1. The effect of some instruments for prothrombin time testing on the International Sensitivity Index (ISI) of two rabbit tissue thromboplastin reagents. Poggio M, van den Besselaar AM, van der Velde EA, Bertina RM. Thromb Haemost; 1989 Nov 24; 62(3):868-74. PubMed ID: 2595661 [Abstract] [Full Text] [Related]
2. Discrepant sensitivity of thromboplastin reagents to clotting factor levels explored by the prothrombin time in patients on stable oral anticoagulant treatment: impact on the international normalized ratio system. Testa S, Morstabilini G, Fattorini A, Galli L, Denti N, D'Angelo A. Haematologica; 2002 Dec 24; 87(12):1265-73. PubMed ID: 12495900 [Abstract] [Full Text] [Related]
3. The dependence of the International Sensitivity Index on the coagulometer used to perform the prothrombin time. Ray MJ, Smith IR. Thromb Haemost; 1990 Jun 28; 63(3):424-9. PubMed ID: 2402745 [Abstract] [Full Text] [Related]
4. Multi-center study of thromboplastin calibration precision--influence of reagent species, composition, and International Sensitivity Index (ISI). van den Besselaar AM, Bertina RM. Thromb Haemost; 1993 Jan 11; 69(1):35-40. PubMed ID: 8446936 [Abstract] [Full Text] [Related]
11. The European Concerted Action on Anticoagulation (ECAA): field studies of coagulometer effects on the ISI of ECAA thromboplastins. Poller L, van den Besselaar AM, Jespersen J, Tripodi A, Houghton D. Thromb Haemost; 1998 Oct 11; 80(4):615-23. PubMed ID: 9798981 [Abstract] [Full Text] [Related]
13. The calibration of the second primary international reference preparation for thromboplastin (thromboplastin, human, plain, coded BCT/253). Thomson JM, Tomenson JA, Poller L. Thromb Haemost; 1984 Dec 29; 52(3):336-42. PubMed ID: 6531756 [Abstract] [Full Text] [Related]
16. An International Sensitivity Index (ISI) derived from patients with abnormal liver function improves agreement between INRs determined with different reagents. Sermon AM, Smith JM, Maclean R, Kitchen S. Thromb Haemost; 2010 Apr 29; 103(4):757-65. PubMed ID: 20174759 [Abstract] [Full Text] [Related]
17. Results of a multicenter study assessing the status of standardization of a recombinant thromboplastin for the control of oral anticoagulant therapy. Tripodi A, Chantarangkul V, Braga M, Poller L, ten Cate JW, van den Besselaar AM, Mannucci PM. Thromb Haemost; 1994 Aug 29; 72(2):261-7. PubMed ID: 7831663 [Abstract] [Full Text] [Related]
18. [Suggestions and propositions to resolve some issues for standardization of prothrombin time and activated partial thromboplastin time]. Kagawa K, Fukutake K. Rinsho Byori; 1999 May 29; 47(5):431-7. PubMed ID: 10375964 [Abstract] [Full Text] [Related]
19. A simplified procedure for thromboplastin calibration--the usefulness of lyophilized plasmas assessed in a collaborative study. Tripodi A, Chantarangkul V, Manotti C, Poggi M, Braga M, Akkawat B, Bucciarelli P, Mannucci PM. Thromb Haemost; 1996 Feb 29; 75(2):309-12. PubMed ID: 8815582 [Abstract] [Full Text] [Related]