These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
423 related items for PubMed ID: 26814079
1. [Exploratory study of 3D printing technique in the treatment of basilar invagination and atlantoaxial dislocation]. Yin Y, Yu X, Tong H, Xu T, Wang P, Qiao G. Zhonghua Yi Xue Za Zhi; 2015 Oct 06; 95(37):3004-7. PubMed ID: 26814079 [Abstract] [Full Text] [Related]
2. [Harms technique of C1-C2 fixation with polyaxial screws and rods]. Stulík J, Vyskocil T, Sebesta P, Kryl J. Acta Chir Orthop Traumatol Cech; 2005 Oct 06; 72(1):22-7. PubMed ID: 15860148 [Abstract] [Full Text] [Related]
3. Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw. Yoshida M, Neo M, Fujibayashi S, Nakamura T. Spine (Phila Pa 1976); 2006 Jul 01; 31(15):E513-7. PubMed ID: 16816753 [Abstract] [Full Text] [Related]
4. Risk of vertebral artery injury: comparison between C1-C2 transarticular and C2 pedicle screws. Yeom JS, Buchowski JM, Kim HJ, Chang BS, Lee CK, Riew KD. Spine J; 2013 Jul 01; 13(7):775-85. PubMed ID: 23684237 [Abstract] [Full Text] [Related]
5. Comparison of Outcomes Between C1-C2 Screw-Hook Fixation and C1-C2 Screw-Rod Fixation for Treating Reducible Atlantoaxial Dislocation. Ni B, Zhao W, Guo Q, Zhang M, Chen J, Guo X, Lu X, Xie N. Spine (Phila Pa 1976); 2017 Oct 15; 42(20):1587-1593. PubMed ID: 28296813 [Abstract] [Full Text] [Related]
8. Posterior C2 Fixation Using Trans-C2 Inferior Articular Process Screws: A Case Series and Technical Note. Zong R, Li T, Lu L, Qiao G, Yu X. World Neurosurg; 2019 Jan 15; 121():e70-e76. PubMed ID: 30213673 [Abstract] [Full Text] [Related]
9. Technique of C2 Subfacetal Screw in Patients with High-Riding Vertebral Artery. Salunke P, Singh A, Karthigeyan M. World Neurosurg; 2020 Dec 15; 144():59. PubMed ID: 32791217 [Abstract] [Full Text] [Related]
11. Technique of C2 Nerve Root Preservation in the Presence of Anomalous Vertebral Artery in Atlantoaxial Operations. Salunke P, Karthigeyan M, Puneeth S, Sharma A. World Neurosurg; 2023 Mar 15; 171():114. PubMed ID: 36584896 [Abstract] [Full Text] [Related]
15. [Transarticular fixation of C1-C2: a multicenter retrospective study]. Suchomel P, Stulík J, Klézl Z, Chrobok J, Lukás R, Krbec M, Magerl F. Acta Chir Orthop Traumatol Cech; 2004 Mar 15; 71(1):6-12. PubMed ID: 15069856 [Abstract] [Full Text] [Related]
16. Anatomic determination of optimal entry point and direction for C1 lateral mass screw placement. Blagg SE, Don AS, Robertson PA. J Spinal Disord Tech; 2009 Jun 15; 22(4):233-9. PubMed ID: 19494741 [Abstract] [Full Text] [Related]