21. A comparative study of the measurement of mean arterial blood pressure using automatic oscillometers, arterial cannulation and auscultation. Rutten AJ, Ilsley AH, Skowronski GA, Runciman WB. Anaesth Intensive Care; 1986 Feb; 14(1):58-65. PubMed ID: 3954015 [Abstract] [Full Text] [Related]
22. Improving the quality and accuracy of non-invasive blood pressure measurement by visual inspection and automated signal processing of the Korotkoff sounds. Celler BG, Le P, Basilakis J, Ambikairajah E. Physiol Meas; 2017 Jun; 38(6):1006-1022. PubMed ID: 28471753 [Abstract] [Full Text] [Related]
23. Influence of different presentations of oscillometric data on automatic determination of systolic and diastolic pressures. Jazbinsek V, Luznik J, Mieke S, Trontelj Z. Ann Biomed Eng; 2010 Mar; 38(3):774-87. PubMed ID: 19953320 [Abstract] [Full Text] [Related]
24. Random zero sphygmomanometer versus automatic oscillometric blood pressure monitor; is either the instrument of choice? Goonasekera CD, Dillon MJ. J Hum Hypertens; 1995 Nov; 9(11):885-9. PubMed ID: 8583467 [Abstract] [Full Text] [Related]
25. Oscillometric blood pressure measurement: the methodology, some observations, and suggestions. Jilek J, Fukushima T. Biomed Instrum Technol; 2005 Nov; 39(3):237-41. PubMed ID: 15915608 [Abstract] [Full Text] [Related]
26. [Errors in blood pressure measuring with modern automated machines. Effects of errors in non-invasive oscillometric blood pressure measuring]. Forstner K. Fortschr Med; 1999 Apr 10; 117(10):22-5. PubMed ID: 10384743 [Abstract] [Full Text] [Related]
27. New Perspectives on Non-invasive Blood Pressure Measurement. Argha A, Celler BG, Yong A, Rubenis I, Butlin M, Avolio A. Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul 10; 2023():1-4. PubMed ID: 38082761 [Abstract] [Full Text] [Related]
29. Comparison of auscultatory and oscillometric blood pressures. Park MK, Menard SW, Yuan C. Arch Pediatr Adolesc Med; 2001 Jan 10; 155(1):50-3. PubMed ID: 11177062 [Abstract] [Full Text] [Related]
30. Oscillometric blood pressure: a review for clinicians. Alpert BS, Quinn D, Gallick D. J Am Soc Hypertens; 2014 Dec 10; 8(12):930-8. PubMed ID: 25492837 [Abstract] [Full Text] [Related]
31. Accuracy of oscillometric devices in children and adults. Chiolero A, Paradis G, Lambert M. Blood Press; 2010 Aug 10; 19(4):254-9. PubMed ID: 20156034 [Abstract] [Full Text] [Related]
32. Single cuff comparison of two methods for indirect measurement of arterial blood pressure: standard auscultatory method versus automatic oscillometric method. Pessenhofer H. Basic Res Cardiol; 1986 Aug 10; 81(1):101-9. PubMed ID: 3718426 [Abstract] [Full Text] [Related]
33. Novel methods of testing and calibration of oscillometric blood pressure monitors. Celler BG, Argha A, Le PN, Ambikairajah E. PLoS One; 2018 Aug 10; 13(8):e0201123. PubMed ID: 30080862 [Abstract] [Full Text] [Related]
34. Oscillometric blood pressure measurement: description of the method used. Wonka F. Z Kardiol; 1996 Aug 10; 85 Suppl 3():1-7. PubMed ID: 8896292 [Abstract] [Full Text] [Related]
35. Blood pressure measurement: retrospective and prospective views. Smulyan H, Safar ME. Am J Hypertens; 2011 Jun 10; 24(6):628-34. PubMed ID: 21350431 [Abstract] [Full Text] [Related]
36. A study for the development of K-sound based automatic blood pressure device using PVDF film. Xiong Li, Panicker GV, Im JJ. Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug 10; 2016():255-258. PubMed ID: 28268325 [Abstract] [Full Text] [Related]
37. Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations. Gravlee GP, Brockschmidt JK. J Clin Monit; 1990 Oct 10; 6(4):284-98. PubMed ID: 2230858 [Abstract] [Full Text] [Related]
38. Biases in the measurement of arterial pressure. Finnie KJ, Watts DG, Armstrong PW. Crit Care Med; 1984 Nov 10; 12(11):965-8. PubMed ID: 6499482 [Abstract] [Full Text] [Related]
39. Oscillometric estimation of central blood pressure: validation of the Mobil-O-Graph in comparison with the SphygmoCor device. Weiss W, Gohlisch C, Harsch-Gladisch C, Tölle M, Zidek W, van der Giet M. Blood Press Monit; 2012 Jun 10; 17(3):128-31. PubMed ID: 22561735 [Abstract] [Full Text] [Related]
40. Korotkoff sound versus oscillometric cuff sphygmomanometers: comparison between auscultatory and DynaPulse blood pressure measurements. Chio SS, Urbina EM, Lapointe J, Tsai J, Berenson GS. J Am Soc Hypertens; 2011 Jun 10; 5(1):12-20. PubMed ID: 21269907 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]