These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


1373 related items for PubMed ID: 24446022

  • 1. Incidence and significance of early recurrences of atrial fibrillation after cryoballoon ablation: insights from the multicenter Sustained Treatment of Paroxysmal Atrial Fibrillation (STOP AF) Trial.
    Andrade JG, Khairy P, Macle L, Packer DL, Lehmann JW, Holcomb RG, Ruskin JN, Dubuc M.
    Circ Arrhythm Electrophysiol; 2014 Feb; 7(1):69-75. PubMed ID: 24446022
    [Abstract] [Full Text] [Related]

  • 2. Clinical significance of early recurrence after pulmonary vein antrum isolation in paroxysmal atrial fibrillation -- insight into the mechanism.
    Miyazaki S, Taniguchi H, Nakamura H, Takagi T, Iwasawa J, Hachiya H, Iesaka Y.
    Circ J; 2015 Feb; 79(11):2353-9. PubMed ID: 26346285
    [Abstract] [Full Text] [Related]

  • 3. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial.
    Packer DL, Kowal RC, Wheelan KR, Irwin JM, Champagne J, Guerra PG, Dubuc M, Reddy V, Nelson L, Holcomb RG, Lehmann JW, Ruskin JN, STOP AF Cryoablation Investigators.
    J Am Coll Cardiol; 2013 Apr 23; 61(16):1713-23. PubMed ID: 23500312
    [Abstract] [Full Text] [Related]

  • 4. Influence of energy source on early atrial fibrillation recurrences: a comparison of cryoballoon vs. radiofrequency current energy ablation with the endpoint of unexcitability in pulmonary vein isolation.
    Gunawardene MA, Hoffmann BA, Schaeffer B, Chung DU, Moser J, Akbulak RO, Jularic M, Eickholt C, Nuehrich J, Meyer C, Willems S.
    Europace; 2018 Jan 01; 20(1):43-49. PubMed ID: 27742775
    [Abstract] [Full Text] [Related]

  • 5. Cryoballoon versus radiofrequency for pulmonary vein re-isolation after a failed initial ablation procedure in patients with paroxysmal atrial fibrillation.
    Pokushalov E, Romanov A, Artyomenko S, Baranova V, Losik D, Bairamova S, Karaskov A, Mittal S, Steinberg JS.
    J Cardiovasc Electrophysiol; 2013 Mar 01; 24(3):274-9. PubMed ID: 23210695
    [Abstract] [Full Text] [Related]

  • 6. Progression of atrial fibrillation after a failed initial ablation procedure in patients with paroxysmal atrial fibrillation: a randomized comparison of drug therapy versus reablation.
    Pokushalov E, Romanov A, De Melis M, Artyomenko S, Baranova V, Losik D, Bairamova S, Karaskov A, Mittal S, Steinberg JS.
    Circ Arrhythm Electrophysiol; 2013 Aug 01; 6(4):754-60. PubMed ID: 23748210
    [Abstract] [Full Text] [Related]

  • 7. Results from a multicentre comparison of cryoballoon vs. radiofrequency ablation for paroxysmal atrial fibrillation: is cryoablation more reproducible?
    Providencia R, Defaye P, Lambiase PD, Pavin D, Cebron JP, Halimi F, Anselme F, Srinivasan N, Albenque JP, Boveda S.
    Europace; 2017 Jan 01; 19(1):48-57. PubMed ID: 27267554
    [Abstract] [Full Text] [Related]

  • 8. Use of an implantable monitor to detect arrhythmia recurrences and select patients for early repeat catheter ablation for atrial fibrillation: a pilot study.
    Pokushalov E, Romanov A, Corbucci G, Artyomenko S, Turov A, Shirokova N, Karaskov A.
    Circ Arrhythm Electrophysiol; 2011 Dec 01; 4(6):823-31. PubMed ID: 21930653
    [Abstract] [Full Text] [Related]

  • 9. Predictors of atrial fibrillation recurrence after atrial fibrillation ablation with cryoballoon.
    Evranos B, Aytemir K, Oto A, Okutucu S, Karakulak U, Şahiner L, Kaya B, Kabakçı G.
    Cardiol J; 2013 Dec 01; 20(3):294-303. PubMed ID: 23788304
    [Abstract] [Full Text] [Related]

  • 10. Atrial ectopy predicts late recurrence of atrial fibrillation after pulmonary vein isolation.
    Gang UJ, Nalliah CJ, Lim TW, Thiagalingam A, Kovoor P, Ross DL, Thomas SP.
    Circ Arrhythm Electrophysiol; 2015 Jun 01; 8(3):569-74. PubMed ID: 25904494
    [Abstract] [Full Text] [Related]

