These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


225 related items for PubMed ID: 26684022

  • 1. 25-Hydroxyvitamin D C3-epimer is universally present in neonatal Western Australian samples but is unlikely to contribute to diagnostic misclassification.
    Cooke DJ, Cooke BR, Bell DA, Vasikaran SD, Glendenning P.
    Ann Clin Biochem; 2016 Sep; 53(Pt 5):593-8. PubMed ID: 26684022
    [Abstract] [Full Text] [Related]

  • 2. Maternal-fetal-infant dynamics of the C3-epimer of 25-hydroxyvitamin D.
    Bailey D, Perumal N, Yazdanpanah M, Al Mahmud A, Baqui AH, Adeli K, Roth DE.
    Clin Biochem; 2014 Jun; 47(9):816-22. PubMed ID: 24462965
    [Abstract] [Full Text] [Related]

  • 3.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 4.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 5. Analytical measurement of serum 25-OH-vitamin D₃, 25-OH-vitamin D₂ and their C3-epimers by LC-MS/MS in infant and pediatric specimens.
    Yazdanpanah M, Bailey D, Walsh W, Wan B, Adeli K.
    Clin Biochem; 2013 Sep; 46(13-14):1264-71. PubMed ID: 23269360
    [Abstract] [Full Text] [Related]

  • 6.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 7.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 8. S-25-hydroxyvitamin D and C3-epimers in pregnancy and infancy: An Odense Child Cohort study.
    Mydtskov ND, Lykkedegn S, Fruekilde PBN, Nielsen J, Barington T, Christesen HT.
    Clin Biochem; 2017 Dec; 50(18):988-996. PubMed ID: 28697996
    [Abstract] [Full Text] [Related]

  • 9. Plasma 3-Epi-25-Hydroxycholecalciferol Can Alter the Assessment of Vitamin D Status Using the Current Reference Ranges for Pregnant Women and Their Newborns.
    Aghajafari F, Field CJ, Rabi D, Kaplan BJ, Maggiore JA, O'Beirne M, Hanley DA, Eliasziw M, Dewey D, Ross S, APrON Study Team.
    J Nutr; 2016 Jan; 146(1):70-5. PubMed ID: 26609169
    [Abstract] [Full Text] [Related]

  • 10. Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in LC-MS/MS methods not separating both metabolites as determined by an LC-MS/MS method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum.
    van den Ouweland JM, Beijers AM, van Daal H.
    J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Sep 15; 967():195-202. PubMed ID: 25125396
    [Abstract] [Full Text] [Related]

  • 11. Evaluation of vitamin D storage in patients with chronic kidney disease: Detection of serum vitamin D metabolites using high performance liquid chromatography-tandem mass spectrometry.
    Li YM, Feng Q, Jiang WQ, Wu BT, Feng JF.
    J Steroid Biochem Mol Biol; 2021 Jun 15; 210():105860. PubMed ID: 33662569
    [Abstract] [Full Text] [Related]

  • 12. Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2 - Part 1 liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays - impact of 3-epi-25-hydroxyvitamin D3 on assay performance.
    Wise SA, Camara JE, Burdette CQ, Hahm G, Nalin F, Kuszak AJ, Merkel J, Durazo-Arvizu RA, Williams EL, Hoofnagle AN, Ivison F, Fischer R, van den Ouweland JMW, Ho CS, Law EWK, Simard JN, Gonthier R, Holmquist B, Meadows S, Cox L, Robyak K, Creer MH, Fitzgerald R, Clarke MW, Breen N, Lukas P, Cavalier É, Sempos CT.
    Anal Bioanal Chem; 2022 Jan 15; 414(1):333-349. PubMed ID: 34432104
    [Abstract] [Full Text] [Related]

  • 13. Gestational vitamin D3 supplementation and sun exposure significantly influence cord blood vitamin D status and 3-epi-25-hydroxyvitamin D3 levels in term newborns.
    Vierucci F, Fusani L, Saba A, Minucciani T, Belluomini MP, Domenici R, Bracco GL, Vaccaro A, Federico G.
    Clin Chim Acta; 2022 Jan 01; 524():59-68. PubMed ID: 34838794
    [Abstract] [Full Text] [Related]

  • 14. Methodological issues in assessing plasma 25-hydroxyvitamin D concentration in newborn infants.
    Gallo S, Comeau K, Agellon S, Vanstone C, Sharma A, Jones G, L'abbé M, Khamessan A, Weiler H, Rodd C.
    Bone; 2014 Apr 01; 61():186-90. PubMed ID: 24473373
    [Abstract] [Full Text] [Related]

  • 15. C3-epimerization of 25-hydroxyvitamin D increases with increasing serum 25-hydroxyvitamin D levels and shows a high degree of tracking over time.
    Kubiak JM, Grimnes G, Cashman KD, Kamycheva E, Dowling K, Skrabáková Z, Jorde R.
    Clin Biochem; 2018 Apr 01; 54():61-67. PubMed ID: 29476721
    [Abstract] [Full Text] [Related]

  • 16. The Impact of Sample Type on Vitamin D Quantification and Clinical Classification during Pregnancy.
    Harvey SM, Murphy VE, Gibson PG, Clarke M, Jensen ME.
    Nutrients; 2020 Dec 18; 12(12):. PubMed ID: 33352934
    [Abstract] [Full Text] [Related]

  • 17. Measurement of serum 3-epi-25-hydroxyvitamin D3, 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in infant, paediatric and adolescent populations of Korea using ultra-performance liquid chromatography-tandem mass spectrometry.
    Cho SE, Kim S, Kim YD, Lee H, Seo DH, Song J, Um TH, Cho CR, Kim NH, Hwang JH.
    Ann Clin Biochem; 2017 Sep 18; 54(5):530-538. PubMed ID: 27614352
    [Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20. Improved accuracy of an tandem liquid chromatography-mass spectrometry method measuring 24R,25-dihydroxyvitamin D3 and 25-hydroxyvitamin D metabolites in serum using unspiked controls and its application to determining cross-reactivity of a chemiluminescent microparticle immunoassay.
    Dowling KG, Hull G, Sundvall J, Lamberg-Allardt C, Cashman KD.
    J Chromatogr A; 2017 May 12; 1497():102-109. PubMed ID: 28372841
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 12.