These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Fast multistation water/fat imaging at 3T using DREAM-based RF shimming. Hooijmans MT, Dzyubachyk O, Nehrke K, Koken P, Versluis MJ, Kan HE, Börnert P. J Magn Reson Imaging; 2015 Jul; 42(1):217-23. PubMed ID: 25331294 [Abstract] [Full Text] [Related]
3. An in vivo comparison of the DREAM sequence with current RF shim technology. Nehrke K, Sprinkart AM, Börnert P. MAGMA; 2015 Apr; 28(2):185-94. PubMed ID: 25108702 [Abstract] [Full Text] [Related]
5. Improvement in B1+ Homogeneity and Average Flip Angle Using Dual-Source Parallel RF Excitation for Cardiac MRI in Swine Hearts. Schär M, Ding H, Herzka DA. PLoS One; 2015 Apr; 10(10):e0139859. PubMed ID: 26436658 [Abstract] [Full Text] [Related]
7. Dual-source radiofrequency transmission with patient-adaptive local radiofrequency shimming for 3.0-T cardiac MR imaging: initial experience. Mueller A, Kouwenhoven M, Naehle CP, Gieseke J, Strach K, Willinek WA, Schild HH, Thomas D. Radiology; 2012 Apr; 263(1):77-85. PubMed ID: 22371610 [Abstract] [Full Text] [Related]
8. Liver: segment-specific analysis of B1 field homogeneity at 3.0-T MR imaging with single-source versus dual-source parallel radiofrequency excitation. Pazahr S, Fischer MA, Chuck N, Luechinger R, Schick F, Nanz D, Boss A. Radiology; 2012 Nov; 265(2):591-9. PubMed ID: 22929333 [Abstract] [Full Text] [Related]
9. B1 homogeneity of breast MRI using RF shimming with individual specific values in volunteers simulating patients after mastectomy. Abe T. Acta Radiol; 2016 Nov; 57(11):1289-1296. PubMed ID: 25995312 [Abstract] [Full Text] [Related]
10. B1 artifact reduction in abdominal DCE-MRI using kT -points: First clinical assessment of dynamic RF shimming at 3T. Tomi-Tricot R, Gras V, Mauconduit F, Legou F, Boulant N, Gebhardt M, Ritter D, Kiefer B, Zerbib P, Rahmouni A, Vignaud A, Luciani A, Amadon A. J Magn Reson Imaging; 2018 Jun; 47(6):1562-1571. PubMed ID: 29159855 [Abstract] [Full Text] [Related]
11. Evaluation of dual-source parallel RF excitation for diffusion-weighted whole-body MR imaging with background body signal suppression at 3.0 T. Mürtz P, Kaschner M, Träber F, Kukuk GM, Büdenbender SM, Skowasch D, Gieseke J, Schild HH, Willinek WA. Eur J Radiol; 2012 Nov; 81(11):3614-23. PubMed ID: 22178311 [Abstract] [Full Text] [Related]
13. High-dose dobutamine stress steady-state free precession (SSFP) cine MRI at 3T with patient adaptive local radiofrequency (RF) shimming using dual-source RF transmission. Berger A, Schnackenburg B, Schneeweis C, Kelle S, Klein C, Kouwenhoven M, Fleck E, Gebker R. J Magn Reson Imaging; 2015 Sep; 42(3):746-53. PubMed ID: 25683284 [Abstract] [Full Text] [Related]