These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


865 related items for PubMed ID: 24746334

  • 1. Cardiac output measurement by bioimpedance and noninvasive pulse contour analysis compared with the continuous pulmonary artery thermodilution technique.
    Maass SW, Roekaerts PM, Lancé MD.
    J Cardiothorac Vasc Anesth; 2014 Jun; 28(3):534-9. PubMed ID: 24746334
    [Abstract] [Full Text] [Related]

  • 2. Cardiac output determination from endotracheally measured impedance cardiography: clinical evaluation of endotracheal cardiac output monitor.
    Maus TM, Reber B, Banks DA, Berry A, Guerrero E, Manecke GR.
    J Cardiothorac Vasc Anesth; 2011 Oct; 25(5):770-5. PubMed ID: 21354828
    [Abstract] [Full Text] [Related]

  • 3. Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output.
    Bubenek-Turconi SI, Craciun M, Miclea I, Perel A.
    Anesth Analg; 2013 Aug; 117(2):366-72. PubMed ID: 23757471
    [Abstract] [Full Text] [Related]

  • 4. A comparison of endotracheal bioimpedance cardiography and transpulmonary thermodilution in cardiac surgery patients.
    Fellahi JL, Fischer MO, Rebet O, Massetti M, Gérard JL, Hanouz JL.
    J Cardiothorac Vasc Anesth; 2012 Apr; 26(2):217-22. PubMed ID: 21880510
    [Abstract] [Full Text] [Related]

  • 5. The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method.
    Thonnerieux M, Alexander B, Binet C, Obadia JF, Bastien O, Desebbe O.
    Anesth Analg; 2015 Aug; 121(2):383-91. PubMed ID: 25902321
    [Abstract] [Full Text] [Related]

  • 6. Accuracy of noninvasive estimated continuous cardiac output (esCCO) compared to thermodilution cardiac output: a pilot study in cardiac patients.
    Ball TR, Tricinella AP, Kimbrough BA, Luna S, Gloyna DF, Villamaria FJ, Culp WC.
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1128-32. PubMed ID: 23992653
    [Abstract] [Full Text] [Related]

  • 7. Comparison between continuous non-invasive estimated cardiac output by pulse wave transit time and thermodilution method.
    Sinha AC, Singh PM, Grewal N, Aman M, Dubowitz G.
    Ann Card Anaesth; 2014 Dec; 17(4):273-7. PubMed ID: 25281622
    [Abstract] [Full Text] [Related]

  • 8. Lack of agreement and trending ability of the endotracheal cardiac output monitor compared with thermodilution.
    Møller-Sørensen H, Hansen KL, Østergaard M, Andersen LW, Møller K.
    Acta Anaesthesiol Scand; 2012 Apr; 56(4):433-40. PubMed ID: 22191436
    [Abstract] [Full Text] [Related]

  • 9. Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre.
    Cho YJ, Koo CH, Kim TK, Hong DM, Jeon Y.
    J Clin Monit Comput; 2016 Dec; 30(6):771-782. PubMed ID: 26429135
    [Abstract] [Full Text] [Related]

  • 10. Cardiac Output Measurements Based on the Pulse Wave Transit Time and Thoracic Impedance Exhibit Limited Agreement With Thermodilution Method During Orthotopic Liver Transplantation.
    Magliocca A, Rezoagli E, Anderson TA, Burns SM, Ichinose F, Chitilian HV.
    Anesth Analg; 2018 Jan; 126(1):85-92. PubMed ID: 28598912
    [Abstract] [Full Text] [Related]

  • 11. Comparing the Mutual Interchangeability of ECOM, FloTrac/Vigileo, 3D-TEE, and ITD-PAC Cardiac Output Measuring Systems in Coronary Artery Bypass Grafting.
    Milam AJ, Ghoddoussi F, Lucaj J, Narreddy S, Kumar N, Reddy V, Hakim J, Krishnan SH.
    J Cardiothorac Vasc Anesth; 2021 Feb; 35(2):514-529. PubMed ID: 32622708
    [Abstract] [Full Text] [Related]

  • 12. Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output.
    Bein B, Worthmann F, Tonner PH, Paris A, Steinfath M, Hedderich J, Scholz J.
    J Cardiothorac Vasc Anesth; 2004 Apr; 18(2):185-9. PubMed ID: 15073709
    [Abstract] [Full Text] [Related]

  • 13. Cardiac output--pulse contour analysis vs. pulmonary artery thermodilution.
    Ostergaard M, Nielsen J, Rasmussen JP, Berthelsen PG.
    Acta Anaesthesiol Scand; 2006 Oct; 50(9):1044-9. PubMed ID: 16987334
    [Abstract] [Full Text] [Related]

  • 14. [Comparison between continuous and intermittent thermodilution measurement of cardiac output during coronary artery bypass operation].
    Schulz K, Abel HH, Werning P.
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1997 Apr; 32(4):226-33. PubMed ID: 9289022
    [Abstract] [Full Text] [Related]

  • 15. Radial Artery Applanation Tonometry for Continuous Noninvasive Cardiac Output Measurement: A Comparison With Intermittent Pulmonary Artery Thermodilution in Patients After Cardiothoracic Surgery.
    Wagner JY, Sarwari H, Schön G, Kubik M, Kluge S, Reichenspurner H, Reuter DA, Saugel B.
    Crit Care Med; 2015 Jul; 43(7):1423-8. PubMed ID: 25844700
    [Abstract] [Full Text] [Related]

  • 16. Arterial pressure waveform analysis versus thermodilution cardiac output measurement during open abdominal aortic aneurysm repair: a prospective observational study.
    Montenij LJ, Buhre WF, de Jong SA, Harms JH, van Herwaarden JA, Kruitwagen CL, de Waal EE.
    Eur J Anaesthesiol; 2015 Jan; 32(1):13-9. PubMed ID: 25303970
    [Abstract] [Full Text] [Related]

  • 17. Ability of the third-generation FloTrac/Vigileo software to track changes in cardiac output in cardiac surgery patients: a polar plot approach.
    Desebbe O, Henaine R, Keller G, Koffel C, Garcia H, Rosamel P, Obadia JF, Bastien O, Lehot JJ, Haftek M, Critchley LA.
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1122-7. PubMed ID: 24011911
    [Abstract] [Full Text] [Related]

  • 18. Measurements of cardiac output obtained with transesophageal echocardiography and pulmonary artery thermodilution are not interchangeable.
    Møller-Sørensen H, Graeser K, Hansen KL, Zemtsovski M, Sander EM, Nilsson JC.
    Acta Anaesthesiol Scand; 2014 Jan; 58(1):80-8. PubMed ID: 24192143
    [Abstract] [Full Text] [Related]

  • 19. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution.
    Broch O, Bein B, Gruenewald M, Masing S, Huenges K, Haneya A, Steinfath M, Renner J.
    Biomed Res Int; 2016 Jan; 2016():3468015. PubMed ID: 28116294
    [Abstract] [Full Text] [Related]

  • 20. Transesophageal Doppler reliably tracks changes in cardiac output in comparison with intermittent pulmonary artery thermodilution in cardiac surgery patients.
    Møller-Sørensen H, Cordtz J, Østergaard M, Nilsson JC, Hansen KL.
    J Clin Monit Comput; 2017 Feb; 31(1):135-142. PubMed ID: 26578096
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 44.