These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
101 related items for PubMed ID: 25465654
1. Three week loading for the Baha BI-300® implant system. Wazen JJ, Daugherty J, Darley S, Wycherly B. Am J Otolaryngol; 2015; 36(2):195-9. PubMed ID: 25465654 [Abstract] [Full Text] [Related]
2. The role of stability measurements of the Baha® system in children. Felton M, Hill-Feltham P, Bruce IA. Int J Pediatr Otorhinolaryngol; 2014 Mar; 78(3):513-6. PubMed ID: 24467920 [Abstract] [Full Text] [Related]
3. Osseointegration timing for Baha system loading. Wazen JJ, Gupta R, Ghossaini S, Spitzer J, Farrugia M, Tjellstrom A. Laryngoscope; 2007 May; 117(5):794-6. PubMed ID: 17473670 [Abstract] [Full Text] [Related]
4. Three-week loading of the 4.5mm wide titanium implant in bone anchored hearing systems. Wazen JJ, Babu S, Daugherty J, Metrailer A. Am J Otolaryngol; 2016 May; 37(2):132-5. PubMed ID: 26954868 [Abstract] [Full Text] [Related]
5. Resonance frequency analysis of osseo-integrated implants for bone conduction in a pediatric population - a novel approach for assessing stability for early loading. McLarnon C, Johnson I, Davison T, Hill J, Henderson B, Leese D, Marley S. Int J Pediatr Otorhinolaryngol; 2014 Apr; 78(4):641-4. PubMed ID: 24518815 [Abstract] [Full Text] [Related]
6. Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerability. Nelissen RC, den Besten CA, Faber HT, Dun CA, Mylanus EA, Hol MK. Eur Arch Otorhinolaryngol; 2016 Jul; 273(7):1731-7. PubMed ID: 26272679 [Abstract] [Full Text] [Related]
7. Evidence for early loading of osseointegrated implants for bone conduction at 4 weeks. McLarnon CM, Johnson I, Davison T, Hill J, Henderson B, Leese D, Marley S. Otol Neurotol; 2012 Dec; 33(9):1578-82. PubMed ID: 23069746 [Abstract] [Full Text] [Related]
8. The new Baha implant: a prospective osseointegration study. D'Eredità R, Caroncini M, Saetti R. Otolaryngol Head Neck Surg; 2012 Jun; 146(6):979-83. PubMed ID: 22344291 [Abstract] [Full Text] [Related]
9. Assessment of more than 1,000 implanted percutaneous bone conduction devices: skin reactions and implant survival. Dun CA, Faber HT, de Wolf MJ, Mylanus EA, Cremers CW, Hol MK. Otol Neurotol; 2012 Feb; 33(2):192-8. PubMed ID: 22246385 [Abstract] [Full Text] [Related]
11. The Cochlear Baha 4 Attract System - design concepts, surgical technique and early clinical results. Clamp PJ, Briggs RJ. Expert Rev Med Devices; 2015 May; 12(3):223-30. PubMed ID: 25496651 [Abstract] [Full Text] [Related]
12. Stability, survival, and tolerability of a novel baha implant system: six-month data from a multicenter clinical investigation. Dun CA, de Wolf MJ, Hol MK, Wigren S, Eeg-Olofsson M, Green K, Karlsmo A, Flynn MC, Stalfors J, Rothera M, Mylanus EA, Cremers CW. Otol Neurotol; 2011 Aug; 32(6):1001-7. PubMed ID: 21725257 [Abstract] [Full Text] [Related]
13. Osseointegrated hearing implant surgery using a novel hydroxyapatite-coated concave abutment design. Wilkie MD, Chakravarthy KM, Mamais C, Temple RH. Otolaryngol Head Neck Surg; 2014 Dec; 151(6):1014-9. PubMed ID: 25245135 [Abstract] [Full Text] [Related]
14. Stability of osseointegrated bone conduction systems in children: a pilot study. Marsella P, Scorpecci A, D'Eredità R, Della Volpe A, Malerba P. Otol Neurotol; 2012 Jul; 33(5):797-803. PubMed ID: 22643446 [Abstract] [Full Text] [Related]
15. Bone-anchored hearing implant loading at 3 weeks: stability and tolerability after 6 months. Faber HT, Dun CA, Nelissen RC, Mylanus EA, Cremers CW, Hol MK. Otol Neurotol; 2013 Jan; 34(1):104-10. PubMed ID: 23202148 [Abstract] [Full Text] [Related]
16. Exploring factors that affect the age of cochlear implantation in children. Fitzpatrick EM, Johnson E, Durieux-Smith A. Int J Pediatr Otorhinolaryngol; 2011 Sep; 75(9):1082-7. PubMed ID: 21703694 [Abstract] [Full Text] [Related]
17. The BAHA hearing system for hearing-impaired postirradiated nasopharyngeal cancer patients: a new indication. Soo G, Tong MC, Tsang WS, Wong TK, To KF, Leung SF, van Hasselt CA. Otol Neurotol; 2009 Jun; 30(4):496-501. PubMed ID: 19415040 [Abstract] [Full Text] [Related]
18. Cochlear implantation in patients with substantial residual hearing. Cullen RD, Higgins C, Buss E, Clark M, Pillsbury HC, Buchman CA. Laryngoscope; 2004 Dec; 114(12):2218-23. PubMed ID: 15564849 [Abstract] [Full Text] [Related]
19. Evaluation of Bone Conduction Implant Stability and Soft Tissue Status in Children in Relation to Age, Bone Thickness, and Sound Processor Loading Time. Mierzwiński J, Konopka W, Drela M, Łaz P, Śmiechura M, Strużycka M, Kuśmierczyk J. Otol Neurotol; 2015 Aug; 36(7):1209-15. PubMed ID: 25569363 [Abstract] [Full Text] [Related]
20. Stability, marginal bone loss and survival of standard and modified sand-blasted, acid-etched implants in bilateral edentulous spaces: a prospective 15-month evaluation. Karabuda ZC, Abdel-Haq J, Arisan V. Clin Oral Implants Res; 2011 Aug; 22(8):840-9. PubMed ID: 21198901 [Abstract] [Full Text] [Related] Page: [Next] [New Search]