These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
238 related items for PubMed ID: 25211625
1. Correction of the slope-intercept method for the measurement of glomerular filtration rate. Blake GM, Barnfield MC, Burniston MT, Fleming JS, Cosgriff PS, Siddique M. Nucl Med Commun; 2014 Dec; 35(12):1277-83. PubMed ID: 25211625 [Abstract] [Full Text] [Related]
4. Age-specific normal reference ranges for 99mTc-DTPA glomerular filtration rate to use with two-sample slope-intercept method and Jodal Brochner-Mortensen correction. Gautam S. Phys Eng Sci Med; 2021 Dec; 44(4):1331-1340. PubMed ID: 34694586 [Abstract] [Full Text] [Related]
5. Simplified methods for assessment of renal function as the ratio of glomerular filtration rate to extracellular fluid volume. Jødal L, Brøchner-Mortensen J. Nucl Med Commun; 2012 Dec; 33(12):1243-53. PubMed ID: 23111354 [Abstract] [Full Text] [Related]
6. Correction of slope-intercept glomerular filtration rate measurement without scaling for body size. McMeekin H, Burniston MT, Barnfield M, Peters AM. Nucl Med Commun; 2021 Jan; 42(1):68-72. PubMed ID: 33165257 [Abstract] [Full Text] [Related]
7. Measuring glomerular filtration rate using 51Cr-EDTA: body surface area normalization before or after Bröchner-Mortensen correction? Pottel H, Hoste L, De Waele L, Braat E, Baete K, Goffin K, Levtchenko E, Gheysens O. Nucl Med Commun; 2014 Nov; 35(11):1150-5. PubMed ID: 25144564 [Abstract] [Full Text] [Related]
8. (99m)Tc-DTPA volume of distribution, half-life and glomerular filtration rate in normal adults. Holness JL, Fleming JS, Malaroda AL, Warwick JM. Nucl Med Commun; 2013 Oct; 34(10):1005-14. PubMed ID: 23880899 [Abstract] [Full Text] [Related]
9. Comparison between terminal slope rate constant and "slope/intercept" as measures of glomerular filtration rate using the single-compartment simplification. Peters AM, Henderson BL, Lui D. Eur J Nucl Med; 2001 Mar; 28(3):320-6. PubMed ID: 11315599 [Abstract] [Full Text] [Related]
10. An improved equation for correcting slope-intercept measurements of glomerular filtration rate for the single exponential approximation. Fleming JS. Nucl Med Commun; 2007 Apr; 28(4):315-20. PubMed ID: 17325596 [Abstract] [Full Text] [Related]
11. Reassessment of a classical single injection 51Cr-EDTA clearance method for determination of renal function in children and adults. Part II: Empirically determined relationships between total and one-pool clearance. Brøchner-Mortensen J, Jødal L. Scand J Clin Lab Invest; 2009 Apr; 69(3):314-22. PubMed ID: 19191067 [Abstract] [Full Text] [Related]
12. The single-plasma-sample method for determining the glomerular filtration rate with Tc-99m-diethylenetriamine pentaacetic acid in childhood and adolescence: is it age-dependent? Itoh K, Matsuyama T. Ann Nucl Med; 2002 Dec; 16(8):541-8. PubMed ID: 12593419 [Abstract] [Full Text] [Related]
13. Indexed glomerular filtration rate as a function of age and body size. Peters AM, Henderson BL, Lui D. Clin Sci (Lond); 2000 Apr; 98(4):439-44. PubMed ID: 10731478 [Abstract] [Full Text] [Related]
14. Chromium-51-EDTA clearance in adults with a single-plasma sample. Mårtensson J, Groth S, Rehling M, Gref M. J Nucl Med; 1998 Dec; 39(12):2131-7. PubMed ID: 9867156 [Abstract] [Full Text] [Related]
15. Iohexol plasma clearance in children: validation of multiple formulas and two-point sampling times. Tøndel C, Bolann B, Salvador CL, Brackman D, Bjerre A, Svarstad E, Brun A. Pediatr Nephrol; 2017 Feb; 32(2):311-320. PubMed ID: 27369694 [Abstract] [Full Text] [Related]
16. Accuracy of plasma sample methods for determination of glomerular filtration rate with 99mTc-DTPA. Itoh K, Tsushima S, Tsukamoto E, Tamaki N. Ann Nucl Med; 2002 Feb; 16(1):39-44. PubMed ID: 11922207 [Abstract] [Full Text] [Related]
17. Validation of Glomerular Filtration Rate Measurement with Blood Sampling from the Injection Site. Mekonnen BW, Warwick JM, Holness JL. J Nucl Med Technol; 2019 Dec; 47(4):305-308. PubMed ID: 31182668 [Abstract] [Full Text] [Related]
18. Glomerular filtration rate estimation by use of a correction formula for slope-intercept plasma iohexol clearance in cats. Finch NC, Syme HM, Elliott J, Peters AM, Gerritsen R, Croubels S, Heiene R. Am J Vet Res; 2011 Dec; 72(12):1652-9. PubMed ID: 22126694 [Abstract] [Full Text] [Related]
19. Determination of Glomerular Filtration Rate with CT Measurement of Renal Clearance of Iodinated Contrast Material versus 99mTc-DTPA Dynamic Imaging "Gates" Method: A Validation Study in Asymmetrical Renal Disease. Yuan X, Zhang J, Tang K, Quan C, Tian Y, Li H, Ao G, Qiu L. Radiology; 2017 Feb; 282(2):552-560. PubMed ID: 27556274 [Abstract] [Full Text] [Related]
20. Reassessment of a classical single injection 51Cr-EDTA clearance method for determination of renal function in children and adults. Part I: Analytically correct relationship between total and one-pool clearance. Jødal L, Brøchner-Mortensen J. Scand J Clin Lab Invest; 2009 Feb; 69(3):305-13. PubMed ID: 19048437 [Abstract] [Full Text] [Related] Page: [Next] [New Search]