These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


169 related items for PubMed ID: 24706432

  • 1. Plasma glucose measurement in diabetes: impact and implications of variations in sample collection procedures with a focus on the first hour after sample collection.
    Chan H, Lunt H, Thompson H, Heenan HF, Frampton CM, Florkowski CM.
    Clin Chem Lab Med; 2014 Jul; 52(7):1061-8. PubMed ID: 24706432
    [Abstract] [Full Text] [Related]

  • 2. Collection tubes containing citrate stabiliser over-estimate plasma glucose, when compared to other samples undergoing immediate plasma separation.
    Carey R, Lunt H, Heenan HF, Frampton CM, Florkowski CM.
    Clin Biochem; 2016 Dec; 49(18):1406-1411. PubMed ID: 27234599
    [Abstract] [Full Text] [Related]

  • 3. Effectiveness of citrate buffer-fluoride mixture in Terumo tubes as an inhibitor of in vitro glycolysis.
    Bonetti G, Carta M, Montagnana M, Lo Cascio C, Bonfigli AR, Mosca A, Testa R, Italian joint SIBioC-SIPMeL Study Group on Diabetes Mellitus.
    Biochem Med (Zagreb); 2016 Dec; 26(1):68-76. PubMed ID: 26981020
    [Abstract] [Full Text] [Related]

  • 4. Glycolysis inhibitors negatively bias blood glucose measurements: potential impact on the reported prevalence of diabetes mellitus.
    Waring WS, Evans LE, Kirkpatrick CT.
    J Clin Pathol; 2007 Jul; 60(7):820-3. PubMed ID: 17596547
    [Abstract] [Full Text] [Related]

  • 5. Which sample tube should be used for routine glucose determination?
    Bonetti G, Cancelli V, Coccoli G, Piccinelli G, Brugnoni D, Caimi L, Carta M.
    Prim Care Diabetes; 2016 Jun; 10(3):227-32. PubMed ID: 26657574
    [Abstract] [Full Text] [Related]

  • 6. Glucose variation in centrifuged serum and lithium-heparin gel tubes stored for up to 96 hours at room temperature or 4 °C.
    Balboni F, Burbui S, Lippi G.
    Scand J Clin Lab Invest; 2018 Jun; 78(7-8):546-550. PubMed ID: 30755098
    [Abstract] [Full Text] [Related]

  • 7. Stability of glucose in plasma with different anticoagulants.
    Fobker M.
    Clin Chem Lab Med; 2014 Jul; 52(7):1057-60. PubMed ID: 24633752
    [Abstract] [Full Text] [Related]

  • 8. Impact of blood cell counts and volumes on glucose concentration in uncentrifuged serum and lithium-heparin blood tubes.
    Lippi G, Salvagno GL, Lampus S, Danese E, Gelati M, Bovo C, Montagnana M, Simundic AM.
    Clin Chem Lab Med; 2018 Nov 27; 56(12):2125-2131. PubMed ID: 29935113
    [Abstract] [Full Text] [Related]

  • 9. Rapid blood separation is superior to fluoride for preventing in vitro reductions in measured blood glucose concentration.
    Shi RZ, Seeley ES, Bowen R, Faix JD.
    J Clin Pathol; 2009 Aug 27; 62(8):752-3. PubMed ID: 19638548
    [Abstract] [Full Text] [Related]

  • 10. Evaluation of BD Vacutainer® Barricor™ blood collection tubes for routine chemistry testing on a Roche Cobas® 8000 Platform.
    Fournier JE, Northrup V, Clark C, Fraser J, Howlett M, Atkinson P, Shea JL.
    Clin Biochem; 2018 Aug 27; 58():94-99. PubMed ID: 29885310
    [Abstract] [Full Text] [Related]

  • 11. Five days serum glucose stability at room-temperature in centrifuged fast-clotting serum tubes and the comparability with glucose in heparin-plasma and plasma containing citrate-stabilizer.
    Bakkebø H, Haaland KL, Hoff KS, Schwettmann L.
    Scand J Clin Lab Invest; 2024 Feb 27; 84(1):62-67. PubMed ID: 38451167
    [Abstract] [Full Text] [Related]

  • 12. Plasma Glucose Concentrations in Different Sampling Tubes Measured on Different Glucose Analysers.
    Pleus S, Beil A, Baumstark A, Haug C, Freckmann G.
    Exp Clin Endocrinol Diabetes; 2024 May 27; 132(5):260-266. PubMed ID: 38307117
    [Abstract] [Full Text] [Related]

  • 13. Evaluation of BD Barricor™ and PST™ blood collection tubes compared to serum for testing 11 therapeutic drugs on a Roche Cobas® 8000 platform.
    Jordan A, Sherazi A, Stevens A, Quondam Franks C, Sturgeon K, Northrup V, Shea JL.
    Clin Biochem; 2022 Feb 27; 100():60-66. PubMed ID: 34788637
    [Abstract] [Full Text] [Related]

  • 14. Liquid citrate acidification introduces significant glucose bias and leads to misclassification of patients with diabetes.
    Juricic G, Kopcinovic LM, Saracevic A, Bakliza A, Simundic AM.
    Clin Chem Lab Med; 2016 Feb 27; 54(2):363-71. PubMed ID: 26136303
    [Abstract] [Full Text] [Related]

  • 15. Citric/citrate buffer: an effective antiglycolytic agent.
    del Pino IG, Constanso I, Mourín LV, Safont CB, Vázquez PR.
    Clin Chem Lab Med; 2013 Oct 27; 51(10):1943-9. PubMed ID: 23612543
    [Abstract] [Full Text] [Related]

  • 16. Comparison of glucose determinations on blood samples collected in three types of tubes.
    Li G, Cabanero M, Wang Z, Wang H, Huang T, Alexis H, Eid I, Muth G, Pincus MR.
    Ann Clin Lab Sci; 2013 Oct 27; 43(3):278-84. PubMed ID: 23884222
    [Abstract] [Full Text] [Related]

  • 17. Glucose is stable during prolonged storage in un-centrifuged Greiner tubes with liquid citrate buffer, but not in serum and NaF/KOx tubes.
    Juricic G, Bakliza A, Saracevic A, Kopcinovic LM, Dobrijevic S, Drmic S, Simundic AM.
    Clin Chem Lab Med; 2016 Mar 27; 54(3):411-8. PubMed ID: 26695197
    [Abstract] [Full Text] [Related]

  • 18. The impact of different sample matrices in delayed measurement of glucose.
    Roccaforte V, Daves M, Platzgummer S, Lippi G.
    Clin Biochem; 2016 Dec 27; 49(18):1412-1415. PubMed ID: 27567939
    [Abstract] [Full Text] [Related]

  • 19. [Effectiveness of sodium fluoride as a glycolysis inhibitor on blood glucose measurement: comparison of blood glucose using specimens from the Korea National Health and Nutrition Examination survey].
    Lee YW, Cha YJ, Chae SL, Song J, Yun YM, Park HI, Seong MW, Whang DH, Kim HS, Kim JH, Lee BS, Hwang YS.
    Korean J Lab Med; 2009 Dec 27; 29(6):524-8. PubMed ID: 20046083
    [Abstract] [Full Text] [Related]

  • 20. Stabilization of Plasma Glucose: The Use of Newer Technology and Pragmatic Laboratory Practice.
    Coward SM, O'Neill FC, McAdam L, Reilly L, McKeeman GC.
    J Appl Lab Med; 2019 May 27; 3(6):1028-1034. PubMed ID: 31639694
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 9.