These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
144 related items for PubMed ID: 26557672
1. Analysis of Hereditary Elliptocytosis with Decreased Binding of Eosin-5-maleimide to Red Blood Cells. Suemori S, Wada H, Nakanishi H, Tsujioka T, Sugihara T, Tohyama K. Biomed Res Int; 2015; 2015():451861. PubMed ID: 26557672 [Abstract] [Full Text] [Related]
2. Detection of hereditary pyropoikilocytosis by the eosin-5-maleimide (EMA)-binding test is attributable to a marked reduction in EMA-reactive transmembrane proteins. King MJ, Jepson MA, Guest A, Mushens R. Int J Lab Hematol; 2011 Apr; 33(2):205-11. PubMed ID: 21054813 [Abstract] [Full Text] [Related]
3. Rapid flow cytometric test using eosin-5-maleimide for diagnosis of red blood cell membrane disorders. Tachavanich K, Tanphaichitr VS, Utto W, Viprakasit V. Southeast Asian J Trop Med Public Health; 2009 May; 40(3):570-5. PubMed ID: 19842445 [Abstract] [Full Text] [Related]
6. Flow cytometric osmotic fragility test and eosin-5'-maleimide dye-binding tests are better than conventional osmotic fragility tests for the diagnosis of hereditary spherocytosis. Arora RD, Dass J, Maydeo S, Arya V, Radhakrishnan N, Sachdeva A, Kotwal J, Bhargava M. Int J Lab Hematol; 2018 Jun; 40(3):335-342. PubMed ID: 29573337 [Abstract] [Full Text] [Related]
7. Toward the harmonization of result presentation for the eosin-5'-maleimide binding test in the diagnosis of hereditary spherocytosis. Hunt L, Greenwood D, Heimpel H, Noel N, Whiteway A, King MJ. Cytometry B Clin Cytom; 2015 Jan; 88(1):50-7. PubMed ID: 25227211 [Abstract] [Full Text] [Related]
10. A comparative evaluation of Eosin-5'-maleimide flow cytometry reveals a high diagnostic efficacy for hereditary spherocytosis. Joshi P, Aggarwal A, Jamwal M, Sachdeva MU, Bansal D, Malhotra P, Sharma P, Das R. Int J Lab Hematol; 2016 Oct; 38(5):520-6. PubMed ID: 27339613 [Abstract] [Full Text] [Related]
11. Mean corpuscular volume of control red blood cells determines the interpretation of eosin-5'-maleimide (EMA) test result in infants aged less than 6 months. Ciepiela O, Adamowicz-Salach A, Bystrzycka W, Łukasik J, Kotuła I. Ann Hematol; 2015 Aug; 94(8):1277-83. PubMed ID: 25907377 [Abstract] [Full Text] [Related]
16. Improved harmonization of eosin-5-maleimide binding test across different instruments and age groups. Agarwal AM, Liew MA, Nussenzveig RH, Sangle N, Heikal N, Yaish H, Christensen R. Cytometry B Clin Cytom; 2016 Nov; 90(6):512-516. PubMed ID: 26384602 [Abstract] [Full Text] [Related]