  • 11. Analysis of risk factors for recurrence after video-assisted pulmonary vein isolation of lone atrial fibrillation--results of 5 years of follow-up.
    Hu QM, Li Y, Xu CL, Han J, Zhang HB, Han W, Meng X.
    J Thorac Cardiovasc Surg; 2014 Nov 01; 148(5):2174-80. PubMed ID: 24698564
    [Abstract] [Full Text] [Related]

  • 12. Ablation of atrial fibrillation with cryoballoon or duty-cycled radiofrequency pulmonary vein ablation catheter: a randomized controlled study comparing the clinical outcome and safety; the AF-COR study.
    Malmborg H, Lönnerholm S, Blomström P, Blomström-Lundqvist C.
    Europace; 2013 Nov 01; 15(11):1567-73. PubMed ID: 23703361
    [Abstract] [Full Text] [Related]

  • 13. Selective complex fractionated atrial electrograms targeting for atrial fibrillation study (SELECT AF): a multicenter, randomized trial.
    Verma A, Sanders P, Champagne J, Macle L, Nair GM, Calkins H, Wilber DJ.
    Circ Arrhythm Electrophysiol; 2014 Feb 01; 7(1):55-62. PubMed ID: 24425420
    [Abstract] [Full Text] [Related]

  • 14. Prevalence and outcome of early recurrence of atrial tachyarrhythmias in the Cryoballoon vs Irrigated Radiofrequency Catheter Ablation (CIRCA-DOSE) study.
    Steinberg C, Champagne J, Deyell MW, Dubuc M, Leong-Sit P, Calkins H, Sterns L, Badra-Verdu M, Sapp J, Macle L, Khairy P, Andrade JG, CIRCA-DOSE Study Investigators.
    Heart Rhythm; 2021 Sep 01; 18(9):1463-1470. PubMed ID: 34126269
    [Abstract] [Full Text] [Related]

  • 15. Diffuse ventricular fibrosis measured by T₁ mapping on cardiac MRI predicts success of catheter ablation for atrial fibrillation.
    McLellan AJ, Ling LH, Azzopardi S, Ellims AH, Iles LM, Sellenger MA, Morton JB, Kalman JM, Taylor AJ, Kistler PM.
    Circ Arrhythm Electrophysiol; 2014 Oct 01; 7(5):834-40. PubMed ID: 25141860
    [Abstract] [Full Text] [Related]

  • 16. Is pursuit of termination of atrial fibrillation during catheter ablation of great value in patients with longstanding persistent atrial fibrillation?
    Park YM, Choi JI, Lim HE, Park SW, Kim YH.
    J Cardiovasc Electrophysiol; 2012 Oct 01; 23(10):1051-8. PubMed ID: 22882600
    [Abstract] [Full Text] [Related]

  • 17. The role of preprocedural monocyte-to-high-density lipoprotein ratio in prediction of atrial fibrillation recurrence after cryoballoon-based catheter ablation.
    Canpolat U, Aytemir K, Yorgun H, Şahiner L, Kaya EB, Çay S, Topaloğlu S, Aras D, Oto A.
    Europace; 2015 Dec 01; 17(12):1807-15. PubMed ID: 25995388
    [Abstract] [Full Text] [Related]

  • 18. Outcomes after cryoablation vs. radiofrequency in patients with paroxysmal atrial fibrillation: impact of pulmonary veins anatomy.
    Khoueiry Z, Albenque JP, Providencia R, Combes S, Combes N, Jourda F, Sousa PA, Cardin C, Pasquie JL, Cung TT, Massin F, Marijon E, Boveda S.
    Europace; 2016 Sep 01; 18(9):1343-51. PubMed ID: 26817755
    [Abstract] [Full Text] [Related]

  • 19. Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation.
    Squara F, Zhao A, Marijon E, Latcu DG, Providencia R, Di Giovanni G, Jauvert G, Jourda F, Chierchia GB, De Asmundis C, Ciconte G, Alonso C, Grimard C, Boveda S, Cauchemez B, Saoudi N, Brugada P, Albenque JP, Thomas O.
    Europace; 2015 May 01; 17(5):718-24. PubMed ID: 25840289
    [Abstract] [Full Text] [Related]

  • 20. Comparison of CHADS2, R2CHADS2, and CHA2DS2-VASc scores for the prediction of rhythm outcomes after catheter ablation of atrial fibrillation: the Leipzig Heart Center AF Ablation Registry.
    Kornej J, Hindricks G, Kosiuk J, Arya A, Sommer P, Husser D, Rolf S, Richter S, Huo Y, Piorkowski C, Bollmann A.
    Circ Arrhythm Electrophysiol; 2014 Apr 01; 7(2):281-7. PubMed ID: 24610790
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 69.