These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
6. Sub-3 mm, near-200 ps TOF/DOI-PET imaging with monolithic scintillator detectors in a 70 cm diameter tomographic setup. Borghi G, Tabacchini V, Bakker R, Schaart DR. Phys Med Biol; 2018 Jul 27; 63(15):155006. PubMed ID: 29995639 [Abstract] [Full Text] [Related]
7. A thick semi-monolithic scintillator detector for clinical PET scanners. Zhang C, Wang X, Sun M, Kuang Z, Zhang X, Ren N, Wu S, Sang Z, Sun T, Hu Z, Yang Y, Liu Z. Phys Med Biol; 2021 Mar 12; 66(6):065023. PubMed ID: 33709958 [Abstract] [Full Text] [Related]
8. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs. Kuang Z, Sang Z, Wang X, Fu X, Ren N, Zhang X, Zheng Y, Yang Q, Hu Z, Du J, Liang D, Liu X, Zheng H, Yang Y. Med Phys; 2018 Feb 12; 45(2):613-621. PubMed ID: 29222959 [Abstract] [Full Text] [Related]
9. A 32 mm × 32 mm × 22 mm monolithic LYSO:Ce detector with dual-sided digital photon counter readout for ultrahigh-performance TOF-PET and TOF-PET/MRI. Borghi G, Peet BJ, Tabacchini V, Schaart DR. Phys Med Biol; 2016 Jul 07; 61(13):4929-49. PubMed ID: 27286232 [Abstract] [Full Text] [Related]
10. A Prototype High-Resolution Small-Animal PET Scanner Dedicated to Mouse Brain Imaging. Yang Y, Bec J, Zhou J, Zhang M, Judenhofer MS, Bai X, Di K, Wu Y, Rodriguez M, Dokhale P, Shah KS, Farrell R, Qi J, Cherry SR. J Nucl Med; 2016 Jul 07; 57(7):1130-5. PubMed ID: 27013696 [Abstract] [Full Text] [Related]
15. Depth-of-interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual-ended signal readout. Seo M, Park H, Lee S, Ko GB, Lee JS. Med Phys; 2023 Jul 07; 50(7):4112-4121. PubMed ID: 36907664 [Abstract] [Full Text] [Related]
17. Performance of a high-resolution depth encoding PET detector using barium sulfate reflector. Kuang Z, Wang X, Li C, Deng X, Feng K, Hu Z, Fu X, Ren N, Zhang X, Zheng Y, Liang D, Liu X, Zheng H, Yang Y. Phys Med Biol; 2017 Jul 06; 62(15):5945-5958. PubMed ID: 28682792 [Abstract] [Full Text] [Related]
18. High-resolution monolithic LYSO detector with 6-layer depth-of-interaction for clinical PET. Stockhoff M, Decuyper M, Van Holen R, Vandenberghe S. Phys Med Biol; 2021 Jul 30; 66(15):. PubMed ID: 34261049 [Abstract] [Full Text] [Related]
19. Open-field mouse brain PET: design optimisation and detector characterisation. Kyme AZ, Judenhofer MS, Gong K, Bec J, Selfridge A, Du J, Qi J, Cherry SR, Meikle SR. Phys Med Biol; 2017 Jul 13; 62(15):6207-6225. PubMed ID: 28475491 [Abstract] [Full Text] [Related]