These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study. Trease C, McIff T, Toby EB. J Hand Surg Am; 2005 Jul; 30(4):756-63. PubMed ID: 16039369 [Abstract] [Full Text] [Related]
6. [Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model]. Rudig L, Mehling I, Klitscher D, Mehler D, Prommersberger KJ, Rommens PM, Müller LP. Biomed Tech (Berl); 2009 Jun; 54(3):150-8. PubMed ID: 19469665 [Abstract] [Full Text] [Related]
7. Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: biomechanical comparison with a volar locking plate. Strauss EJ, Banerjee D, Kummer FJ, Tejwani NC. J Trauma; 2008 Apr; 64(4):975-81. PubMed ID: 18404064 [Abstract] [Full Text] [Related]
8. A biomechanical comparison of volar locked plating of intra-articular distal radius fractures: use of 4 versus 7 screws for distal fixation. Moss DP, Means KR, Parks BG, Forthman CL. J Hand Surg Am; 2011 Dec; 36(12):1907-11. PubMed ID: 22018475 [Abstract] [Full Text] [Related]
12. Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression. Marshall T, Momaya A, Eberhardt A, Chaudhari N, Hunt TR. J Hand Surg Am; 2015 Oct; 40(10):2032-8. PubMed ID: 26253601 [Abstract] [Full Text] [Related]
16. Biomechanical analysis of a volar variable-angle locking plate: the effect of capturing a distal radial styloid fragment. Stanbury SJ, Salo A, Elfar JC. J Hand Surg Am; 2012 Dec; 37(12):2488-94. PubMed ID: 23174062 [Abstract] [Full Text] [Related]
17. Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers. Blythe M, Stoffel K, Jarrett P, Kuster M. J Hand Surg Am; 2006 Dec; 31(10):1587-93. PubMed ID: 17145377 [Abstract] [Full Text] [Related]
18. Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study. Mehling I, Müller LP, Delinsky K, Mehler D, Burkhart KJ, Rommens PM. J Hand Surg Am; 2010 Jun; 35(6):885-91. PubMed ID: 20513572 [Abstract] [Full Text] [Related]