These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Glucose is stable during prolonged storage in un-centrifuged Greiner tubes with liquid citrate buffer, but not in serum and NaF/KOx tubes. Juricic G, Bakliza A, Saracevic A, Kopcinovic LM, Dobrijevic S, Drmic S, Simundic AM. Clin Chem Lab Med; 2016 Mar; 54(3):411-8. PubMed ID: 26695197 [Abstract] [Full Text] [Related]
5. Effectiveness of citrate buffer-fluoride mixture in Terumo tubes as an inhibitor of in vitro glycolysis. Bonetti G, Carta M, Montagnana M, Lo Cascio C, Bonfigli AR, Mosca A, Testa R, Italian joint SIBioC-SIPMeL Study Group on Diabetes Mellitus. Biochem Med (Zagreb); 2016 Mar; 26(1):68-76. PubMed ID: 26981020 [Abstract] [Full Text] [Related]
6. Various glycolysis inhibitor-containing tubes for glucose measurement cannot be used interchangeably due to clinically unacceptable biases between them. Saracevic A, Dukic L, Juricic G, Milevoj Kopcinovic L, Mirosevic G, Simundic AM. Clin Chem Lab Med; 2018 Jan 26; 56(2):236-241. PubMed ID: 28746044 [Abstract] [Full Text] [Related]
7. Rapid blood separation is superior to fluoride for preventing in vitro reductions in measured blood glucose concentration. Shi RZ, Seeley ES, Bowen R, Faix JD. J Clin Pathol; 2009 Aug 26; 62(8):752-3. PubMed ID: 19638548 [Abstract] [Full Text] [Related]
8. Citric/citrate buffer: an effective antiglycolytic agent. del Pino IG, Constanso I, Mourín LV, Safont CB, Vázquez PR. Clin Chem Lab Med; 2013 Oct 26; 51(10):1943-9. PubMed ID: 23612543 [Abstract] [Full Text] [Related]
9. Which sample tube should be used for routine glucose determination? Bonetti G, Cancelli V, Coccoli G, Piccinelli G, Brugnoni D, Caimi L, Carta M. Prim Care Diabetes; 2016 Jun 26; 10(3):227-32. PubMed ID: 26657574 [Abstract] [Full Text] [Related]
10. Five days serum glucose stability at room-temperature in centrifuged fast-clotting serum tubes and the comparability with glucose in heparin-plasma and plasma containing citrate-stabilizer. Bakkebø H, Haaland KL, Hoff KS, Schwettmann L. Scand J Clin Lab Invest; 2024 Feb 26; 84(1):62-67. PubMed ID: 38451167 [Abstract] [Full Text] [Related]
11. Acid freezes uricolysis in addition to glycolysis: Utility of fluoride-EDTA-citrate tube in the measurement of uric acid for patients administered rasburicase. Kalaria T, Fenn J, Whitmill R, Ford C, Gama R. Ann Clin Biochem; 2022 May 26; 59(3):178-182. PubMed ID: 34989247 [Abstract] [Full Text] [Related]
12. Glycolysis inhibitors negatively bias blood glucose measurements: potential impact on the reported prevalence of diabetes mellitus. Waring WS, Evans LE, Kirkpatrick CT. J Clin Pathol; 2007 Jul 26; 60(7):820-3. PubMed ID: 17596547 [Abstract] [Full Text] [Related]
13. Glucose sampling: importance of citrate. Carta M, Montagnana M, Cascio CL, Bonetti G, Italian joint SIBioC-SIPMeL study group on diabetes mellitus. Ann Clin Biochem; 2016 Nov 26; 53(6):715-716. PubMed ID: 27151959 [No Abstract] [Full Text] [Related]
14. Technical and clinical validation of the Greiner FC-Mix glycaemia tube. van der Hagen EAE, Fokkert MJ, Kleefman AMD, Thelen MHM, van den Berg SAA, Slingerland RJ. Clin Chem Lab Med; 2017 Aug 28; 55(10):1530-1536. PubMed ID: 28284032 [Abstract] [Full Text] [Related]
16. Use of different anticoagulants in test tubes for analysis of blood lactate concentrations: Part 2. Implications for the proper handling of blood specimens obtained from critically ill patients. Wiese J, Didwania A, Kerzner R, Chernow B. Crit Care Med; 1997 Nov 28; 25(11):1847-50. PubMed ID: 9366768 [Abstract] [Full Text] [Related]
17. Effect of Collection Tube Type on Glucose Stability in Whole Blood. Jung J, Garnett E, Rector K, Jariwala P, Devaraj S. Ann Clin Lab Sci; 2020 Jul 28; 50(4):557-559. PubMed ID: 32826256 [Abstract] [Full Text] [Related]
18. Comparison of glucose determinations on blood samples collected in three types of tubes. Li G, Cabanero M, Wang Z, Wang H, Huang T, Alexis H, Eid I, Muth G, Pincus MR. Ann Clin Lab Sci; 2013 Jul 28; 43(3):278-84. PubMed ID: 23884222 [Abstract] [Full Text] [Related]
19. Collection tubes containing citrate stabiliser over-estimate plasma glucose, when compared to other samples undergoing immediate plasma separation. Carey R, Lunt H, Heenan HF, Frampton CM, Florkowski CM. Clin Biochem; 2016 Dec 28; 49(18):1406-1411. PubMed ID: 27234599 [Abstract] [Full Text] [Related]
20. [Effectiveness of sodium fluoride as a glycolysis inhibitor on blood glucose measurement: comparison of blood glucose using specimens from the Korea National Health and Nutrition Examination survey]. Lee YW, Cha YJ, Chae SL, Song J, Yun YM, Park HI, Seong MW, Whang DH, Kim HS, Kim JH, Lee BS, Hwang YS. Korean J Lab Med; 2009 Dec 28; 29(6):524-8. PubMed ID: 20046083 [Abstract] [Full Text] [Related] Page: [Next] [New Search]