These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
439 related items for PubMed ID: 26897821
1. Feasibility of Valve-in-Valve Procedure for Degenerated St. Jude Medical Trifecta Bioprosthesis. Verhoye JP, Harmouche M, Soulami RB, Thebault C, Boulmier D, Leguerrier A, Anselmi A. J Heart Valve Dis; 2015 Jul; 24(4):484-6. PubMed ID: 26897821 [Abstract] [Full Text] [Related]
4. First-in-human valve-in-valve implantation of a 20 mm balloon expandable transcatheter heart valve. Binder RK, Wood D, Webb JG, Cheung A. Catheter Cardiovasc Interv; 2013 Dec 01; 82(7):E929-31. PubMed ID: 22821872 [Abstract] [Full Text] [Related]
5. Transcarotid aortic valve-in-valve implantation for degenerated stentless aortic root conduits with severe regurgitation: a case series. Huber C, Praz F, O'Sullivan CJ, Langhammer B, Gloekler S, Stortecky S, von Allmen RS, Meier B, Carrel T, Englberger L, Windecker S, Wenaweser P. Interact Cardiovasc Thorac Surg; 2015 Jun 01; 20(6):694-700. PubMed ID: 25776924 [Abstract] [Full Text] [Related]
6. Transcatheter aortic valve implantation for treatment of patients with degenerated aortic bioprostheses--valve-in-valve technique. Gotzmann M, Mügge A, Bojara W. Catheter Cardiovasc Interv; 2010 Dec 01; 76(7):1000-6. PubMed ID: 20824744 [Abstract] [Full Text] [Related]
7. Transcatheter aortic valve-in-valve treatment of degenerative stentless supra-annular Freedom Solo valves: A single centre experience. Cockburn J, Dooley M, Parker J, Hill A, Hutchinson N, de Belder A, Trivedi U, Hildick-Smith D. Catheter Cardiovasc Interv; 2017 Feb 15; 89(3):438-444. PubMed ID: 27315455 [Abstract] [Full Text] [Related]
8. Valve-in-Valve Procedures in Failing Biological Xenografts Using a Novel Balloon-Expandable Device: Experience in Aortic, Mitral, and Tricuspid Positions. Schaefer A, Conradi L, Seiffert M, Lubos E, Blankenberg S, Reichenspurner H, Schaefer U, Treede H. Thorac Cardiovasc Surg; 2016 Aug 15; 64(5):366-73. PubMed ID: 26277078 [Abstract] [Full Text] [Related]
9. A prospective "oversizing" strategy of the Edwards SAPIEN bioprosthesis: results and impact on aortic regurgitation. Samim M, Stella PR, Agostoni P, Kluin J, Ramjankhan F, Sieswerda G, Budde R, van der Linden M, Juthier F, Banfi C, Hurt C, Samim M, Hillaert M, van Herwerden L, Bertrand ME, Doevendans PA, Van Belle E. J Thorac Cardiovasc Surg; 2013 Feb 15; 145(2):398-405. PubMed ID: 22377664 [Abstract] [Full Text] [Related]
11. Leaflet tear in a Trifecta aortic bioprosthesis 34 months after implantation. Piñón M, Durán D, Pazos P, Pradas G. Interact Cardiovasc Thorac Surg; 2015 Feb 15; 20(2):281-2. PubMed ID: 25404230 [Abstract] [Full Text] [Related]
12. Image-based decision-making treatment of degenerated mitroflow and trifecta prostheses. Van Linden A, Blumenstein J, Möllmann H, Kim WK, Walther T, Kempfert J. Ann Thorac Surg; 2014 Nov 15; 98(5):1809-13. PubMed ID: 25441789 [Abstract] [Full Text] [Related]
14. Balloon valuloplasty prior to transcatheter valve-in-valve implantation in a degenerated Mitroflow aortic bioprosthesis. Cerillo AG, Berti S, Glauber M. Catheter Cardiovasc Interv; 2013 May 15; 81(6):1075-8. PubMed ID: 22744728 [Abstract] [Full Text] [Related]
15. Transcatheter aortic and mitral valve implantation in bioprosthetic valves: When one correction is not enough. Akujuo AC, Dellis SL, Delago AJ, Bennett EV. J Thorac Cardiovasc Surg; 2015 Aug 15; 150(2):e15-7. PubMed ID: 26076999 [No Abstract] [Full Text] [Related]
16. CoreValve degeneration with severe transvalvular aortic regurgitation treated with valve-in-valve implantation. Sinning JM, Vasa-Nicotera M, Werner N, Zimmer S, Mellert F, Welz A, Grube E, Nickenig G, Hammerstingl C. JACC Cardiovasc Interv; 2014 Jul 15; 7(7):e71-2. PubMed ID: 24954574 [No Abstract] [Full Text] [Related]
17. The St Jude Medical Trifecta aortic pericardial valve: results from a global, multicenter, prospective clinical study. Bavaria JE, Desai ND, Cheung A, Petracek MR, Groh MA, Borger MA, Schaff HV. J Thorac Cardiovasc Surg; 2014 Feb 15; 147(2):590-7. PubMed ID: 23477687 [Abstract] [Full Text] [Related]
18. Transcatheter aortic valve implantation for treatment of failing homograft with preexisting mechanical mitral prosthesis. Attia R, Bapat V. Catheter Cardiovasc Interv; 2013 Aug 01; 82(2):324-7. PubMed ID: 22120953 [Abstract] [Full Text] [Related]
19. Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: technical considerations and results. Bapat V, Attia R, Redwood S, Hancock J, Wilson K, Young C, Thomas M. J Thorac Cardiovasc Surg; 2012 Dec 01; 144(6):1372-9; discussion 1379-80. PubMed ID: 23140962 [Abstract] [Full Text] [Related]
20. Transfemoral aortic valve-in-valve implantation with a balloon-expandable valve for the treatment of stentless xenograft severe aortic regurgitation. Bagur R, Rodés-Cabau J, De Larochellière R, Doyle D, Rheault M, Dumont E. JACC Cardiovasc Interv; 2011 Nov 01; 4(11):1248-9. PubMed ID: 22115667 [No Abstract] [Full Text] [Related] Page: [Next] [New Search]