706 related items for PubMed ID: 24571497
1. An algorithmic programming approach for back pain symptoms in failed back surgery syndrome using spinal cord stimulation with a multicolumn surgically implanted epidural lead: a multicenter international prospective study. Rigoard P, Jacques L, Delmotte A, Poon K, Munson R, Monlezun O, Roulaud M, Prevost A, Guetarni F, Bataille B, Kumar K. Pain Pract; 2015 Mar; 15(3):195-207. PubMed ID: 24571497 [Abstract] [Full Text] [Related]
2. The Franco-Canadian multicolumn spinal cord stimulation prospective study: a subgroup analysis focusing on the decisive role of lead positioning. Delmotte A, Jacques L, Kumar K, Poon K, Monlezun O, Roulaud M, Prevost A, Munson R, Guetarni F, Bataille B, Rigoard P. Neurochirurgie; 2015 Mar; 61 Suppl 1():S83-9. PubMed ID: 25245918 [Abstract] [Full Text] [Related]
4. A prospective study evaluating sleep quality in Failed Back Surgery Syndrome patients treated by multicolumn spinal cord stimulation: study design protocol and presentation of the study population. Monlezun O, Lode-Kolz K, Roulaud M, Paquereau J, Ingrand P, Veyrieras C, Brandet C, Guetarni F, Prévost A, Bataille B, Rigoard P, le groupe Estimet. Neurochirurgie; 2015 Mar; 61 Suppl 1():S117-24. PubMed ID: 25245920 [Abstract] [Full Text] [Related]
5. How Should we Use Multicolumn Spinal Cord Stimulation to Optimize Back Pain Spatial Neural Targeting? A Prospective, Multicenter, Randomized, Double-Blind, Controlled Trial (ESTIMET Study). Rigoard P, Billot M, Ingrand P, Durand-Zaleski I, Roulaud M, Peruzzi P, Dam Hieu P, Voirin J, Raoul S, Page P, Djian MC, Fontaine D, Lantéri-Minet M, Blond S, Buisset N, Cuny E, Cadenne M, Caire F, Ranoux D, Mertens P, Naous H, Simon E, Emery E, Béraud G, Debiais F, Durand G, Serrie A, Diallo B, Bulsei J, Ounajim A, Nivole K, Duranton S, Naiditch N, Monlezun O, Bataille B. Neuromodulation; 2021 Jan; 24(1):86-101. PubMed ID: 32865344 [Abstract] [Full Text] [Related]
6. Evaluation of the Effectiveness of Percutaneous Octapolar Leads in Pain Treatment with Spinal Cord Stimulation of Patients with Failed Back Surgery Syndrome During a 1-Year Follow-Up: A Prospective Multicenter International Study. Gatzinsky K, Baardsen R, Buschman HP. Pain Pract; 2017 Apr; 17(4):428-437. PubMed ID: 27435009 [Abstract] [Full Text] [Related]
7. Back pain: a real target for spinal cord stimulation? Rigoard P, Delmotte A, D'Houtaud S, Misbert L, Diallo B, Roy-Moreau A, Durand S, Royoux S, Giot JP, Bataille B. Neurosurgery; 2012 Mar; 70(3):574-84; discussion 584-5. PubMed ID: 21937929 [Abstract] [Full Text] [Related]
8. Effect of Multicolumn Lead Spinal Cord Stimulation on Low Back Pain in Failed Back Surgery Patients: A Three-Year Follow-Up. Remacle TY, Bonhomme VL, Renwart HP, Remacle JM. Neuromodulation; 2017 Oct; 20(7):668-674. PubMed ID: 28464357 [Abstract] [Full Text] [Related]
9. Long-Term Multicolumn-Lead Spinal Cord Stimulation Efficacy in Patients with Failed Back Surgery Syndrome: A Six-Year Prospective Follow-up Study. Remacle T, Mauviel S, Renwart HJ, Ghassempour K, Belle F, Lückers O, Bex V, Remacle JM, Bonhomme V. World Neurosurg; 2020 Oct; 142():e245-e252. PubMed ID: 32599205 [Abstract] [Full Text] [Related]
11. Subcutaneous Stimulation as an Additional Therapy to Spinal Cord Stimulation for the Treatment of Low Back Pain and Leg Pain in Failed Back Surgery Syndrome: Four-Year Follow-Up. Hamm-Faber TE, Aukes H, van Gorp EJ, Gültuna I. Neuromodulation; 2015 Oct; 18(7):618-22; discussion 622. PubMed ID: 25943093 [Abstract] [Full Text] [Related]
15. Paddle versus cylindrical leads for percutaneous implantation in spinal cord stimulation for failed back surgery syndrome: a single-center trial. Kinfe TM, Quack F, Wille C, Schu S, Vesper J. J Neurol Surg A Cent Eur Neurosurg; 2014 Nov; 75(6):467-73. PubMed ID: 24793061 [Abstract] [Full Text] [Related]
16. "MAST" prospective study: value of minimal access spine technologies technique for multicolumn spinal cord stimulation surgical lead implantation in the context of a French multicentre randomized controlled trial (ESTIMET study). Monlezun O, Voirin J, Roulaud M, Ingrand P, Veyrieras C, Brandet C, Bataille B, Guetarni F, Prévost A, Rigoard P, ESTIMET Group. Neurochirurgie; 2015 Mar; 61 Suppl 1():S125-30. PubMed ID: 25224961 [Abstract] [Full Text] [Related]
17. Comparison of conventional, burst and high-frequency spinal cord stimulation on pain relief in refractory failed back surgery syndrome patients: study protocol for a prospective randomized double-blinded cross-over trial (MULTIWAVE study). Billot M, Naiditch N, Brandet C, Lorgeoux B, Baron S, Ounajim A, Roulaud M, Roy-Moreau A, de Montgazon G, Charrier E, Misbert L, Maillard B, Vendeuvre T, Rigoard P. Trials; 2020 Aug 03; 21(1):696. PubMed ID: 32746899 [Abstract] [Full Text] [Related]