These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
159 related items for PubMed ID: 25468361
1. Unexpected triggering of the dialysate blood leak detector by haemolysis. Lindley E, Finney D, Jones P, Lewington A, O'Reagan A, Webb G. Acta Clin Belg; 2015 Jun; 70(3):226-9. PubMed ID: 25468361 [Abstract] [Full Text] [Related]
4. Pseudo-blood leak? A hemodialysis mystery. Avila J, Prasad D, Weisberg LS, Kasama R. Clin Nephrol; 2013 Apr; 79(4):323-5. PubMed ID: 23537683 [Abstract] [Full Text] [Related]
5. [Acute hemolysis with subsequent life-threatening pancreatitis in hemodialysis. A complication which is not preventable with current dialysis equipment]. Daul AE, Schäfers RF, Wenzel RR, Loew H, Windeck R, Philipp T. Dtsch Med Wochenschr; 1994 Sep 23; 119(38):1263-9. PubMed ID: 7924917 [Abstract] [Full Text] [Related]
6. Blood leak alarm interference by hydoxocobalamin is hemodialysis machine dependent. Sutter ME, Clarke ME, Cobb J, Daubert GP, Rathore VS, Aston LS, Poppenga RH, Ford JB, Owen KP, Albertson TE. Clin Toxicol (Phila); 2012 Dec 23; 50(10):892-5. PubMed ID: 23148566 [Abstract] [Full Text] [Related]
7. Blood trauma in plastic haemodialysis cannulae. De Wachter DS, Verdonck PR, De Vos JY, Hombrouckx RO. Int J Artif Organs; 1997 Jul 23; 20(7):366-70. PubMed ID: 9298407 [Abstract] [Full Text] [Related]
8. In Vitro Comparative Assessment of Mechanical Blood Damage Induced by Different Hemodialysis Treatments. Sakota R, Lodi CA, Sconziano SA, Beck W, Bosch JP. Artif Organs; 2015 Dec 23; 39(12):1015-23. PubMed ID: 25981394 [Abstract] [Full Text] [Related]
9. [Efficiency of dialysis with albumin in the treatment of patients with advanced hepatic insufficiency: initial experience with the MARS system in Spain]. Avilés J, Macía M, Morales S, Pérez F, Moreno A, Navarro J, Navazo L, García J. Nefrologia; 2001 Dec 23; 21(4):376-85. PubMed ID: 11816514 [Abstract] [Full Text] [Related]
10. Hemolysis as Cause of Hemodialysis Blood Leak Alarm: Case Study of a Patient with Freshwater Near-Drowning. Jepson R, Hartlein M, Hauf LD, Garett-Golden C, Mahoney D, Giullian J. Nephrol Nurs J; 2021 Dec 23; 48(3):237-240. PubMed ID: 34286933 [Abstract] [Full Text] [Related]
11. Efficacy of ultra-pure dialysate in the therapy and prevention of haemodialysis-associated amyloidosis. Lonnemann G, Koch KM. Nephrol Dial Transplant; 2001 Dec 23; 16 Suppl 4():17-22. PubMed ID: 11402092 [No Abstract] [Full Text] [Related]
12. Artificial kidney: status of the art and new perspectives. Stefoni S, Cianciolo G, Colì L, Raimondi C, Dalmastri V, Donati G, Manna C, Grammatico F. Artif Cells Blood Substit Immobil Biotechnol; 2003 May 23; 31(2):111-2. PubMed ID: 12751828 [Abstract] [Full Text] [Related]
15. Machines for hemodialysis. Polaschegg HD. Contrib Nephrol; 2005 May 23; 149():18-26. PubMed ID: 15876824 [Abstract] [Full Text] [Related]
16. Abdominal emergency in a dialysis patient: haemolysis from kinking of dialysis tubing. Rambausek M, Wallmeier K, Schwarzbeck A, Ritz E. Nephrol Dial Transplant; 1995 Nov 23; 10(11):2141-3. PubMed ID: 8643187 [No Abstract] [Full Text] [Related]
19. Advantages of new hemodialysis membranes and equipment. Vanholder R, Glorieux G, Van Biesen W. Nephron Clin Pract; 2010 Nov 23; 114(3):c165-72. PubMed ID: 19955821 [Abstract] [Full Text] [Related]
20. Complement activation is influenced by the membrane material, design of the dialyser, sterilizing method, and type of dialysate. Lundberg L, Johansson G, Karlsson L, Stegmayr BG. Nephrol Dial Transplant; 1994 Nov 23; 9(9):1310-4. PubMed ID: 7816297 [Abstract] [Full Text] [Related] Page: [Next] [New Search]