These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
326 related items for PubMed ID: 25936944
1. Unreliable patient identification warrants ABO typing at admission to check existing records before transfusion. Ferrera-Tourenc V, Lassale B, Chiaroni J, Dettori I. Transfus Clin Biol; 2015 Jun; 22(2):66-70. PubMed ID: 25936944 [Abstract] [Full Text] [Related]
2. Analysis of ABO discrepancies occurring in 35 French hospitals. Chiaroni J, Legrand D, Dettori I, Ferrera V. Transfusion; 2004 Jun; 44(6):860-4. PubMed ID: 15157252 [Abstract] [Full Text] [Related]
3. Enhanced detection of blood bank sample collection errors with a centralized patient database. MacIvor D, Triulzi DJ, Yazer MH. Transfusion; 2009 Jan; 49(1):40-3. PubMed ID: 18798804 [Abstract] [Full Text] [Related]
4. Consecutive national surveys of ABO-incompatible blood transfusion in Japan. Fujii Y, Shibata Y, Miyata S, Inaba S, Asai T, Hoshi Y, Takamatsu J, Takahashi K, Ohto H, Juji T, Sagawa K. Vox Sang; 2009 Oct; 97(3):240-6. PubMed ID: 19476605 [Abstract] [Full Text] [Related]
5. [Yes, we should keep ABO agglutination test within bedside transfusion checks]. Daurat G. Transfus Clin Biol; 2008 Nov; 15(5):322-6. PubMed ID: 18930425 [Abstract] [Full Text] [Related]
6. The immunohematologic and patient safety benefits of a centralized transfusion database. Delaney M, Dinwiddie S, Nester TN, Aubuchon JA. Transfusion; 2013 Apr; 53(4):771-6. PubMed ID: 22803792 [Abstract] [Full Text] [Related]
7. [The pretransfusion bedside agglutination test is not a "Gold Standard"]. Levy G. Transfus Clin Biol; 2008 Nov; 15(5):318-21. PubMed ID: 18930684 [Abstract] [Full Text] [Related]
8. [Prevention of ABO-incompatible transfusion]. Fujii Y. Masui; 2011 Jan; 60(1):47-54. PubMed ID: 21348250 [Abstract] [Full Text] [Related]
9. [Accidental transfusion with ABO-incompatible blood: process for analysis of the contributing causes]. Indrikovs AJ. Sangre (Barc); 1997 Jun; 42(3):205-13. PubMed ID: 9381263 [No Abstract] [Full Text] [Related]
10. [Present state of transfusion errors]. Murakami J. Rinsho Byori; 2003 Jan; 51(1):43-9. PubMed ID: 12652690 [Abstract] [Full Text] [Related]
11. Addressing sample identification errors in a multispecialty tertiary care hospital in Bangalore. Sindhulina C, Joseph NJ. Vox Sang; 2014 Aug; 107(2):153-7. PubMed ID: 24602024 [Abstract] [Full Text] [Related]
12. ABO blood group discrepancies among blood donors in Regional Blood Transfusion Centre GTB Hospital, Delhi, India. Sharma T, Garg N, Singh B. Transfus Apher Sci; 2014 Feb; 50(1):75-80. PubMed ID: 24314713 [Abstract] [Full Text] [Related]
13. Root cause analysis of non-infectious transfusion complications and the lessons learnt. Karim F, Moiz B, Shamsuddin N, Naz S, Khurshid M. Transfus Apher Sci; 2014 Feb; 50(1):111-7. PubMed ID: 24239270 [Abstract] [Full Text] [Related]
14. Failure of bedside ABO testing is still the most common cause of incorrect blood transfusion in the Barcode era. Ahrens N, Pruss A, Kiesewetter H, Salama A. Transfus Apher Sci; 2005 Aug; 33(1):25-9. PubMed ID: 15964241 [Abstract] [Full Text] [Related]
15. [Computer management to avoid errors in transfusion]. Takahashi K. Rinsho Byori; 2003 Jan; 51(1):63-70. PubMed ID: 12652693 [Abstract] [Full Text] [Related]
16. [Emergency compatible, ABO-different blood group transfusion in the operating theater: a survey in regional Japanese Society of Anesthesiologists-certified training hospitals in 2006]. Irita K, Inada E, Tsuzaki K, Inaba S, Handa M, Kino S, Mashiko K, Kubo T, Morita K. Masui; 2009 Aug; 58(8):1045-54. PubMed ID: 19702231 [Abstract] [Full Text] [Related]
17. Nearly two decades using the check-type to prevent ABO incompatible transfusions: one institution's experience. Figueroa PI, Ziman A, Wheeler C, Gornbein J, Monson M, Calhoun L. Am J Clin Pathol; 2006 Sep; 126(3):422-6. PubMed ID: 16880143 [Abstract] [Full Text] [Related]
18. Blood group discrepancies at a tertiary care centre - analysis and resolution. Kaur G, Kaur P, Basu S, Kaur R. Int J Lab Hematol; 2014 Aug; 36(4):481-7. PubMed ID: 24325154 [Abstract] [Full Text] [Related]
19. A computer-assisted transfusion management system and changed transfusion practices contribute to appropriate management of blood components. Ohsaka A, Abe K, Ohsawa T, Miyake N, Sugita S, Tojima I. Transfusion; 2008 Aug; 48(8):1730-8. PubMed ID: 18482189 [Abstract] [Full Text] [Related]