These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
195 related items for PubMed ID: 26209577
21. Preloaded guidewires to facilitate endovascular repair of thoracoabdominal aortic aneurysm using a physician-modified branched stent graft. Oderich GS, Mendes BC, Correa MP. J Vasc Surg; 2014 Apr; 59(4):1168-73. PubMed ID: 24268717 [Abstract] [Full Text] [Related]
22. Endovascular repair of thoracoabdominal aortic aneurysms with a novel multibranch stent-graft design: preliminary experience. Kinstner C, Teufelsbauer H, Neumayer C, Domenig C, Wressnegger A, Wolf F, Funovics M. J Cardiovasc Surg (Torino); 2014 Aug; 55(4):543-50. PubMed ID: 25008061 [Abstract] [Full Text] [Related]
23. Prognostic factors for aorta remodeling after thoracic endovascular aortic repair of complicated chronic DeBakey IIIb aneurysms. Song SW, Kim TH, Lim SH, Lee KH, Yoo KJ, Cho BK. J Thorac Cardiovasc Surg; 2014 Sep; 148(3):925-32, 933.e1; discussion 932-3. PubMed ID: 24952822 [Abstract] [Full Text] [Related]
24. The hemodynamic impact of misalignment of fenestrated endografts: a computational study. Georgakarakos E, Xenakis A, Georgiadis GS, Argyriou C, Antoniou GA, Schoretsanitis N, Lazarides MK. Eur J Vasc Endovasc Surg; 2014 Feb; 47(2):151-9. PubMed ID: 24183244 [Abstract] [Full Text] [Related]
25. Status of Branched Grafts for Thoracic Aortic Arch Endovascular Repair. Anthony Lee W. Semin Vasc Surg; 2016 Mar; 29(1-2):84-89. PubMed ID: 27823595 [Abstract] [Full Text] [Related]
26. Branched endografts for thoracoabdominal aneurysms. Greenberg R, Eagleton M, Mastracci T. J Thorac Cardiovasc Surg; 2010 Dec; 140(6 Suppl):S171-8. PubMed ID: 21092788 [Abstract] [Full Text] [Related]
27. Radial forces of stents used in thoracic endovascular aortic repair and bare self-expanding nitinol stents measured ex vivo - Rapid rescue for obstruction of the innominate artery using bare self-expanding nitinol stents. Matsumoto T, Inoue K, Tanaka S, Aoyagi Y, Matsubara Y, Matsuda D, Yoshiya K, Yoshiga R, Ohkusa T, Maehara Y. Vascular; 2017 Feb; 25(1):36-41. PubMed ID: 26993143 [Abstract] [Full Text] [Related]
28. Effect of a Flared Renal Stent on the Performance of Fenestrated Stent-Grafts at Rest and Exercise Conditions. Kandail H, Hamady M, Xu XY. J Endovasc Ther; 2016 Oct; 23(5):809-20. PubMed ID: 27225213 [Abstract] [Full Text] [Related]
29. Hemodynamic analysis of a novel stent graft design with slit perforations in thoracic aortic aneurysm. Ong C, Xiong F, Kabinejadian F, Praveen Kumar G, Cui F, Chen G, Ho P, Leo H. J Biomech; 2019 Mar 06; 85():210-217. PubMed ID: 30704763 [Abstract] [Full Text] [Related]
30. Stenting complex aorta aneurysms with the Cardiatis multilayer flow modulator: first impressions. Debing E, Aerden D, Gallala S, Vandenbroucke F, Van den Brande P. Eur J Vasc Endovasc Surg; 2014 Jun 06; 47(6):604-8. PubMed ID: 24703008 [Abstract] [Full Text] [Related]
31. Development of Collaterals to the Spinal Cord after Endovascular Stent Graft Repair of Thoracic Aneurysms. Fukui S, Tanaka H, Kobayashi K, Kajiyama T, Mitsuno M, Yamamura M, Ryomoto M, Miyamoto Y. Eur J Vasc Endovasc Surg; 2016 Dec 06; 52(6):801-807. PubMed ID: 27776939 [Abstract] [Full Text] [Related]
32. Total debranching thoracic endovascular aortic arch repair with inflow from the descending thoracic aorta. Iida Y, Ito T, Misumi T, Shimizu H. J Vasc Surg; 2016 Feb 06; 63(2):527-8. PubMed ID: 26804219 [No Abstract] [Full Text] [Related]
33. Computational fluid dynamic analysis of the effect of morphologic features on distraction forces in fenestrated stent grafts. Jones SM, Poole RJ, How TV, Williams RL, McWilliams RG, Brennan JA, Vallabhaneni SR, Fisher RK. J Vasc Surg; 2014 Dec 06; 60(6):1648-56.e1. PubMed ID: 25454107 [Abstract] [Full Text] [Related]
34. Aortic arch and descending thoracic aortic saccular aneurysms treatment with fenestrated endograft and chimney technique for aortic branch rescue. Kasemi H, Marino M, Di Angelo CL, Fadda GF, Speziale F. Ann Vasc Surg; 2015 Jan 06; 29(1):126.e15-9. PubMed ID: 25304906 [Abstract] [Full Text] [Related]
35. Complete Antegrade Transapical Deployment of a Branched Aortic Arch Endograft: A Porcine Feasibility Study. Wipper S, Lohrenz C, Kersten JF, Akkra MM, Tsilimparis N, Detter C, von Kodolitsch Y, Larena-Avellaneda A, Debus ES, Kölbel T. J Endovasc Ther; 2016 Jun 06; 23(3):493-500. PubMed ID: 27090167 [Abstract] [Full Text] [Related]
36. Hybrid one-stage repair using a sutureless telescoped stent graft fixation for ruptured multiple thoracic aortic aneurysms. Kamohara K, Tanaka A, Itoh M, Morokuma H, Furukawa K, Morita S. Ann Thorac Cardiovasc Surg; 2014 Jun 06; 20 Suppl():918-21. PubMed ID: 24492170 [Abstract] [Full Text] [Related]
37. Flow-diverting stents for the treatment of arterial aneurysms. Sfyroeras GS, Dalainas I, Giannakopoulos TG, Antonopoulos K, Kakisis JD, Liapis CD. J Vasc Surg; 2012 Sep 06; 56(3):839-46. PubMed ID: 22840737 [Abstract] [Full Text] [Related]
38. Geometry and respiratory-induced deformation of abdominal branch vessels and stents after complex endovascular aneurysm repair. Ullery BW, Suh GY, Lee JT, Liu B, Stineman R, Dalman RL, Cheng CP. J Vasc Surg; 2015 Apr 06; 61(4):875-84. PubMed ID: 25601499 [Abstract] [Full Text] [Related]
39. Comparison of Blood Flow in Branched and Fenestrated Stent-Grafts for Endovascular Repair of Abdominal Aortic Aneurysms. Kandail H, Hamady M, Xu XY. J Endovasc Ther; 2015 Aug 06; 22(4):578-90. PubMed ID: 25979146 [Abstract] [Full Text] [Related]
40. Endovascular repair of aortic coarctation pseudoaneurysm using an off-label "hourglass" stent-graft configuration. Erben Y, Oderich GS, Duncan AA. J Endovasc Ther; 2015 Jun 06; 22(3):460-5. PubMed ID: 25878022 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]