These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


493 related items for PubMed ID: 24517734

  • 1. Comparison of two handheld applanation tonometers and the association of central corneal thickness, age, and intraocular pressure in normal and diseased canine eyes.
    Kato K.
    Vet Ophthalmol; 2014 Nov; 17(6):417-25. PubMed ID: 24517734
    [Abstract] [Full Text] [Related]

  • 2. Clinical comparison of the TonoVet(®) rebound tonometer and the Tono-Pen Vet(®) applanation tonometer in dogs and cats with ocular disease: glaucoma or corneal pathology.
    von Spiessen L, Karck J, Rohn K, Meyer-Lindenberg A.
    Vet Ophthalmol; 2015 Jan; 18(1):20-7. PubMed ID: 24131625
    [Abstract] [Full Text] [Related]

  • 3. Comparison of intraocular pressure measurements between the Tono-Pen XL® and Perkins® applanation tonometers in dogs and cats.
    Andrade SF, Palozzi RJ, Giuffrida R, de Campos RJ, Santos Gde C, Fukui RM.
    Vet Ophthalmol; 2012 Mar; 15 Suppl 1():14-20. PubMed ID: 22050624
    [Abstract] [Full Text] [Related]

  • 4.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 5. Positive correlation between Tono-Pen intraocular pressure and central corneal thickness.
    Dohadwala AA, Munger R, Damji KF.
    Ophthalmology; 1998 Oct; 105(10):1849-54. PubMed ID: 9787354
    [Abstract] [Full Text] [Related]

  • 6. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen.
    Bhan A, Browning AC, Shah S, Hamilton R, Dave D, Dua HS.
    Invest Ophthalmol Vis Sci; 2002 May; 43(5):1389-92. PubMed ID: 11980851
    [Abstract] [Full Text] [Related]

  • 7. The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.
    Browning AC, Bhan A, Rotchford AP, Shah S, Dua HS.
    Br J Ophthalmol; 2004 Nov; 88(11):1395-9. PubMed ID: 15489480
    [Abstract] [Full Text] [Related]

  • 8.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 9. Comparison of Intraocular Pressure Measurements between Icare Pro Rebound Tonometer and Tono-Pen XL Tonometer in Supine and Lateral Decubitus Body Positions.
    Lee TE, Yoo C, Hwang JY, Lin S, Kim YY.
    Curr Eye Res; 2015 Sep; 40(9):923-9. PubMed ID: 25271991
    [Abstract] [Full Text] [Related]

  • 10. The impact of corneal edema on intraocular pressure measurements using goldmann applanation tonometry, Tono-Pen XL, iCare, and ORA: an in vitro model.
    Neuburger M, Maier P, Böhringer D, Reinhard T, F Jordan J.
    J Glaucoma; 2013 Sep; 22(7):584-90. PubMed ID: 22366704
    [Abstract] [Full Text] [Related]

  • 11. Comparison of a rebound tonometer with an applanation tonometer in dogs with glaucoma.
    Slack JM, Stiles J, Moore GE.
    Vet Rec; 2012 Oct 13; 171(15):373. PubMed ID: 22915681
    [Abstract] [Full Text] [Related]

  • 12. [How does central cornea thickness influence intraocular pressure during applanation and contour tonometry?].
    Schwenteck T, Knappe M, Moros I.
    Klin Monbl Augenheilkd; 2012 Sep 13; 229(9):917-27. PubMed ID: 22972357
    [Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14. Corneal modulus and IOP measurements in canine eyes using Goldmann applanation tonometry and Tono-pen.
    Tang J, Pan X, Weber PA, Liu J.
    Invest Ophthalmol Vis Sci; 2011 Oct 04; 52(11):7866-71. PubMed ID: 21896862
    [Abstract] [Full Text] [Related]

  • 15. Tono-Pen tonometer and corneal thickness.
    Mok KH, Wong CS, Lee VW.
    Eye (Lond); 1999 Oct 04; 13 ( Pt 1)():35-7. PubMed ID: 10396381
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17. Variations of Intraocular Pressure Measured by Goldmann Applanation Tonometer, Tono-Pen, iCare Rebound Tonometer, and Pascal Dynamic Contour Tonometer in Patients With Corneal Edema After Phacoemulsification.
    Kiddee W, Tanjana A.
    J Glaucoma; 2021 Apr 01; 30(4):317-324. PubMed ID: 33137014
    [Abstract] [Full Text] [Related]

  • 18. Effect of corneal stiffening on Goldmann applanation tonometry and Tono-Pen measurements in canine eyes.
    Tang J, Pan X, Weber PA, Liu J.
    Invest Ophthalmol Vis Sci; 2012 Mar 15; 53(3):1397-405. PubMed ID: 22297494
    [Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20. Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes.
    García-Resúa C, González-Meijome JM, Gilino J, Yebra-Pimentel E.
    Optom Vis Sci; 2006 Feb 15; 83(2):102-7. PubMed ID: 16501412
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 25.