These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


95 related items for PubMed ID: 26305085

  • 1. Low Oxygen Affinity Variant Haemoglobin in an elderly woman presenting with low oxygen saturation.
    Igbineweka NE, Horne GA, Jackson MB, Chevassut TJ.
    Acute Med; 2015; 14(2):72-6. PubMed ID: 26305085
    [Abstract] [Full Text] [Related]

  • 2. Oxygen saturation in pulse oximetry in hemoglobin anomalies.
    Zur B, Bagci S, Ludwig M, Stoffel-Wagner B.
    Klin Padiatr; 2012 Jul; 224(4):259-65. PubMed ID: 22815129
    [Abstract] [Full Text] [Related]

  • 3. Decreased oxygen saturation as a result of haemoglobin Titusville.
    Avellan-Hietanen H, Aittomaki J, Ekroos H, Aittomäki K, Turpeinen U, Kalkkinen N, Sovijärvi A.
    Clin Respir J; 2008 Oct; 2(4):242-4. PubMed ID: 20298341
    [Abstract] [Full Text] [Related]

  • 4. A novel hemoglobin, Bonn, causes falsely decreased oxygen saturation measurements in pulse oximetry.
    Zur B, Hornung A, Breuer J, Doll U, Bernhardt C, Ludwig M, Stoffel-Wagner B.
    Clin Chem; 2008 Mar; 54(3):594-6. PubMed ID: 18310146
    [Abstract] [Full Text] [Related]

  • 5. Dyshemoglobinemias and pulse oximetry: a therapeutic challenge.
    Hladik A, Lynshue K.
    J Pediatr Hematol Oncol; 2008 Nov; 30(11):850-2. PubMed ID: 18989162
    [Abstract] [Full Text] [Related]

  • 6. Pulse oximetry error in a patient with a Santa Ana haemoglobinopathy.
    Robertson A, Rahemtulla A.
    BMJ Case Rep; 2016 Sep 06; 2016():. PubMed ID: 27599809
    [Abstract] [Full Text] [Related]

  • 7. Low oxygen saturation by pulse oximetry may be associated with a low oxygen affinity hemoglobin variant, hemoglobin Titusville.
    Deyell R, Jackson S, Spier S, Le D, Poon MC.
    J Pediatr Hematol Oncol; 2006 Feb 06; 28(2):100-2. PubMed ID: 16462584
    [Abstract] [Full Text] [Related]

  • 8. Low SpO2 With Normal SaO2 During General Anesthesia: A Case Report.
    Brugger S, Santafé-Marti MD, Lakhal M.
    A A Case Rep; 2017 Oct 01; 9(7):197-198. PubMed ID: 28542050
    [Abstract] [Full Text] [Related]

  • 9. Oxygen Saturation of 75%, but No Symptoms!
    Guler S, Brunner-Agten S, Bartenstein S, Bettschen HU, Geiser T, Keller P, Funke M.
    Respiration; 2016 Oct 01; 92(6):420-424. PubMed ID: 27760425
    [No Abstract] [Full Text] [Related]

  • 10. Accuracy of pulse oximetry in the intensive care unit.
    Van de Louw A, Cracco C, Cerf C, Harf A, Duvaldestin P, Lemaire F, Brochard L.
    Intensive Care Med; 2001 Oct 01; 27(10):1606-13. PubMed ID: 11685301
    [Abstract] [Full Text] [Related]

  • 11. Hb Grove City [β38(C4)Thr→Ser, ACC>AGC; HBB: c.116C>G]: a new low oxygen affinity β chain variant.
    Taliercio RM, Ashton RW, Horwitz L, Swanson KC, Wendt PC, Hoyer JD, Oliveira JL.
    Hemoglobin; 2013 Oct 01; 37(4):396-403. PubMed ID: 23651408
    [Abstract] [Full Text] [Related]

  • 12. Diagnosis and clinical presentation of hemoglobin Kirksey.
    Hitaka D, Arai J.
    Pediatr Int; 2016 Mar 01; 58(3):235-237. PubMed ID: 26678362
    [Abstract] [Full Text] [Related]

  • 13. Haemoglobin Bonn in a Chinese family as a cause of spurious hypoxaemia measured by pulse oximetry.
    So CC, Chan AY, Chow EY, Lin SY, Yip SF, Szeto SC, Chan LC.
    J Clin Pathol; 2010 Oct 01; 63(10):947-9. PubMed ID: 20876330
    [Abstract] [Full Text] [Related]

  • 14. Haemoglobin Hammersmith precludes monitoring with conventional pulse oximetry.
    Lang SA, Chang PC, Laxdal VA, Huisman TH.
    Can J Anaesth; 1994 Oct 01; 41(10):965-8. PubMed ID: 8001215
    [Abstract] [Full Text] [Related]

  • 15. A family of three with haemoglobin Cheverly: low oxygen saturation in stable patients.
    Chow LC, Puah SH, Tiong XT, Aloysious NS, Leong TS, Chew LP.
    J R Coll Physicians Edinb; 2021 Sep 01; 51(3):253-256. PubMed ID: 34528613
    [Abstract] [Full Text] [Related]

  • 16. Hb Grifton [α87(F8)His→Pro; HBA1: C.263A > C (or HBA2)] Causes Abnormal Pulse Oximetry Measurements.
    Waters AM, Caboot JB, Verhovsek MM, Harper DP, Forouhar MA.
    Hemoglobin; 2016 Aug 01; 40(4):257-9. PubMed ID: 27225845
    [Abstract] [Full Text] [Related]

  • 17. First Family Case of Hemoglobinopathy Titusville in China with Falsely Low SpO2 and Unmeasurable SaO2.
    Chen YX, He JJ, Yu YY, Dai W, Zhang G.
    Clin Lab; 2024 Mar 01; 70(3):. PubMed ID: 38469764
    [Abstract] [Full Text] [Related]

  • 18. Hemoglobin Bassett produces low pulse oximeter and co-oximeter readings.
    Das A, Sinha S, Hoyer JD.
    Chest; 2007 Apr 01; 131(4):1242-4. PubMed ID: 17426236
    [Abstract] [Full Text] [Related]

  • 19. Validity of pulse oximetry in detection of hypoxaemia in children: comparison of ear, thumb and toe probe placements.
    Bilan N, Behbahan AG, Abdinia B, Mahallei M.
    East Mediterr Health J; 2010 Feb 01; 16(2):218-22. PubMed ID: 20799578
    [Abstract] [Full Text] [Related]

  • 20. [Arterial blood gas analysis, pulse oximeter].
    Homma T.
    Nihon Rinsho; 2011 Oct 01; 69(10):1797-801. PubMed ID: 22073576
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 5.