These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


932 related items for PubMed ID: 26103489

  • 1. Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism.
    Ho Than MT, Munro Iii JJ, Medich DC.
    J Appl Clin Med Phys; 2015 May 08; 16(3):5270. PubMed ID: 26103489
    [Abstract] [Full Text] [Related]

  • 2. Dosimetric characterization of the GammaClip™ 169Yb low dose rate permanent implant brachytherapy source for the treatment of nonsmall cell lung cancer postwedge resection.
    Currier B, Munro JJ, Medich DC.
    Med Phys; 2013 Aug 08; 40(8):080701. PubMed ID: 23927294
    [Abstract] [Full Text] [Related]

  • 3. Monte Carlo characterization of the M-19 high dose rate Iridium-192 brachytherapy source.
    Medich DC, Munro JJ.
    Med Phys; 2007 Jun 08; 34(6):1999-2006. PubMed ID: 17654903
    [Abstract] [Full Text] [Related]

  • 4. Monte Carlo dosimetric parameter study of a new (32)P brachytherapy source.
    Wu J, Huang J, Long F, Wang C, Wu Z, Gou C.
    Br J Radiol; 2016 Jun 08; 89(1062):20150783. PubMed ID: 27042802
    [Abstract] [Full Text] [Related]

  • 5. Monte Carlo dosimetric study of best industries and Alpha Omega Ir-192 brachytherapy seeds.
    Ballester F, Granero D, Pérez-Calatayud J, Casal E, Puchades V.
    Med Phys; 2004 Dec 08; 31(12):3298-305. PubMed ID: 15651612
    [Abstract] [Full Text] [Related]

  • 6. EGSnrc-based Monte Carlo dosimetry of CSA1 and CSA2 137Cs brachytherapy source models.
    Selvam TP, Sahoo S, Vishwakarma RS.
    Med Phys; 2009 Sep 08; 36(9):3870-9. PubMed ID: 19810459
    [Abstract] [Full Text] [Related]

  • 7. Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE.
    Casado FJ, García-Pareja S, Cenizo E, Mateo B, Bodineau C, Galán P.
    Phys Med; 2010 Sep 08; 26(3):132-9. PubMed ID: 20034828
    [Abstract] [Full Text] [Related]

  • 8. Study of encapsulated 170Tm sources for their potential use in brachytherapy.
    Ballester F, Granero D, Perez-Calatayud J, Venselaar JL, Rivard MJ.
    Med Phys; 2010 Apr 08; 37(4):1629-37. PubMed ID: 20443484
    [Abstract] [Full Text] [Related]

  • 9. Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy.
    Hiatt JR, Rivard MJ, Hughes HG.
    Med Phys; 2016 Mar 08; 43(3):1119-29. PubMed ID: 26936699
    [Abstract] [Full Text] [Related]

  • 10. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.
    Ballester F, Carlsson Tedgren Å, Granero D, Haworth A, Mourtada F, Fonseca GP, Zourari K, Papagiannis P, Rivard MJ, Siebert FA, Sloboda RS, Smith RL, Thomson RM, Verhaegen F, Vijande J, Ma Y, Beaulieu L.
    Med Phys; 2015 Jun 08; 42(6):3048-61. PubMed ID: 26127057
    [Abstract] [Full Text] [Related]

  • 11.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 12. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy.
    Campos LT, de Almeida CE.
    PLoS One; 2015 Jun 08; 10(9):e0139032. PubMed ID: 26418559
    [Abstract] [Full Text] [Related]

  • 13. Monte Carlo dosimetry of a new 192Ir pulsed dose rate brachytherapy source.
    Karaiskos P, Angelopoulos A, Pantelis E, Papagiannis P, Sakelliou L, Kouwenhoven E, Baltas D.
    Med Phys; 2003 Jan 08; 30(1):9-16. PubMed ID: 12557972
    [Abstract] [Full Text] [Related]

  • 14. The use of cylindrical coordinates for treatment planning parameters of an elongated 192Ir source.
    Patel NS, Chiu-Tsao ST, Fan P, Tsao HS, Liprie SF, Harrison LB.
    Int J Radiat Oncol Biol Phys; 2001 Nov 15; 51(4):1093-102. PubMed ID: 11704334
    [Abstract] [Full Text] [Related]

  • 15. Monte carlo investigation of the dosimetric properties of the new 103Pd BrachySeedPd-103 Model Pd-1 source.
    Chan GH, Prestwich WV.
    Med Phys; 2002 Sep 15; 29(9):1984-90. PubMed ID: 12349919
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17. A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model.
    Hiatt JR, Davis SD, Rivard MJ.
    Med Phys; 2015 Jun 15; 42(6):2764-76. PubMed ID: 26127029
    [Abstract] [Full Text] [Related]

  • 18. Monte Carlo study of the dose rate distributions for the Ir2.A85-2 and Ir2.A85-1 Ir-192 afterloading sources.
    Granero D, Pérez-Calatayud J, Ballester F.
    Med Phys; 2008 Apr 15; 35(4):1280-7. PubMed ID: 18491521
    [Abstract] [Full Text] [Related]

  • 19. Monte Carlo and experimental high dose rate 192Ir brachytherapy dosimetry with microDiamond detectors.
    Rossi G, Gainey M, Thomann B, Kollefrath M, Würfel J, Allgaier B, Baltas D.
    Z Med Phys; 2019 Aug 15; 29(3):272-281. PubMed ID: 30340801
    [Abstract] [Full Text] [Related]

  • 20. The mean photon energy ĒF at the point of measurement determines the detector-specific radiation quality correction factor kQ,M in (192)Ir brachytherapy dosimetry.
    Chofor N, Harder D, Selbach HJ, Poppe B.
    Z Med Phys; 2016 Sep 15; 26(3):238-50. PubMed ID: 26387927
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 47.