These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


880 related items for PubMed ID: 25924031

  • 1. Concomitant Transapical Transcatheter Valve Implantations: Edwards Sapien Valve for Severe Mitral Regurgitation in a Patient with Failing Mitral Bioprostheses and JenaValve for the Treatment of Pure Aortic Regurgitation.
    Aydin U, Gul M, Aslan S, Akkaya E, Yildirim A.
    Heart Surg Forum; 2015 Apr 28; 18(2):E053-5. PubMed ID: 25924031
    [Abstract] [Full Text] [Related]

  • 2.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 3. How should I treat a severely symptomatic, high-risk female patient with degenerated mitral (Carpentier-Edwards porcine) and aortic (Sorin Mitroflow) bioprostheses?
    Berti S, Cerillo AG, Murzi M, Mariani M, Marchi F, Schäfer U, Attia R, Bapat V, Himbert D, Brochet E, Depoix JP, Nataf P, Vahanian A.
    EuroIntervention; 2015 Feb 28; 10(10):1250-2. PubMed ID: 25244311
    [No Abstract] [Full Text] [Related]

  • 4.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 5. Urgent transcatheter aortic valve replacement for severe acute aortic regurgitation following open mitral valve surgery.
    Spina R, Khalique O, Kodali S, Bapat VN.
    Catheter Cardiovasc Interv; 2019 Apr 01; 93(5):996-1001. PubMed ID: 30408318
    [Abstract] [Full Text] [Related]

  • 6. Series of transcatheter valve-in-valve implantations in high-risk patients with degenerated bioprostheses in aortic and mitral position.
    Seiffert M, Franzen O, Conradi L, Baldus S, Schirmer J, Meinertz T, Reichenspurner H, Treede H.
    Catheter Cardiovasc Interv; 2010 Oct 01; 76(4):608-15. PubMed ID: 20506236
    [Abstract] [Full Text] [Related]

  • 7. Double transcatheter valve-in-valve implantation for degenerated aortic and mitral bioprostheses.
    Faria R, Rodrigues A, Santos N, Vouga L, Gama V.
    Rev Port Cir Cardiotorac Vasc; 2013 Oct 01; 20(3):131-4. PubMed ID: 25177739
    [Abstract] [Full Text] [Related]

  • 8. Emergency transapical mitral valve-in-valve implantation for bioprosthesis failure: transapical implantation of an Edwards Sapien-XT in a dysfunctional mitral bioprosthesis in a critical patient.
    Zanobini M, Manganiello S, Bonalumi G, Biondi R, Russo M, Mapelli M, Alamanni F, Saccocci M.
    J Cardiothorac Surg; 2017 Dec 13; 12(1):114. PubMed ID: 29237501
    [Abstract] [Full Text] [Related]

  • 9.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 10. Transcatheter aortic valve implantation for treatment of failing homograft with preexisting mechanical mitral prosthesis.
    Attia R, Bapat V.
    Catheter Cardiovasc Interv; 2013 Aug 01; 82(2):324-7. PubMed ID: 22120953
    [Abstract] [Full Text] [Related]

  • 11. Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: technical considerations and results.
    Bapat V, Attia R, Redwood S, Hancock J, Wilson K, Young C, Thomas M.
    J Thorac Cardiovasc Surg; 2012 Dec 01; 144(6):1372-9; discussion 1379-80. PubMed ID: 23140962
    [Abstract] [Full Text] [Related]

  • 12. First in human implantation of the mechanical expanding Lotus® valve in degenerated surgical valves in mitral position.
    Schaefer U, Conradi L, Lubos E, Deuschl F, Schofer N, Seiffert M, Treede H, Schirmer J, Reichenspurner H, Blankenberg S.
    Catheter Cardiovasc Interv; 2015 Dec 01; 86(7):1280-6. PubMed ID: 26389782
    [Abstract] [Full Text] [Related]

  • 13. Transapical transcatheter valve-in-valve implantation for deteriorated mitral valve bioprostheses.
    Wilbring M, Alexiou K, Tugtekin SM, Sill B, Hammer P, Schmidt T, Simonis G, Matschke K, Kappert U.
    Ann Thorac Surg; 2013 Jan 01; 95(1):111-7. PubMed ID: 23063191
    [Abstract] [Full Text] [Related]

  • 14. 'Fast-implantable' aortic valve implantation and concomitant mitral procedures.
    Ferrari E, Siniscalchi G, Marinakis S, Berdajs D, von Segesser L.
    Interact Cardiovasc Thorac Surg; 2014 Oct 01; 19(4):682-4. PubMed ID: 25015540
    [Abstract] [Full Text] [Related]

  • 15. First Reported Successful Femoral Valve-in-Valve Transcatheter Aortic Valve Replacement Using the Edwards Sapien 3 Valve.
    Fournier S, Monney P, Roguelov C, Zuffi A, Iglesias JF, Qanadli SD, Courbon C, Eeckhout E, Muller O.
    J Invasive Cardiol; 2015 Oct 01; 27(10):E220-3. PubMed ID: 26429854
    [Abstract] [Full Text] [Related]

  • 16. Transcatheter aortic valve implantation of a second-generation valve for pure aortic regurgitation: procedural outcome, haemodynamic data and follow-up.
    Schlingloff F, Schäfer U, Frerker C, Schmoeckel M, Bader R.
    Interact Cardiovasc Thorac Surg; 2014 Sep 01; 19(3):388-93. PubMed ID: 24893871
    [Abstract] [Full Text] [Related]

  • 17. 5-year experience with transcatheter transapical mitral valve-in-valve implantation for bioprosthetic valve dysfunction.
    Cheung A, Webb JG, Barbanti M, Freeman M, Binder RK, Thompson C, Wood DA, Ye J.
    J Am Coll Cardiol; 2013 Apr 30; 61(17):1759-66. PubMed ID: 23500301
    [Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19. [Degenerated mitral bioprosthesis and severe aortic valve stenosis in a high-risk patient: a two-step transcatheter valve implantation].
    Santarpino G, Fischlein T, Pfeiffer S.
    G Ital Cardiol (Rome); 2012 Nov 30; 13(11):769-71. PubMed ID: 23096588
    [Abstract] [Full Text] [Related]

  • 20.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 44.