These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Measurement of 25-OH-vitamin D in human serum using liquid chromatography tandem-mass spectrometry with comparison to radioimmunoassay and automated immunoassay. van den Ouweland JM, Beijers AM, Demacker PN, van Daal H. J Chromatogr B Analyt Technol Biomed Life Sci; 2010 May 01; 878(15-16):1163-8. PubMed ID: 20381436 [Abstract] [Full Text] [Related]
4. Development and validation of the simultaneous measurement of four vitamin D metabolites in serum by LC-MS/MS for clinical laboratory applications. Satoh M, Ishige T, Ogawa S, Nishimura M, Matsushita K, Higashi T, Nomura F. Anal Bioanal Chem; 2016 Nov 01; 408(27):7617-7627. PubMed ID: 27526091 [Abstract] [Full Text] [Related]
8. [Measurement of 25-hydroxyvitamin D3 in human serum by liquid chromatography-tandem mass spectrometry and the control for analytical conditions]. Zheng X, Ma A, Zhang H, Wang Z, Wang Q, Liang H. Wei Sheng Yan Jiu; 2012 May 01; 41(3):485-8, 492. PubMed ID: 23050454 [Abstract] [Full Text] [Related]
9. Comparison of serum 25-hydroxyvitamin D levels between radioimmunoassay and liquid chromatography-tandem mass spectrometry in infants and postpartum women. Hara K, Ikeda K, Koyama Y, Wada Y, Hasegawa T. J Pediatr Endocrinol Metab; 2018 Oct 25; 31(10):1105-1111. PubMed ID: 30231011 [Abstract] [Full Text] [Related]
10. Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2 - Part 1 liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays - impact of 3-epi-25-hydroxyvitamin D3 on assay performance. Wise SA, Camara JE, Burdette CQ, Hahm G, Nalin F, Kuszak AJ, Merkel J, Durazo-Arvizu RA, Williams EL, Hoofnagle AN, Ivison F, Fischer R, van den Ouweland JMW, Ho CS, Law EWK, Simard JN, Gonthier R, Holmquist B, Meadows S, Cox L, Robyak K, Creer MH, Fitzgerald R, Clarke MW, Breen N, Lukas P, Cavalier É, Sempos CT. Anal Bioanal Chem; 2022 Jan 25; 414(1):333-349. PubMed ID: 34432104 [Abstract] [Full Text] [Related]
11. LC-MS/MS reduces interference by high levels of 25(OH)D and its metabolites on measured 1,25(OH)2D. Okai GG, Cardozo KHM, Ferrer CM, Goldman MM, Clarke NJ, Vieira JGH. Steroids; 2022 Nov 25; 187():109095. PubMed ID: 35908594 [Abstract] [Full Text] [Related]
12. Development and validation of an LC-MS/MS based method for quantification of 25 hydroxyvitamin D2 and 25 hydroxyvitamin D3 in human serum and plasma. Zhang SW, Jian W, Sullivan S, Sankaran B, Edom RW, Weng N, Sharkey D. J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Jun 15; 961():62-70. PubMed ID: 24861873 [Abstract] [Full Text] [Related]
13. 25-hydroxy-Vitamin D status: limitations in comparison and clinical interpretation of serum-levels across different assay methods. Enko D, Fridrich L, Rezanka E, Stolba R, Ernst J, Wendler I, Fabian D, Hauptlorenz S, Halwachs-Baumann G. Clin Lab; 2014 Jun 15; 60(9):1541-50. PubMed ID: 25291951 [Abstract] [Full Text] [Related]
14. Differential extraction of endogenous and exogenous 25-OH-vitamin D from serum makes the accurate quantification in liquid chromatography-tandem mass spectrometry assays challenging. Lankes U, Elder PA, Lewis JG, George P. Ann Clin Biochem; 2015 Jan 15; 52(Pt 1):151-60. PubMed ID: 24714680 [Abstract] [Full Text] [Related]
15. Improved accuracy of an tandem liquid chromatography-mass spectrometry method measuring 24R,25-dihydroxyvitamin D3 and 25-hydroxyvitamin D metabolites in serum using unspiked controls and its application to determining cross-reactivity of a chemiluminescent microparticle immunoassay. Dowling KG, Hull G, Sundvall J, Lamberg-Allardt C, Cashman KD. J Chromatogr A; 2017 May 12; 1497():102-109. PubMed ID: 28372841 [Abstract] [Full Text] [Related]
16. Harmonization Study Between LC-MS/MS and Diasorin RIA for Measurement of 25-Hydroxyvitamin D Concentrations in a Large Population Survey. Berry DJ, Dutton J, Fraser WD, Järvelin MR, Hyppönen E. J Clin Lab Anal; 2017 May 12; 31(3):. PubMed ID: 27595769 [Abstract] [Full Text] [Related]
17. Reference intervals for serum 24,25-dihydroxyvitamin D and the ratio with 25-hydroxyvitamin D established using a newly developed LC-MS/MS method. Tang JCY, Nicholls H, Piec I, Washbourne CJ, Dutton JJ, Jackson S, Greeves J, Fraser WD. J Nutr Biochem; 2017 Aug 12; 46():21-29. PubMed ID: 28437713 [Abstract] [Full Text] [Related]
18. A fast and simple method for simultaneous measurements of 25(OH)D, 24,25(OH)2D and the Vitamin D Metabolite Ratio (VMR) in serum samples by LC-MS/MS. Fabregat-Cabello N, Farre-Segura J, Huyghebaert L, Peeters S, Le Goff C, Souberbielle JC, Cavalier É. Clin Chim Acta; 2017 Oct 12; 473():116-123. PubMed ID: 28842174 [Abstract] [Full Text] [Related]
19. Evaluation of a new automated assay for the measurement of circulating 1,25-dihydroxyvitamin D levels in daily practice. Hussein H, Ibrahim F, Boudou P. Clin Biochem; 2015 Nov 12; 48(16-17):1160-2. PubMed ID: 26036867 [Abstract] [Full Text] [Related]
20. Variation in clinical vitamin D status by DiaSorin Liaison and LC-MS/MS in the presence of elevated 25-OH vitamin D2. de Koning L, Al-Turkmani MR, Berg AH, Shkreta A, Law T, Kellogg MD. Clin Chim Acta; 2013 Jan 16; 415():54-8. PubMed ID: 22975531 [Abstract] [Full Text] [Related] Page: [Next] [New Search]