B, Khayamian T, Majidi N, Rahmani H. Biosens Bioelectron; 2009 Oct 15; 25(2):395-9. PubMed ID: 19692224 [Abstract] [Full Text] [Related]
8. Impedimetric immunosensor for the label-free and direct detection of botulinum neurotoxin serotype A using Au nanoparticles/graphene-chitosan composite. Afkhami A, Hashemi P, Bagheri H, Salimian J, Ahmadi A, Madrakian T. Biosens Bioelectron; 2017 Jul 15; 93():124-131. PubMed ID: 27665169 [Abstract] [Full Text] [Related]
9. A novel lable-free electrochemical immunosensor for carcinoembryonic antigen based on gold nanoparticles-thionine-reduced graphene oxide nanocomposite film modified glassy carbon electrode. Kong FY, Xu MT, Xu JJ, Chen HY. Talanta; 2011 Oct 15; 85(5):2620-5. PubMed ID: 21962692 [Abstract] [Full Text] [Related]
10. Electrochemical impedance immunosensor based on gold nanoparticles and aryl diazonium salt functionalized gold electrodes for the detection of antibody. Liu G, Liu J, Davis TP, Gooding JJ. Biosens Bioelectron; 2011 Apr 15; 26(8):3660-5. PubMed ID: 21398105 [Abstract] [Full Text] [Related]
11. Femtomolar detection of cardiac troponin I using a novel label-free and reagent-free dendrimer enhanced impedimetric immunosensor. Akter R, Jeong B, Lee YM, Choi JS, Rahman MA. Biosens Bioelectron; 2017 May 15; 91():637-643. PubMed ID: 28107745 [Abstract] [Full Text] [Related]
12. Amperometric immunosensor based on gold nanoparticles/alumina sol-gel modified screen-printed electrodes for antibodies to Plasmodium falciparum histidine rich protein-2. Sharma MK, Agarwal GS, Rao VK, Upadhyay S, Merwyn S, Gopalan N, Rai GP, Vijayaraghavan R, Prakash S. Analyst; 2010 Mar 15; 135(3):608-14. PubMed ID: 20174718 [Abstract] [Full Text] [Related]
13. Electrochemical immunosensor for botulinum neurotoxin type-E using covalently ordered graphene nanosheets modified electrodes and gold nanoparticles-enzyme conjugate. Narayanan J, Sharma MK, Ponmariappan S, Sarita, Shaik M, Upadhyay S. Biosens Bioelectron; 2015 Jul 15; 69():249-56. PubMed ID: 25754919 [Abstract] [Full Text] [Related]
14. An impedimetric immunosensor for highly sensitive detection of IL-8 in human serum and saliva samples: A new surface modification method by 6-phosphonohexanoic acid for biosensing applications. Aydın EB, Sezgintürk MK. Anal Biochem; 2018 Aug 01; 554():44-52. PubMed ID: 29902421 [Abstract] [Full Text] [Related]
15. Supported protein G on gold electrode: characterization and immunosensor application. Hafaiedh I, Chammem H, Abdelghani A, Ait E, Feldman L, Meilhac O, Mora L. Talanta; 2013 Nov 15; 116():84-90. PubMed ID: 24148377 [Abstract] [Full Text] [Related]
16. Ultrasensitive electrochemical immunosensor for HE4 based on rolling circle amplification. Lu L, Liu B, Zhao Z, Ma C, Luo P, Liu C, Xie G. Biosens Bioelectron; 2012 Mar 15; 33(1):216-21. PubMed ID: 22305445 [Abstract] [Full Text] [Related]
17. Ultrasensitive potentiometric immunosensor based on SA and OCA techniques for immobilization of HBsAb with colloidal Au and polyvinyl butyral as matrixes. Yuan R, Tang D, Chai Y, Zhong X, Liu Y, Dai J. Langmuir; 2004 Aug 17; 20(17):7240-5. PubMed ID: 15301511 [Abstract] [Full Text] [Related]
18. An ultra-sensitive impedimetric immunosensor for detection of the serum oncomarker CA-125 in ovarian cancer patients. Johari-Ahar M, Rashidi MR, Barar J, Aghaie M, Mohammadnejad D, Ramazani A, Karami P, Coukos G, Omidi Y. Nanoscale; 2015 Feb 28; 7(8):3768-79. PubMed ID: 25644549 [Abstract] [Full Text] [Related]
19. Myelin basic protein immunosensor for multiple sclerosis detection based upon label-free electrochemical impedance spectroscopy. Derkus B, Emregul E, Yucesan C, Cebesoy Emregul K. Biosens Bioelectron; 2013 Aug 15; 46():53-60. PubMed ID: 23500477 [Abstract] [Full Text] [Related]
20. A regenerating ultrasensitive electrochemical impedance immunosensor for the detection of adenovirus. Lin D, Tang T, Jed Harrison D, Lee WE, Jemere AB. Biosens Bioelectron; 2015 Jun 15; 68():129-134. PubMed ID: 25562739 [Abstract] [Full Text] [Related] Page: [Next] [New Search]