These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


330 related items for PubMed ID: 26641026

  • 21. A comparative study of the measurement of mean arterial blood pressure using automatic oscillometers, arterial cannulation and auscultation.
    Rutten AJ, Ilsley AH, Skowronski GA, Runciman WB.
    Anaesth Intensive Care; 1986 Feb; 14(1):58-65. PubMed ID: 3954015
    [Abstract] [Full Text] [Related]

  • 22. Improving the quality and accuracy of non-invasive blood pressure measurement by visual inspection and automated signal processing of the Korotkoff sounds.
    Celler BG, Le P, Basilakis J, Ambikairajah E.
    Physiol Meas; 2017 Jun; 38(6):1006-1022. PubMed ID: 28471753
    [Abstract] [Full Text] [Related]

  • 23. Influence of different presentations of oscillometric data on automatic determination of systolic and diastolic pressures.
    Jazbinsek V, Luznik J, Mieke S, Trontelj Z.
    Ann Biomed Eng; 2010 Mar; 38(3):774-87. PubMed ID: 19953320
    [Abstract] [Full Text] [Related]

  • 24. Random zero sphygmomanometer versus automatic oscillometric blood pressure monitor; is either the instrument of choice?
    Goonasekera CD, Dillon MJ.
    J Hum Hypertens; 1995 Nov; 9(11):885-9. PubMed ID: 8583467
    [Abstract] [Full Text] [Related]

  • 25. Oscillometric blood pressure measurement: the methodology, some observations, and suggestions.
    Jilek J, Fukushima T.
    Biomed Instrum Technol; 2005 Nov; 39(3):237-41. PubMed ID: 15915608
    [Abstract] [Full Text] [Related]

  • 26. [Errors in blood pressure measuring with modern automated machines. Effects of errors in non-invasive oscillometric blood pressure measuring].
    Forstner K.
    Fortschr Med; 1999 Apr 10; 117(10):22-5. PubMed ID: 10384743
    [Abstract] [Full Text] [Related]

  • 27. New Perspectives on Non-invasive Blood Pressure Measurement.
    Argha A, Celler BG, Yong A, Rubenis I, Butlin M, Avolio A.
    Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul 10; 2023():1-4. PubMed ID: 38082761
    [Abstract] [Full Text] [Related]

  • 28. Perioperative Noninvasive Blood Pressure Monitoring.
    Kuck K, Baker PD.
    Anesth Analg; 2018 Aug 10; 127(2):408-411. PubMed ID: 29189276
    [Abstract] [Full Text] [Related]

  • 29. Comparison of auscultatory and oscillometric blood pressures.
    Park MK, Menard SW, Yuan C.
    Arch Pediatr Adolesc Med; 2001 Jan 10; 155(1):50-3. PubMed ID: 11177062
    [Abstract] [Full Text] [Related]

  • 30. Oscillometric blood pressure: a review for clinicians.
    Alpert BS, Quinn D, Gallick D.
    J Am Soc Hypertens; 2014 Dec 10; 8(12):930-8. PubMed ID: 25492837
    [Abstract] [Full Text] [Related]

  • 31. Accuracy of oscillometric devices in children and adults.
    Chiolero A, Paradis G, Lambert M.
    Blood Press; 2010 Aug 10; 19(4):254-9. PubMed ID: 20156034
    [Abstract] [Full Text] [Related]

  • 32. Single cuff comparison of two methods for indirect measurement of arterial blood pressure: standard auscultatory method versus automatic oscillometric method.
    Pessenhofer H.
    Basic Res Cardiol; 1986 Aug 10; 81(1):101-9. PubMed ID: 3718426
    [Abstract] [Full Text] [Related]

  • 33. Novel methods of testing and calibration of oscillometric blood pressure monitors.
    Celler BG, Argha A, Le PN, Ambikairajah E.
    PLoS One; 2018 Aug 10; 13(8):e0201123. PubMed ID: 30080862
    [Abstract] [Full Text] [Related]

  • 34. Oscillometric blood pressure measurement: description of the method used.
    Wonka F.
    Z Kardiol; 1996 Aug 10; 85 Suppl 3():1-7. PubMed ID: 8896292
    [Abstract] [Full Text] [Related]

  • 35. Blood pressure measurement: retrospective and prospective views.
    Smulyan H, Safar ME.
    Am J Hypertens; 2011 Jun 10; 24(6):628-34. PubMed ID: 21350431
    [Abstract] [Full Text] [Related]

  • 36. A study for the development of K-sound based automatic blood pressure device using PVDF film.
    Xiong Li, Panicker GV, Im JJ.
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug 10; 2016():255-258. PubMed ID: 28268325
    [Abstract] [Full Text] [Related]

  • 37. Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations.
    Gravlee GP, Brockschmidt JK.
    J Clin Monit; 1990 Oct 10; 6(4):284-98. PubMed ID: 2230858
    [Abstract] [Full Text] [Related]

  • 38. Biases in the measurement of arterial pressure.
    Finnie KJ, Watts DG, Armstrong PW.
    Crit Care Med; 1984 Nov 10; 12(11):965-8. PubMed ID: 6499482
    [Abstract] [Full Text] [Related]

  • 39. Oscillometric estimation of central blood pressure: validation of the Mobil-O-Graph in comparison with the SphygmoCor device.
    Weiss W, Gohlisch C, Harsch-Gladisch C, Tölle M, Zidek W, van der Giet M.
    Blood Press Monit; 2012 Jun 10; 17(3):128-31. PubMed ID: 22561735
    [Abstract] [Full Text] [Related]

  • 40. Korotkoff sound versus oscillometric cuff sphygmomanometers: comparison between auscultatory and DynaPulse blood pressure measurements.
    Chio SS, Urbina EM, Lapointe J, Tsai J, Berenson GS.
    J Am Soc Hypertens; 2011 Jun 10; 5(1):12-20. PubMed ID: 21269907
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 17.