These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


115 related items for PubMed ID: 25280640

  • 1. Use of gel-based separator tubes to stabilise phosphate in mailed blood samples.
    Herrington W, Clark S, Staplin N, Kumar A, Illingworth N, Sutherland S, Baigent C, Landray M, Haynes R, Hill M.
    Clin Chim Acta; 2015 Jan 15; 439():112-4. PubMed ID: 25280640
    [No Abstract] [Full Text] [Related]

  • 2. A comparison of stability of chemical analytes in plasma from the BD Vacutainer® Barricor™ tube with mechanical separator versus tubes containing gel separator.
    Gawria G, Tillmar L, Landberg E.
    J Clin Lab Anal; 2020 Feb 15; 34(2):e23060. PubMed ID: 31605419
    [Abstract] [Full Text] [Related]

  • 3. Reliability of serum separator blood drawing tubes under routine conditions.
    Eichhorn U, Helwig-Rolig A, Kirchner G, Kropf J, Gressner AM.
    Eur J Clin Chem Clin Biochem; 1997 Jun 15; 35(6):483-4. PubMed ID: 9228333
    [No Abstract] [Full Text] [Related]

  • 4. Solution densities and estimated total protein contents associated with inappropriate flotation of separator gel in different blood collection tubes.
    Faught RC, Marshall J, Bornhorst J.
    Arch Pathol Lab Med; 2011 Sep 15; 135(9):1081-4. PubMed ID: 21877989
    [Abstract] [Full Text] [Related]

  • 5. Stability of digoxin and digitoxin in specimens collected in blood collection tubes containing serum separator gels.
    Datta P.
    Clin Biochem; 1998 Jun 15; 31(4):273-5. PubMed ID: 9646952
    [No Abstract] [Full Text] [Related]

  • 6. High total protein impairs appropriate gel barrier formation in BD Vacutainer blood collection tubes.
    van den Ouweland JM, Church S.
    Clin Chem; 2007 Feb 15; 53(2):364-5. PubMed ID: 17259253
    [No Abstract] [Full Text] [Related]

  • 7. [Correct handling of serum separating gel tubes is of significance].
    Daae LN, Juell A, Lund PK.
    Tidsskr Nor Laegeforen; 1989 Feb 20; 109(5):599-601. PubMed ID: 2922723
    [Abstract] [Full Text] [Related]

  • 8. Absorption of therapeutic drugs by barrier gels in serum separator blood collection tubes. Volume- and time-dependent reduction in total and free drug concentrations.
    Dasgupta A, Dean R, Saldana S, Kinnaman G, McLawhon RW.
    Am J Clin Pathol; 1994 Apr 20; 101(4):456-61. PubMed ID: 8160636
    [Abstract] [Full Text] [Related]

  • 9. Elevated results in a vitamin B12 assay when using serum separator blood collection tubes.
    Lowrey I, Smith G.
    Ann Clin Biochem; 2003 Sep 20; 40(Pt 5):560-2. PubMed ID: 14503995
    [Abstract] [Full Text] [Related]

  • 10. Evaluation of serum separator tubes as a mail transport device in primary health care.
    Sandberg S, Christensen NG, Horgen E, Jacobsen H, Johansen K.
    Scand J Prim Health Care; 1988 Nov 20; 6(4):251-4. PubMed ID: 3231943
    [Abstract] [Full Text] [Related]

  • 11. Stability of therapeutic drug measurement in specimens collected in VACUTAINER plastic blood-collection tubes.
    Dasgupta A, Blackwell W, Bard D.
    Ther Drug Monit; 1996 Jun 20; 18(3):306-9. PubMed ID: 8738774
    [Abstract] [Full Text] [Related]

  • 12. Chlamydia trachomatis antibody detection in home-collected blood samples for use in epidemiological studies.
    Hoenderboom BM, van Ess EF, van den Broek IVF, van Loo IHM, Hoebe CJPA, Ouburg S, Morré SA.
    J Microbiol Methods; 2018 Jan 20; 144():164-167. PubMed ID: 29196272
    [Abstract] [Full Text] [Related]

  • 13. Pseudonormokalaemia caused by recentrifugation of blood samples after storage in gel-separator tubes.
    Hira K, Aoki N, Fukui T.
    Ann Clin Biochem; 2004 Jan 20; 41(Pt 1):82. PubMed ID: 14713392
    [No Abstract] [Full Text] [Related]

  • 14. Measurement of organochlorine levels in postprandial serum or in blood collected in serum separator tubes.
    Longnecker MP, Bernstein L, Bird CL, Yancey AK, Peterson JC.
    Cancer Epidemiol Biomarkers Prev; 1996 Sep 20; 5(9):753-5. PubMed ID: 8877068
    [Abstract] [Full Text] [Related]

  • 15. Performance of evacuated blood collection tubes at high altitude.
    MacNutt MJ, Sheel AW.
    High Alt Med Biol; 2008 Sep 20; 9(3):235-7. PubMed ID: 18800961
    [Abstract] [Full Text] [Related]

  • 16. Abnormal gel flotation in a patient with apperant pneumonia diagnosis: a case report.
    Gerin F, Ramazan DC, Baykan O, Sirikci O, Haklar G.
    Biochem Med (Zagreb); 2014 Sep 20; 24(1):180-2. PubMed ID: 24627728
    [Abstract] [Full Text] [Related]

  • 17. What´s floating on my plasma?
    Cadamuro J, Wiedemann H, Felder TK, Mrazek C, Kipman U, Hannes O, Haschke-Becher E.
    Biochem Med (Zagreb); 2017 Jun 15; 27(2):430-433. PubMed ID: 28694735
    [Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19. Different collection tubes in cardiac biomarkers detection.
    Daves M, Trevisan D, Cemin R.
    J Clin Lab Anal; 2008 Jun 15; 22(6):391-4. PubMed ID: 19021266
    [Abstract] [Full Text] [Related]

  • 20.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 6.