These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


356 related items for PubMed ID: 24954572

  • 21. "Valve in valve" implantation of two self-expandable transcatheter aortic valves in a patient with aortic root aneurysm and massive aortic regurgitation: "a new TAVI option".
    Pesarini G, Bedogni F, Ribichini F.
    Catheter Cardiovasc Interv; 2014 Apr 01; 83(5):836-40. PubMed ID: 24038951
    [Abstract] [Full Text] [Related]

  • 22. Aortic valve/root procedures in patients with an anomalous left circumflex coronary artery and a bicuspid aortic valve: anatomical and technical implications.
    Liebrich M, Tzanavaros I, Scheid M, Voth W, Doll KN, Hemmer WB.
    Interact Cardiovasc Thorac Surg; 2015 Jul 01; 21(1):114-6. PubMed ID: 25820760
    [Abstract] [Full Text] [Related]

  • 23. Severe valve deformation following cardiopulmonary resuscitation in a patient with a transcatheter aortic valve.
    Don CW, McCabe JM, Fligner CL.
    JACC Cardiovasc Interv; 2015 Mar 01; 8(3):498-499. PubMed ID: 25790765
    [No Abstract] [Full Text] [Related]

  • 24. Bicuspid aortic valve and associated aortopathy: an update.
    Girdauskas E, Borger MA.
    Semin Thorac Cardiovasc Surg; 2013 Mar 01; 25(4):310-6. PubMed ID: 24673960
    [Abstract] [Full Text] [Related]

  • 25. How should I treat a left ventricular outflow tract-migrated balloon-expandable transcatheter heart valve?
    Barbash IM, Bogdan A, Fefer P, Spiegelstein D, Raanani E, Beinart R, Guetta V, Segev A, Eggebrecht H, Zierer A, Dworakowski R, MacCarthy P.
    EuroIntervention; 2016 Mar 01; 11(12):1442-5. PubMed ID: 26999684
    [No Abstract] [Full Text] [Related]

  • 26. Elliptical shape of a SAPIEN XT prosthesis deployed in a patient with bicuspid aortic valve stenosis.
    Zegdi R, Blanchard D, Azarine A, Folliguet T, Fabiani JN.
    J Heart Valve Dis; 2012 Nov 01; 21(6):764-6. PubMed ID: 23409359
    [Abstract] [Full Text] [Related]

  • 27.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 28. [Aneurysmatic aortic root in bicuspid aortic valve stenosis: mini-invasive approach with sutureless prosthesis].
    Pollari F, Santarpino G, Pfeiffer S, Fischlein T.
    Monaldi Arch Chest Dis; 2014 Jun 01; 82(2):112-4. PubMed ID: 25845096
    [Abstract] [Full Text] [Related]

  • 29. Transfemoral transcatheter valve-in-valve-in-valve replacement.
    Leung Wai Sang S, Giri J, Vallabhajosyula P.
    J Thorac Cardiovasc Surg; 2016 Aug 01; 152(2):622-3. PubMed ID: 27179844
    [No Abstract] [Full Text] [Related]

  • 30. Anterior Mitral Leaflet Perforation During Transcatheter Aortic Valve Replacement in a Patient With Mitral Annular Calcification.
    Saji M, Ailawadi G, Ragosta M, Fowler DE, Dent JM, Lim DS.
    JACC Cardiovasc Interv; 2015 Nov 01; 8(13):e215-6. PubMed ID: 26476607
    [No Abstract] [Full Text] [Related]

  • 31. Implications of bicuspid aortic valves for transcatheter aortic valve implantation.
    O'Sullivan CJ, Windecker S.
    Circ Cardiovasc Interv; 2013 Jun 01; 6(3):204-6. PubMed ID: 23780294
    [No Abstract] [Full Text] [Related]

  • 32. Persistent native aortic valve function after transcatheter aortic valve replacement.
    Singh V, Martinez CA, O'Neill WW, Heldman AW.
    Tex Heart Inst J; 2013 Jun 01; 40(3):364-6. PubMed ID: 23914043
    [Abstract] [Full Text] [Related]

  • 33. Clinical outcomes of the Lotus Valve in patients with bicuspid aortic valve stenosis: An analysis from the RESPOND study.
    Blackman DJ, Van Gils L, Bleiziffer S, Gerckens U, Petronio AS, Abdel-Wahab M, Werner N, Khogali SS, Wenaweser P, Wöhrle J, Soliman O, Laborde JC, Allocco DJ, Meredith IT, Falk V, Van Mieghem NM.
    Catheter Cardiovasc Interv; 2019 May 01; 93(6):1116-1123. PubMed ID: 30773838
    [Abstract] [Full Text] [Related]

  • 34.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 35. Transcarotid aortic valve-in-valve implantation for degenerated stentless aortic root conduits with severe regurgitation: a case series.
    Huber C, Praz F, O'Sullivan CJ, Langhammer B, Gloekler S, Stortecky S, von Allmen RS, Meier B, Carrel T, Englberger L, Windecker S, Wenaweser P.
    Interact Cardiovasc Thorac Surg; 2015 Jun 01; 20(6):694-700. PubMed ID: 25776924
    [Abstract] [Full Text] [Related]

  • 36.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 37. Transcatheter aortic valve implantation in patients with bicuspid aortic valve stenosis.
    Wijesinghe N, Ye J, Rodés-Cabau J, Cheung A, Velianou JL, Natarajan MK, Dumont E, Nietlispach F, Gurvitch R, Wood DA, Tay E, Webb JG.
    JACC Cardiovasc Interv; 2010 Nov 01; 3(11):1122-5. PubMed ID: 21087746
    [Abstract] [Full Text] [Related]

  • 38. Defying Dogma: Recovery After Left Ventricular Assist Device Implantation and Aortic Valve Replacement for Bicuspid Aortic Valve.
    Sperry BW, Jacob MS, Menon V, Soltesz EG, Rodriguez ER, Popović ZB.
    Circ Heart Fail; 2015 Jul 01; 8(4):832-5. PubMed ID: 26199310
    [No Abstract] [Full Text] [Related]

  • 39. Transcatheter aortic valve implantation through the left subclavian artery with a patent LIMA graft.
    Taramasso M, Giacomini A, Maisano F.
    Catheter Cardiovasc Interv; 2010 Jul 01; 76(1):153-5. PubMed ID: 20578101
    [Abstract] [Full Text] [Related]

  • 40. Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis Using Lotus Valve System.
    Chan AW, Wong D, Charania J.
    Catheter Cardiovasc Interv; 2017 Jul 01; 90(1):157-163. PubMed ID: 27029503
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 18.