These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


222 related items for PubMed ID: 25761581

  • 1. Modern disposable hydrogel contact lens removal has a minimal effect on intraocular pressure.
    Hamilton-Maxwell K, King N.
    Ophthalmic Physiol Opt; 2015 Mar; 35(2):231-5. PubMed ID: 25761581
    [Abstract] [Full Text] [Related]

  • 2. Applanation tonometry in silicone hydrogel contact lens wearers.
    Allen RJ, Dev Borman A, Saleh GM.
    Cont Lens Anterior Eye; 2007 Dec; 30(5):267-9. PubMed ID: 17382579
    [Abstract] [Full Text] [Related]

  • 3. The influence of lens power and center thickness on the intraocular pressure measured through soft lenses: a comparison of two noncontact tonometers.
    Ogbuehi KC.
    Cont Lens Anterior Eye; 2012 Jun; 35(3):118-28. PubMed ID: 22322110
    [Abstract] [Full Text] [Related]

  • 4. Accurate intraocular pressure measurement in contact lens wearers with normal pressures.
    Lim L, Ng TP, Tan DT.
    CLAO J; 1997 Apr; 23(2):130-3. PubMed ID: 9108980
    [Abstract] [Full Text] [Related]

  • 5. The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry.
    Zeri F, De Cusatis M, Lupelli L, Swann PG.
    J Optom; 2016 Apr; 9(3):182-8. PubMed ID: 26499996
    [Abstract] [Full Text] [Related]

  • 6. The effect of hydrogel and silicone hydrogel contact lenses on the measurement of intraocular pressure with rebound tonometry.
    Zeri F, Calcatelli P, Donini B, Lupelli L, Zarrilli L, Swann PG.
    Cont Lens Anterior Eye; 2011 Dec; 34(6):260-5. PubMed ID: 21636312
    [Abstract] [Full Text] [Related]

  • 7. Influence of lens material and intra-ocular pressure on the outcome of non-contact tonometry over soft contact lenses.
    Patel S, Stevenson G.
    Cont Lens Anterior Eye; 2009 Apr; 32(2):68-72. PubMed ID: 19195922
    [Abstract] [Full Text] [Related]

  • 8. Tonopen XL assessment of intraocular pressure through silicone hydrogel contact lenses.
    Schornack M, Rice M, Hodge D.
    Eye Contact Lens; 2012 Sep; 38(5):270-3. PubMed ID: 22810946
    [Abstract] [Full Text] [Related]

  • 9. Intraocular Pressure After 2 Hours of Small-Diameter Scleral Lens Wear.
    Nau CB, Schornack MM, McLaren JW, Sit AJ.
    Eye Contact Lens; 2016 Nov; 42(6):350-353. PubMed ID: 26629960
    [Abstract] [Full Text] [Related]

  • 10. Effect of soft contact lenses on the measurements of intraocular pressure with non-contact pneumotonometry.
    Schollmayer P, Hawlina M.
    Klin Monbl Augenheilkd; 2003 Dec; 220(12):840-2. PubMed ID: 14704940
    [Abstract] [Full Text] [Related]

  • 11. The effect of contact lens induced corneal edema on Goldmann applanation tonometry measurements.
    Hamilton KE, Pye DC, Hali A, Lin C, Kam P, Ngyuen T.
    J Glaucoma; 2007 Jan; 16(1):153-8. PubMed ID: 17224766
    [Abstract] [Full Text] [Related]

  • 12. Intraocular pressure measurement with ocular response analyzer over soft contact lens.
    Sapkota K, Franco S, Lira M.
    Cont Lens Anterior Eye; 2014 Dec; 37(6):415-9. PubMed ID: 25086831
    [Abstract] [Full Text] [Related]

  • 13. Dynamic contour tonometry over silicone hydrogel contact lens.
    Lam AK, Tse JS.
    J Optom; 2014 Dec; 7(2):91-9. PubMed ID: 24766866
    [Abstract] [Full Text] [Related]

  • 14. Goldmann applanation tonometry over daily disposable contact lens: accuracy and safety of procedure.
    Zeri F, Lupelli L, Formichella P, Masci C, Fletcher R.
    Cont Lens Anterior Eye; 2007 Sep; 30(4):233-8; quiz, 260-1. PubMed ID: 17693127
    [Abstract] [Full Text] [Related]

  • 15. [Validity and reproducibility of sensor contact lens profiles in comparison to applanation tonometry in healthy eyes].
    Faschinger C, Mossböck G, Krainz S.
    Klin Monbl Augenheilkd; 2012 Dec; 229(12):1209-14. PubMed ID: 23172649
    [Abstract] [Full Text] [Related]

  • 16. Comparison of intraocular pressure measurement with Scheimpflug-based noncontact tonometer with and without hydrogel contact lenses.
    Kumar M, Shetty R, Jayadev C, Dutta D, Nicolsan MD, Nagaraj S, Kumar RS.
    Indian J Ophthalmol; 2015 Apr; 63(4):323-6. PubMed ID: 26044471
    [Abstract] [Full Text] [Related]

  • 17. Hourly awakening vs continuous contact lens sensor measurements of 24-hour intraocular pressure: effect on sleep macrostructure and intraocular pressure rhythm.
    Aptel F, Tamisier R, Pépin JL, Mottet B, Hubanova R, Romanet JP, Chiquet C.
    JAMA Ophthalmol; 2014 Oct; 132(10):1232-8. PubMed ID: 25074578
    [Abstract] [Full Text] [Related]

  • 18. The accuracy of Goldmann applanation tonometry over silicone hydrogel contact lenses in patients with glaucoma.
    Gomes BA, Turiel P, Cavalcanti RS, Moraes HV, Santhiago MR.
    Cont Lens Anterior Eye; 2014 Aug; 37(4):297-9. PubMed ID: 24862386
    [Abstract] [Full Text] [Related]

  • 19. Comparative measurement of intraocular pressure by Icare tonometry and Airpuff tonometry in healthy subjects and patients wearing therapeutic soft contact lenses.
    Anton A, Neuburger M, Böhringer D, Jordan JF.
    Graefes Arch Clin Exp Ophthalmol; 2013 Jul; 251(7):1791-5. PubMed ID: 23532453
    [Abstract] [Full Text] [Related]

  • 20. Dynamic Contour Tonometry (DCT) over a thin daily disposable hydrogel contact lens.
    Nosch DS, Duddek AP, Herrmann D, Stuhrmann OM.
    Cont Lens Anterior Eye; 2010 Oct; 33(5):219-24. PubMed ID: 20471302
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 12.