These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
278 related items for PubMed ID: 24914058
1. Image-derived input function from the vena cava for 18F-FDG PET studies in rats and mice. Lanz B, Poitry-Yamate C, Gruetter R. J Nucl Med; 2014 Aug; 55(8):1380-8. PubMed ID: 24914058 [Abstract] [Full Text] [Related]
2. Impact of Image-Derived Input Function and Fit Time Intervals on Patlak Quantification of Myocardial Glucose Uptake in Mice. Thackeray JT, Bankstahl JP, Bengel FM. J Nucl Med; 2015 Oct; 56(10):1615-21. PubMed ID: 26272811 [Abstract] [Full Text] [Related]
3. Noninvasive image derived heart input function for CMRglc measurements in small animal slow infusion FDG PET studies. Xiong G, Paul C, Todica A, Hacker M, Bartenstein P, Böning G. Phys Med Biol; 2012 Dec 07; 57(23):8041-59. PubMed ID: 23160517 [Abstract] [Full Text] [Related]
5. Image-derived input function in dynamic human PET/CT: methodology and validation with 11C-acetate and 18F-fluorothioheptadecanoic acid in muscle and 18F-fluorodeoxyglucose in brain. Croteau E, Lavallée E, Labbe SM, Hubert L, Pifferi F, Rousseau JA, Cunnane SC, Carpentier AC, Lecomte R, Bénard F. Eur J Nucl Med Mol Imaging; 2010 Aug 07; 37(8):1539-50. PubMed ID: 20437239 [Abstract] [Full Text] [Related]
7. Non-invasive determination of blood input function to compute rate of myocardial glucose uptake from dynamic FDG PET images of rat heart in vivo: comparative study between the inferior vena cava and the left ventricular blood pool with spill over and partial volume corrections. Huang Q, Massey JC, Mińczuk K, Li J, Kundu BK. Phys Med Biol; 2019 Aug 21; 64(16):165010. PubMed ID: 31307015 [Abstract] [Full Text] [Related]
8. Comparison of 3 methods of automated internal carotid segmentation in human brain PET studies: application to the estimation of arterial input function. Zanotti-Fregonara P, Maroy R, Comtat C, Jan S, Gaura V, Bar-Hen A, Ribeiro MJ, Trébossen R. J Nucl Med; 2009 Mar 21; 50(3):461-7. PubMed ID: 19223421 [Abstract] [Full Text] [Related]
10. A curve-fitting approach to estimate the arterial plasma input function for the assessment of glucose metabolic rate and response to treatment. Vriens D, de Geus-Oei LF, Oyen WJ, Visser EP. J Nucl Med; 2009 Dec 21; 50(12):1933-9. PubMed ID: 19910436 [Abstract] [Full Text] [Related]